background image

Generator image used for illustration purposes only

1 of 4

Industrial Diesel Generator Set

EPA Certified Stationary Emergency

600 kW Diesel

Standby Power Rating

750kVA    600kW    60Hz

features

benefits

primary codes and standards

Generator Set

=

  PROTOTYPE & TORSIONALLY TESTED 

4

 

PROVIDES A PROVEN UNIT

=

  UL2200 TESTED 

4

 

ENSURES A QUALITY PRODUCT

=

  RHINOCOAT PAINT SYSTEM 

4

 

IMPROVES RESISTANCE TO ELEMENTS

=

  WIDE RANGE OF ENCLOSURES AND TANKS 

4

 

PROVIDES A SINGLE SOURCE SOLUTION

Engine

=

  EPA COMPLIANT 

4

 

MEETS EPA STANDARDS

=

  INDUSTRIAL TESTED, GENERAC APPROVED 

4

 

ENSURES INDUSTRIAL STANDARDS

=

  POWER-MATCHED OUTPUT 

4

 

ENGINEERED FOR PERFORMANCE

=

  INDUSTRIAL GRADE 

4

 

IMPROVES LONGEVITY AND RELIABILITY

Alternator

=

  TWO-THIRDS PITCH 

4

 

ELIMINATES HARMFUL 3RD HARMONIC

=

  LAYER WOUND ROTOR & STATOR 

4

 

IMPROVES COOLING

=

  CLASS H MATERIALS 

4

 

HEAT TOLERANT DESIGN

=

  DIGITAL 3-PHASE VOLTAGE CONTROL 

4

 

FAST AND ACCURATE RESPONSE

Controls

=

  ENCAPSULATED BOARD W/ SEALED HARNESS 

4

 

EASY, AFFORDABLE REPLACEMENT

=

  4-20mA VOLTAGE-TO-CURRENT SENSORS 

4

 

NOISE RESISTANT 24/7 MONITORING

=

  SURFACE-MOUNT TECHNOLOGY 

4

 

PROVIDES VIBRATION RESISTANCE

=

  ADVANCED DIAGNOSTICS & COMMUNICATIONS 

4

 

HARDENED RELIABILITY

SD600

Содержание SD600

Страница 1: ... COMPLIANT 4 MEETS EPA STANDARDS INDUSTRIAL TESTED GENERAC APPROVED 4 ENSURES INDUSTRIAL STANDARDS POWER MATCHED OUTPUT 4 ENGINEERED FOR PERFORMANCE INDUSTRIAL GRADE 4 IMPROVES LONGEVITY AND RELIABILITY Alternator TWO THIRDS PITCH 4 ELIMINATES HARMFUL 3RD HARMONIC LAYER WOUND ROTOR STATOR 4 IMPROVES COOLING CLASS H MATERIALS 4 HEAT TOLERANT DESIGN DIGITAL 3 PHASE VOLTAGE CONTROL 4 FAST AND ACCURAT...

Страница 2: ...pe Full Flow Cartridge System Voltage 24VDC Crankcase Capacity L Gal 60 15 8 Battery Charging Alternator 70 Amps at 24V Battery Size at 0ºC 1155 CCA Battery Group 8D Battery Voltage 2 12VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model WEG Voltage Regulator Type Digital Poles 4 Number of Sensed Phases All Field Type Revolving Regulation Accuracy Steady State 1 Insulation Class ...

Страница 3: ...3 571 857 1143 1429 1714 2000 Upsize 2 Upsize 2 Fuel Consumption Rates STANDBY Fuel Pump Lift m ft Percent Load gph lph 3 7 12 25 18 4 69 7 50 28 2 88 7 75 35 6 134 8 100 41 4 156 7 Refer to Emissions Data Sheet for maximum fuel flow for EPA and SCAQMD permitting purposes STANDBY Coolant Flow per Minute gpm lpm 114 1 432 Heat Rejection to Coolant BTU hr 1 589 760 Inlet Air cfm m3 min 30 088 852 Ma...

Страница 4: ...r Opt Remote Relay Panel 8 or 16 Opt 7 Day Programmable Exerciser Std Special Applications Programmable PLC Std RS 232 Std RS 485 Std All Phase Sensing DVR Std Full System Status Std Utility Monitoring Req H Transfer Switch Std 2 Wire Start Compatible Std Power Output kW Std Power Factor Std Reactive Power Std All phase AC Voltage Std All phase Currents Std Oil Pressure Std Coolant Temperature Std...

Страница 5: ... TANK 8 334 24 1001 24 1001 48 2002 LEVEL 1 SOUND ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 8 334 24 1001 24 1001 48 2002 LEVEL 2 SOUND ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 8 334 24 1001 24 1001 48 2002 5 of 4 SD600 enclosure and tank configurations Generac Power Systems Inc S45 W29290 HWY 59 Waukesha WI 53189 generac com 2012 Generac Power Systems Inc All rights reserve...

Отзывы: