Commissioning
30
Installation and Owner’s Manual for Generac PWRCell Inverter
Connect PWRcell Inverter to AC
Power
IMPORTANT:
If multiple PWRcell Inverters are installed,
refer to
Commissioning Multiple Inverter Systems
place of this commissioning step. Do not turn on AC
power to more than one inverter at a time.
Turn ON main AC backfeed to power-up the inverter.
See
. On power-up, the home screen will
appear on the control panel LCD with the system mode
listed at the top of the home screen.
Figure 6-2. Inverter Power-Up
NOTE:
If grid power is temporarily not available to com
-
mission the PWRcell system and the system includes a
PWRcell Battery, performing what is called a “Blackstart”
can be used to start the system from the battery. See the
Generac PWRcell Battery Installation and Owner's
Manual
for instructions.
NOTE:
Generac does not currently support autono
-
mous, off grid installations with PWRcell equipment.
Select Inverter System Mode
NOTE:
See
for more informa
-
tion.
NOTE:
For systems with a PWRcell Battery, select a
backup system mode. Do not select Grid Tie mode.
To select a system mode:
1.
See
. While viewing the home screen
press the center button.
2.
See
. A list of system modes will be dis
-
played with the current mode marked with an aster
-
isk.
NOTE:
The list of system modes may not include all
those shown in
Figure 6-3. Selecting System Modes (1 of 3)
3.
See
. Use the up and down arrows to
highlight the desired mode and press the center
button to select.
Figure 6-4. Selecting System Modes (2 of 3)
4.
See
. Arrow right and press the center
button to select Confirm.
Figure 6-5. Selecting System Modes (3 of 3)
5.
. Verify the mode listed at the top of
the home screen is the desired mode.
Figure 6-6. Selecting System Modes (4 of 4)
Grid Tie
0.17kW
0V
DC
244V
AC
N/A
N/A
013105
Safety Shutdown
System Mode
Menu
Self Supply
Clean Backup
< EXIT SCROLL > NEXT • SELECT
Grid Tie *
009966
Safety Shutdown
System Mode
Menu
Clean Backup
< EXIT SCROLL > NEXT • SELECT
Grid Tie *
Self Supply
009967
SA
System Mode
Menu
GRd. Settings
SElibrate CTs
CLEPn: 00010003XXXX
< EXIT SCROLL > NEXT • SELECT
Self Supply
Cancel
Confirm