Generac Power Systems PowerDial RS8000E Скачать руководство пользователя страница 13

Owner’s Manual for Portable Generator

11

Section 3 Operation

Operation and Use Questions

Call Generac customer service at 1-888-GEN-

ERAC  (1-888-436-3722)  with  questions  or

concerns  about  equipment  operation  and

maintenance.

Before Starting Engine

1. Verify engine oil level is correct.
2. Verify fuel level is correct.
3. Verify unit is secure on level ground, with

proper clearance and is in a well ventilated

area.

Prepare Generator for Use

Grounding the Generator When 

Used as a Portable

The generator is equipped with an equipment

ground  connecting  the  generator  frame  and

the ground terminals on the AC output recep-

tacles  (see  NEC  250.34  (A).  This  allows  the

generator  to  be  used  as  a  portable  without

grounding the frame of the generator as spec-

ified in NEC 250.34. See 

Figure 3-1

.

• Neutral Bonded to Frame.

Figure 3-1. Grounding the Generator

Special Requirements

Review  all  Federal  or  State  Occupational

Safety and Health Administration (OSHA) reg-

ulations, local codes, or ordinances that apply

to the intended use of the generator.
Consult  a  qualified  electrician,  electrical

inspector, or the local agency having jurisdic-

tion:
• In some areas, generators are required to

be registered with local utility companies.

• If  the  generator  is  used  at  a  construction

site,  there  may  be  additional  regulations

which must be observed.

Connecting the Generator to a 
Building Electrical System

It  is  recommended  to  use  a  manual  transfer

switch  when  connecting  directly  to  a  building

electrical system. Connecting a portable gen-

erator to a building electrical system must be

made in strict compliance with all national and

local  electrical  codes  and  laws,  and  be  com-

pleted by a qualified electrician.

Asphyxiation. Running engines produce 
carbon monoxide, a colorless, odorless, 
poisonous gas. Carbon monoxide, if not 
avoided, will result in death or serious injury.

(000103)

DANGER

(000178a)

Asphyxiation. Always use a battery operated carbon 
monoxide alarm indoors and installed according to 
the manufacturer’s instructions. Failure to do so 
could result in death or serious injury.

WARNING

(000179b)

DANGER

Asphyxiation. The exhaust system must be properly 
maintained. Do not alter or modify the exhaust system 
as to render it unsafe or make it noncompliant with 
local codes and/or standards. Failure to do so will 
result in death or serious injury.

WARNING

(000118a)

Risk of fire. Do not use generator without 
spark arrestor installed. Failure to do so 
could result in death or serious injury.

 

(000110)

WARNING

Risk of Fire. Hot surfaces could ignite 
combustibles, resulting in fire. Fire could 
result in death or serious injury.

(000108)

WARNING

Hot Surfaces. When operating machine, do not 
touch hot surfaces. Keep machine away from 
combustibles during use. Hot surfaces could 
result in severe burns or fire.

(000136)

CAUTION

Equipment and property damage. Disconnect electrical 
loads prior to starting or stopping unit. Failure to do so 
could result in equipment and property damage.

000227

Содержание PowerDial RS8000E

Страница 1: ...RCHASED ______________ Register your Generac product at register generac com 1 888 922 8482 SAVE THIS MANUAL FOR FUTURE REFERENCE 000478 000209b WARNING Loss of life This product is not intended to be...

Страница 2: ...and Use Questions 11 Before Starting Engine 11 Prepare Generator for Use 11 Grounding the Generator When Used as a Portable 11 Know Generator Limits 12 Transporting Tipping of the Unit 12 Starting Pu...

Страница 3: ...d does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instruc...

Страница 4: ...us injury WARNING 000250 WARNING Equipment and property damage Do not operate unit on uneven surfaces or areas of excessive moisture dirt dust or corrosive vapors Doing so could result in death seriou...

Страница 5: ...ric motors and generators for installation and use in accordance with the Rules of the Cana dian Electrical Code 7 ANSI PGMA G300 Safety and Perfor mance of Portable Generators Portable Generator Manu...

Страница 6: ...4 Owner s Manual for Portable Generator 0H8251B 0H4635C 5 FEET 1 5m MINIMUM FROM OBJECTS CARBON MONOXIDE CO READ MANUAL...

Страница 7: ...17 18 7 13 9 11 6 12 19 10 1 120 240 Volt AC 30 Amp Locking Receptacle NEMA L14 30R 2 Circuit Breakers AC 3 Hour Meter 4 Battery Charger Input 5 120 Volt AC 20 Amp GFCI Duplex Receptacle NEMA 5 20R 6...

Страница 8: ...rnate with elapsed time in hours and tenths The hours will flash four times then alternate with the maintenance message four times until the meter automatically resets 100 hours CHG OIL Oil Change Int...

Страница 9: ...t a suitable 4 wire grounded cord set to plug and desired load The cord set should be rated 250 Volts AC at 30 Amps or greater See Figure 2 6 Use this receptacle to operate 120 Volt AC 60 Hz single ph...

Страница 10: ...ad bolts L through rubber bumper D then through frame foot C 2 Slide hex head bolts K through holes in frame rail 3 Slide frame foot C onto hex head bolts K Install locking flange nuts J Install handl...

Страница 11: ...n fresh unleaded gasoline Minimum rating of 87 octane 87 AKI 91 RON Up to 10 ethanol gasohol is acceptable where available non ethanol premium fuel is recommended DO NOT use E85 DO NOT use a gas oil m...

Страница 12: ...from forming in fuel system parts such as the carburetor fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and fo...

Страница 13: ...m It is recommended to use a manual transfer switch when connecting directly to a building electrical system Connecting a portable gen erator to a building electrical system must be made in strict com...

Страница 14: ...e for wattage requirements Wattage Reference Guide Transporting Tipping of the Unit Do not operate store or transport the unit at an angle greater than 15 degrees Device Running Watts Air Conditioner...

Страница 15: ...arts release switch 3 See Figure 3 3 When engine starts rotate PowerDial to RUN Choke operation is reduced as PowerDial is rotated towards RUN If engine falters rotate PowerDial counterclockwise to ST...

Страница 16: ...n use for pro longed periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY Use battery ch...

Страница 17: ...and unobstructed NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems If water enters generator through cooling air slots some water will be retained...

Страница 18: ...nd oil drain plug 4 Remove oil fill cap 5 Remove oil drain plug and drain oil com pletely into a suitable container 6 Install oil drain plug and tighten securely 7 Slowly pour oil into oil fill openin...

Страница 19: ...iolation of California Public Resource Code Section 4442 to use or oper ate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arre...

Страница 20: ...stabilizer is added to fuel system pre pare and run engine for long term storage Run engine for 10 15 minutes to circulate sta bilizer throughout fuel system Adequately prepared fuel can be stored up...

Страница 21: ...Dirty air filter 3 Out of fuel 4 Stale fuel 5 Spark plug wire not connected to spark plug 6 Bad spark plug 7 Water in fuel 8 Overchoking 9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve...

Страница 22: ...20 Owner s Manual for Portable Generator Notes...

Страница 23: ...Owner s Manual for Portable Generator 21...

Страница 24: ...rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W2929...

Отзывы: