background image

ENGINE SPECIFICATIONS

General

Cooling System

Make

Perkins

Cooling System Type

Closed Recovery

EPA Emissions Compliance

Stationary Emergency

Water Pump

Centrifugal Type, Belt-Driven

EPA Emissions Reference

See Emissions Data Sheet

Fan Type

Pusher

Cylinder #

6

Fan Speed (rpm)

1439

Type

In-Line

Fan Diameter mm (in.)

965 (38)

Displacement - L

18.13

Coolant Heater Standard Wattage

1500

Bore - mm (in.)

145(5.71)

Coolant Heater Standard Voltage

120VAC

Stroke - mm (in.)

183(7.20)

Compression Ratio

14.5:1

Fuel System

Intake Air Method

Turbocharged/Aftercooled

Fuel Type

Ultra Low Sulfur Diesel #2

Cylinder Head Type

4 Valve

Fuel Specifications

ASTM

Piston Type

Aluminum

Fuel Filtering (microns)

Primary 10 - Secondary 2

Connecting Rod Type

I-Beam Section

Fuel Injection

Electronic

Fuel Pump Type

Engine Driven Gear

Engine Governing

Injector Type

MEUI

Governor

Electronic Isochronous

Engine Type

Pre-Combustion

Frequency Regulation (Steady State)

± 0.25%

Fuel Supply Line - mm (in.)

12.7 (½"NPT)

Fuel Return Line - mm (in.)

12.7 (½"NPT)

Lubrication System

Oil Pump Type

Gear

Engine Electrical  System

Oil Filter Type

Full-Flow Cartridge

System Voltage

24VDC

Crankcase Capacity - L (Gal)

60 (15.8)

Battery Charging Alternator

70 Amps at 24V

Battery Size (at 0ºC)

1155 CCA

Battery Group

8D

Battery Voltage

(2) - 12VDC

Ground Polarity

Negative

ALTERNATOR SPECIFICATIONS

Standard Model

WEG

Voltage Regulator Type

Digital

Poles

4

Number of Sensed Phases

All

Field Type

Revolving

Regulation Accuracy (Steady State)

± 1%

Insulation Class - Rotor

H

Insulation Class - Stator

H

Total Harmonic Distortion

< 3%

Telephone Interference Factor (TIF)

< 50

Standard Excitation

Permanent Magnet

Bearings

Single Sealed Cartridge

Coupling

Direct, Flexible Disc

Load Capacity - Standby

100%

Prototype Short Circuit Test

Yes

CODES AND STANDARDS COMPLIANCE (WHERE APPLICABLE)

NFPA 99

BS5514

NFPA 110

SAE J1349

ISO 8528-5

DIN6271

ISO 1708A.5

IEEE C62.41 TESTING

ISO 3046

NEMA ICS 1

ETL certified to UL2200 Standards

2 of 4

Rating Definitions:
Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%)  
Prime – Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. (Max. load factor = 80%) A 10% overload capacity is available for 1 out of 
every 12 hours.

SD600 

application and engineering data

600 kW Diesel

Содержание SD600

Страница 1: ... COMPLIANT 4 MEETS EPA STANDARDS INDUSTRIAL TESTED GENERAC APPROVED 4 ENSURES INDUSTRIAL STANDARDS POWER MATCHED OUTPUT 4 ENGINEERED FOR PERFORMANCE INDUSTRIAL GRADE 4 IMPROVES LONGEVITY AND RELIABILITY Alternator TWO THIRDS PITCH 4 ELIMINATES HARMFUL 3RD HARMONIC LAYER WOUND ROTOR STATOR 4 IMPROVES COOLING CLASS H MATERIALS 4 HEAT TOLERANT DESIGN DIGITAL 3 PHASE VOLTAGE CONTROL 4 FAST AND ACCURAT...

Страница 2: ...pe Full Flow Cartridge System Voltage 24VDC Crankcase Capacity L Gal 60 15 8 Battery Charging Alternator 70 Amps at 24V Battery Size at 0ºC 1155 CCA Battery Group 8D Battery Voltage 2 12VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model WEG Voltage Regulator Type Digital Poles 4 Number of Sensed Phases All Field Type Revolving Regulation Accuracy Steady State 1 Insulation Class ...

Страница 3: ...3 571 857 1143 1429 1714 2000 Upsize 2 Upsize 2 Fuel Consumption Rates STANDBY Fuel Pump Lift m ft Percent Load gph lph 3 7 12 25 18 4 69 7 50 28 2 88 7 75 35 6 134 8 100 41 4 156 7 Refer to Emissions Data Sheet for maximum fuel flow for EPA and SCAQMD permitting purposes STANDBY Coolant Flow per Minute gpm lpm 114 1 432 Heat Rejection to Coolant BTU hr 1 589 760 Inlet Air cfm m3 min 30 088 852 Ma...

Страница 4: ...r Opt Remote Relay Panel 8 or 16 Opt 7 Day Programmable Exerciser Std Special Applications Programmable PLC Std RS 232 Std RS 485 Std All Phase Sensing DVR Std Full System Status Std Utility Monitoring Req H Transfer Switch Std 2 Wire Start Compatible Std Power Output kW Std Power Factor Std Reactive Power Std All phase AC Voltage Std All phase Currents Std Oil Pressure Std Coolant Temperature Std...

Страница 5: ... TANK 8 334 24 1001 24 1001 48 2002 LEVEL 1 SOUND ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 8 334 24 1001 24 1001 48 2002 LEVEL 2 SOUND ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 8 334 24 1001 24 1001 48 2002 5 of 4 SD600 enclosure and tank configurations Generac Power Systems Inc S45 W29290 HWY 59 Waukesha WI 53189 generac com 2012 Generac Power Systems Inc All rights reserve...

Отзывы: