Generac Power Systems PowerDial RS8000E Скачать руководство пользователя страница 8

6

Owner’s Manual for Portable Generator

Know Your Generator

Replacement  owner’s  manuals  are  available

at 

www.generac.com

.

Emissions

The  United  States  Environmental  Protection

Agency  (US  EPA)  (and  California  Air

Resources Board (CARB), for engines/equip-

ment certified to California standards) requires

that  this  engine/equipment  complies  with

exhaust  and  evaporative  emissions  stan-

dards. Locate the emissions compliance decal

on  the  engine  to  determine  applicable  stan-

dards.  For  emissions  warranty  information,

please reference the included emissions war-

ranty. It is important to follow the maintenance

specifications in the manual to ensure that the

engine complies with the applicable emissions

standards for the duration of the product’s life.

Hour Meter

The Hour Meter tracks hours of operation for

scheduled maintenance. See 

Figure 2-4

.

• The  CHG  OIL display  will  illuminate  every

100 hours. The message will flash one hour

before  and  one  hour  after  each  100  hour

interval,  providing  a  two  hour  window  to

perform service.

• The  SVC  display  will  illuminate  every  100

hours.  The  message  will  flash  one  hour

before  and  one  hour  after  each  200  hour

interval providing a two hour window to per-

form service.

When  the  hour  meter  is  in  flash  alert  mode,

the  maintenance  message  will  alternate  with

elapsed  time  in  hours  and  tenths. The  hours

will  flash  four  times,  then  alternate  with  the

maintenance  message  four  times  until  the

meter automatically resets.
• 100 hours - CHG OIL — Oil Change Inter-

val (Every 100 hrs)

• 200  hours  -  SVC  —  Service  Air  Filter

(Every 200 hrs)

(000100a)

WARNING

Consult Manual. Read and understand manual
completely before using product. Failure to 
completely understand manual and product
could result in death or serious injury.

Product Specifications

Generator Specifications

Rated Power @1.0 Power Factor

8.0 kW**

Surge Power

10.0 KVA

Rated AC Voltage

120/240

Rated AC Load

  

 Current @ 240V**

   

Current @ 120V**

33.3

66.6

Rated Frequency

60 Hz @ 3600 RPM

Phase

Single Phase

Weight (dry)

   Pounds (lb)

   Kilograms (kg)

213.8

97

** Operating Temperature Range: -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F). When operated

above 25 deg. C (77 deg. F) there may be a decrease in power.

** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambi-

ent temperature, altitude, engine condition, etc. Maximum power decreases about 3.5% for each 

1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° 

F) ambient temperature.

Engine Specifications

Displacement

420cc

Spark Plug Part No.

0J00620106

Spark Plug Gap

0.028-0.031 inch or (0.70-0.80 mm)

Gasoline Capacity

30 L (8 gal)

Oil Type

See Chart in 

Add Engine Oil

Oil Capacity

1.0 L (1.06 qt.)

Run Time at 50% Load

10.5 Hours

* Go to 

www.generac.com

 or contact an IASD for replacement parts.

Содержание PowerDial RS8000E

Страница 1: ...RCHASED ______________ Register your Generac product at register generac com 1 888 922 8482 SAVE THIS MANUAL FOR FUTURE REFERENCE 000478 000209b WARNING Loss of life This product is not intended to be...

Страница 2: ...and Use Questions 11 Before Starting Engine 11 Prepare Generator for Use 11 Grounding the Generator When Used as a Portable 11 Know Generator Limits 12 Transporting Tipping of the Unit 12 Starting Pu...

Страница 3: ...d does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instruc...

Страница 4: ...us injury WARNING 000250 WARNING Equipment and property damage Do not operate unit on uneven surfaces or areas of excessive moisture dirt dust or corrosive vapors Doing so could result in death seriou...

Страница 5: ...ric motors and generators for installation and use in accordance with the Rules of the Cana dian Electrical Code 7 ANSI PGMA G300 Safety and Perfor mance of Portable Generators Portable Generator Manu...

Страница 6: ...4 Owner s Manual for Portable Generator 0H8251B 0H4635C 5 FEET 1 5m MINIMUM FROM OBJECTS CARBON MONOXIDE CO READ MANUAL...

Страница 7: ...17 18 7 13 9 11 6 12 19 10 1 120 240 Volt AC 30 Amp Locking Receptacle NEMA L14 30R 2 Circuit Breakers AC 3 Hour Meter 4 Battery Charger Input 5 120 Volt AC 20 Amp GFCI Duplex Receptacle NEMA 5 20R 6...

Страница 8: ...rnate with elapsed time in hours and tenths The hours will flash four times then alternate with the maintenance message four times until the meter automatically resets 100 hours CHG OIL Oil Change Int...

Страница 9: ...t a suitable 4 wire grounded cord set to plug and desired load The cord set should be rated 250 Volts AC at 30 Amps or greater See Figure 2 6 Use this receptacle to operate 120 Volt AC 60 Hz single ph...

Страница 10: ...ad bolts L through rubber bumper D then through frame foot C 2 Slide hex head bolts K through holes in frame rail 3 Slide frame foot C onto hex head bolts K Install locking flange nuts J Install handl...

Страница 11: ...n fresh unleaded gasoline Minimum rating of 87 octane 87 AKI 91 RON Up to 10 ethanol gasohol is acceptable where available non ethanol premium fuel is recommended DO NOT use E85 DO NOT use a gas oil m...

Страница 12: ...from forming in fuel system parts such as the carburetor fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and fo...

Страница 13: ...m It is recommended to use a manual transfer switch when connecting directly to a building electrical system Connecting a portable gen erator to a building electrical system must be made in strict com...

Страница 14: ...e for wattage requirements Wattage Reference Guide Transporting Tipping of the Unit Do not operate store or transport the unit at an angle greater than 15 degrees Device Running Watts Air Conditioner...

Страница 15: ...arts release switch 3 See Figure 3 3 When engine starts rotate PowerDial to RUN Choke operation is reduced as PowerDial is rotated towards RUN If engine falters rotate PowerDial counterclockwise to ST...

Страница 16: ...n use for pro longed periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY Use battery ch...

Страница 17: ...and unobstructed NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems If water enters generator through cooling air slots some water will be retained...

Страница 18: ...nd oil drain plug 4 Remove oil fill cap 5 Remove oil drain plug and drain oil com pletely into a suitable container 6 Install oil drain plug and tighten securely 7 Slowly pour oil into oil fill openin...

Страница 19: ...iolation of California Public Resource Code Section 4442 to use or oper ate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arre...

Страница 20: ...stabilizer is added to fuel system pre pare and run engine for long term storage Run engine for 10 15 minutes to circulate sta bilizer throughout fuel system Adequately prepared fuel can be stored up...

Страница 21: ...Dirty air filter 3 Out of fuel 4 Stale fuel 5 Spark plug wire not connected to spark plug 6 Bad spark plug 7 Water in fuel 8 Overchoking 9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve...

Страница 22: ...20 Owner s Manual for Portable Generator Notes...

Страница 23: ...Owner s Manual for Portable Generator 21...

Страница 24: ...rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W2929...

Отзывы: