![Generac Power Systems PowerDial RS8000E Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/generac-power-systems/powerdial-rs8000e/powerdial-rs8000e_owners-manual_2209626016.webp)
14
Owner’s Manual for Portable Generator
Restarting Hot Engines
NOTE:
The generator is off and the PowerDial
is turned to the STOP position. Turning the
PowerDial counterclockwise, past the RUN
position, turns on the fuel and permits use of
electric starter. The PowerDial MUST be
turned from the STOP position to just past the
RUN position to restart the fuel flow. The
choke is not required if the engine is hot.
1. See
. Turn PowerDial counter-
clockwise, from STOP until just past RUN.
This will reopen the fuel valve and permit
electric start or recoil starting.
2. Press PowerDial button in this position to
electric start (8.0 kW only) or firmly grasp
the recoil handle and pull slowly until
increased resistance is felt. Pull rapidly up
and away.
3. Turn PowerDial clockwise to RUN.
Low Oil Level Shutdown System
The engine is equipped with a low oil level
sensor to shut down the engine automatically
when the oil level drops below a specified
level. The engine will not run until the oil has
been filled to the proper level.
IMPORTANT NOTE: Verify proper engine oil
and fuel levels before use.
Charging the Battery
NOTE:
The battery shipped with the generator
has been fully charged. A battery may lose
some of its charge when not in use for pro-
longed periods of time. If the battery is unable
to crank the engine, plug in the 12V charger
included in the accessory box. RUNNING
THE GENERATOR DOES NOT CHARGE
THE BATTERY.
Use battery charger plug to keep the battery
charged and ready for use. Battery charging
should be done in a dry location.
1. Plug charger into Battery Charger Input
jack, located on the control panel. See
. Plug wall receptacle end of battery
charger into 120 Volt AC wall outlet.
2. Unplug battery charger from wall outlet
and control panel jack when generator is
to be in use.
Figure 3-5. Battery Charger Input Jack
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
(000137a)
WARNING
Explosion. Batteries emit explosive gases while charging.
Keep fire and spark away. Wear protective gear when
working with batteries. Failure to do so could result in
death or serious injury.
(000138a)
WARNING
Risk of burns. Batteries contain sulfuric acid and
can cause severe chemical burns. Wear protective
gear when working with batteries. Failure to do
so could result in death or serious injury.
%$77(5<
&+$5*(5
,1387
000423
WARNING
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death or serious injury.