Generac Power Systems PowerDial RS8000E Скачать руководство пользователя страница 17

Owner’s Manual for Portable Generator

15

Section 4 Maintenance and Troubleshooting

Maintenance

Regular  maintenance  will  improve  perfor-

mance  and  extend  engine/equipment  life.

Generac  Power  Systems,  Inc.  recommends

that all maintenance work be performed by an

Independent  Authorized  Service  Dealer

(IASD).  Regular  maintenance,  replacement,

or repair of the emissions control devices and

systems may be performed by any repair shop

or  person  of  the  owner’s  choosing. To  obtain

emissions  control  warranty  service  free  of

charge,  the  work  must  be  performed  by  an

IASD. See the emissions warranty.

NOTE: 

Call  1-888-GENERAC  (1-888-436-

3722)  with  questions  about  component

replacement.

Maintenance Schedule

Follow  maintenance  schedule  intervals,

whichever occurs first according to use.

NOTE: 

Adverse  conditions  will  require  more

frequent service.

NOTE: 

Go  to  Generac.com  or  contact  an

IASD for replacement parts.

NOTE: 

All  required  service  and  adjustments

should be each season as detailed in the fol-

lowing chart.

Preventive Maintenance

Dirt  or  debris  can  cause  improper  operation

and  equipment  damage.  Clean  generator

daily  or  before  each  use.  Keep  area  around

and  behind  muffler  free  from  combustible

debris.  Inspect  all  cooling  air  openings  on

generator.

• Use a damp cloth to wipe exterior surfaces

clean.

• Use a soft bristle brush to loosen caked on

dirt, oil, etc.

• Use  a  vacuum  to  pick  up  loose  dirt  and

debris.

• Low  pressure  air  (not  to  exceed  25  psi)

may  be  used  to  blow  away  dirt.  Inspect

cooling air slots and openings on generator.

These  openings  must  be  kept  clean  and

unobstructed.

NOTE: 

DO NOT use a garden hose to clean

generator. Water can enter engine fuel system

and cause problems. If water enters generator

through  cooling  air  slots,  some  water  will  be

retained in voids and crevices of rotor and sta-

tor  winding  insulation.  Water  and  dirt  buildup

on  generator  internal  windings  will  decrease

insulation resistance of windings.

Engine Maintenance

Engine Oil Recommendations

To  maintain  the  product  warranty,  the  engine

oil should be serviced in accordance with the

recommendations  of  this  manual.  For  your

convenience, maintenance kits designed and

intended for use on this product are available

from the manufacturer that include engine oil,

oil  filter,  air  filter,  spark  plug(s),  a  shop  towel

and  funnel. These  kits  can  be  obtained  from

an  Independent  Authorized  Service  Dealer

(IASD).

At Each Use

Check engine oil level

Every 100 Hours or Every Season*

Change oil ǂ
Inspect/clean spark arrestor

Every Season

Replace Spark Plug
Check Valve Clearance***

Every 200 Hours or Every Season

Inspect/clean air cleaner filter**
ǂ Change oil after first 30 hours of operation,

then every season.

*  Change  oil  every  month  when  operating

under heavy load or in high temperatures.

** Clean more often under dirty or dusty oper-

ating  conditions.  Replace  air  filter  parts  if

they cannot be adequately cleaned.

*** Check valve clearance and adjust if neces-

sary  after  first  50  hours  of  operation  and

every 300 hours thereafter.

(000142a)

Personal injury. Do not insert any object through the 
air cooling slots. Generator can start at any time and 
could result in death, serious injury, and unit damage.

WARNING

(000141)

WARNING

Accidental start-up. Disconnect spark plug wires when 
working on unit. Failure to do so could result in death 
or serious injury.

Содержание PowerDial RS8000E

Страница 1: ...RCHASED ______________ Register your Generac product at register generac com 1 888 922 8482 SAVE THIS MANUAL FOR FUTURE REFERENCE 000478 000209b WARNING Loss of life This product is not intended to be...

Страница 2: ...and Use Questions 11 Before Starting Engine 11 Prepare Generator for Use 11 Grounding the Generator When Used as a Portable 11 Know Generator Limits 12 Transporting Tipping of the Unit 12 Starting Pu...

Страница 3: ...d does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instruc...

Страница 4: ...us injury WARNING 000250 WARNING Equipment and property damage Do not operate unit on uneven surfaces or areas of excessive moisture dirt dust or corrosive vapors Doing so could result in death seriou...

Страница 5: ...ric motors and generators for installation and use in accordance with the Rules of the Cana dian Electrical Code 7 ANSI PGMA G300 Safety and Perfor mance of Portable Generators Portable Generator Manu...

Страница 6: ...4 Owner s Manual for Portable Generator 0H8251B 0H4635C 5 FEET 1 5m MINIMUM FROM OBJECTS CARBON MONOXIDE CO READ MANUAL...

Страница 7: ...17 18 7 13 9 11 6 12 19 10 1 120 240 Volt AC 30 Amp Locking Receptacle NEMA L14 30R 2 Circuit Breakers AC 3 Hour Meter 4 Battery Charger Input 5 120 Volt AC 20 Amp GFCI Duplex Receptacle NEMA 5 20R 6...

Страница 8: ...rnate with elapsed time in hours and tenths The hours will flash four times then alternate with the maintenance message four times until the meter automatically resets 100 hours CHG OIL Oil Change Int...

Страница 9: ...t a suitable 4 wire grounded cord set to plug and desired load The cord set should be rated 250 Volts AC at 30 Amps or greater See Figure 2 6 Use this receptacle to operate 120 Volt AC 60 Hz single ph...

Страница 10: ...ad bolts L through rubber bumper D then through frame foot C 2 Slide hex head bolts K through holes in frame rail 3 Slide frame foot C onto hex head bolts K Install locking flange nuts J Install handl...

Страница 11: ...n fresh unleaded gasoline Minimum rating of 87 octane 87 AKI 91 RON Up to 10 ethanol gasohol is acceptable where available non ethanol premium fuel is recommended DO NOT use E85 DO NOT use a gas oil m...

Страница 12: ...from forming in fuel system parts such as the carburetor fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and fo...

Страница 13: ...m It is recommended to use a manual transfer switch when connecting directly to a building electrical system Connecting a portable gen erator to a building electrical system must be made in strict com...

Страница 14: ...e for wattage requirements Wattage Reference Guide Transporting Tipping of the Unit Do not operate store or transport the unit at an angle greater than 15 degrees Device Running Watts Air Conditioner...

Страница 15: ...arts release switch 3 See Figure 3 3 When engine starts rotate PowerDial to RUN Choke operation is reduced as PowerDial is rotated towards RUN If engine falters rotate PowerDial counterclockwise to ST...

Страница 16: ...n use for pro longed periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY Use battery ch...

Страница 17: ...and unobstructed NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems If water enters generator through cooling air slots some water will be retained...

Страница 18: ...nd oil drain plug 4 Remove oil fill cap 5 Remove oil drain plug and drain oil com pletely into a suitable container 6 Install oil drain plug and tighten securely 7 Slowly pour oil into oil fill openin...

Страница 19: ...iolation of California Public Resource Code Section 4442 to use or oper ate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arre...

Страница 20: ...stabilizer is added to fuel system pre pare and run engine for long term storage Run engine for 10 15 minutes to circulate sta bilizer throughout fuel system Adequately prepared fuel can be stored up...

Страница 21: ...Dirty air filter 3 Out of fuel 4 Stale fuel 5 Spark plug wire not connected to spark plug 6 Bad spark plug 7 Water in fuel 8 Overchoking 9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve...

Страница 22: ...20 Owner s Manual for Portable Generator Notes...

Страница 23: ...Owner s Manual for Portable Generator 21...

Страница 24: ...rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W2929...

Отзывы: