Restarting Hot Engines

NOTE: 

The generator is off and the PowerDial

is  turned  to  the  STOP  position.  Turning  the

PowerDial  counterclockwise,  past  the  RUN

position, turns on the fuel and permits use of

electric  starter.  The  PowerDial  MUST  be

turned from the STOP position to just past the

RUN  position  to  restart  the  fuel  flow.  The

choke is not required if the engine is hot.
1. See 

Figure 3-3

.  Turn  PowerDial  counter-

clockwise, from STOP until just past RUN.

This will reopen the fuel valve and permit

electric start or recoil starting.

2. Press PowerDial button in this position to

electric start (8.0 kW only) or firmly grasp

the  recoil  handle  and  pull  slowly  until

increased resistance is felt. Pull rapidly up

and away.

3. Turn PowerDial clockwise to RUN.

Low Oil Level Shutdown System

The  engine  is  equipped  with  a  low  oil  level

sensor to shut down the engine automatically

when  the  oil  level  drops  below  a  specified

level. The engine will not run until the oil has

been filled to the proper level.

IMPORTANT NOTE: Verify proper engine oil
and fuel levels before use.

Charging the Battery

NOTE: 

The battery shipped with the generator

has  been  fully  charged.  A  battery  may  lose

some  of  its  charge  when  not  in  use  for  pro-

longed periods of time. If the battery is unable

to  crank  the  engine,  plug  in  the  12V  charger

included  in  the  accessory  box.  RUNNING

THE  GENERATOR  DOES  NOT  CHARGE

THE BATTERY.
Use  battery  charger  plug  to  keep  the  battery

charged  and  ready  for  use.  Battery  charging

should be done in a dry location.

1. Plug  charger  into  Battery  Charger  Input

jack, located on the control panel. See 

Fig-

ure 3-5

Plug wall receptacle end of battery

charger into 120 Volt AC wall outlet.

2. Unplug  battery  charger  from  wall  outlet

and  control  panel  jack  when  generator  is

to be in use.

Figure 3-5.  Battery Charger Input Jack

(000136)

CAUTION

Equipment and property damage. Disconnect electrical 
loads prior to starting or stopping unit. Failure to do so 
could result in equipment and property damage.

(000137a)

WARNING

Explosion. Batteries emit explosive gases while charging. 
Keep fire and spark away. Wear protective gear when 
working with batteries. Failure to do so could result in 
death or serious injury. 

 

(000138a)

WARNING

Risk of burns. Batteries contain sulfuric acid and 
can cause severe chemical burns.  Wear protective 
gear when working with batteries. Failure to do 
so could result in death or serious injury.

%$77(5<

&+$5*(5

,1387

000423

WARNING

Environmental Hazard. Always recycle batteries at an 
official recycling center in accordance with all local 
laws and regulations. Failure to do so could result in
environmental damage, death or serious injury.

(000228)

Содержание PowerDial RS8000E

Страница 1: ...RCHASED ______________ Register your Generac product at register generac com 1 888 922 8482 SAVE THIS MANUAL FOR FUTURE REFERENCE 000478 000209b WARNING Loss of life This product is not intended to be...

Страница 2: ...and Use Questions 11 Before Starting Engine 11 Prepare Generator for Use 11 Grounding the Generator When Used as a Portable 11 Know Generator Limits 12 Transporting Tipping of the Unit 12 Starting Pu...

Страница 3: ...d does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instruc...

Страница 4: ...us injury WARNING 000250 WARNING Equipment and property damage Do not operate unit on uneven surfaces or areas of excessive moisture dirt dust or corrosive vapors Doing so could result in death seriou...

Страница 5: ...ric motors and generators for installation and use in accordance with the Rules of the Cana dian Electrical Code 7 ANSI PGMA G300 Safety and Perfor mance of Portable Generators Portable Generator Manu...

Страница 6: ...4 Owner s Manual for Portable Generator 0H8251B 0H4635C 5 FEET 1 5m MINIMUM FROM OBJECTS CARBON MONOXIDE CO READ MANUAL...

Страница 7: ...17 18 7 13 9 11 6 12 19 10 1 120 240 Volt AC 30 Amp Locking Receptacle NEMA L14 30R 2 Circuit Breakers AC 3 Hour Meter 4 Battery Charger Input 5 120 Volt AC 20 Amp GFCI Duplex Receptacle NEMA 5 20R 6...

Страница 8: ...rnate with elapsed time in hours and tenths The hours will flash four times then alternate with the maintenance message four times until the meter automatically resets 100 hours CHG OIL Oil Change Int...

Страница 9: ...t a suitable 4 wire grounded cord set to plug and desired load The cord set should be rated 250 Volts AC at 30 Amps or greater See Figure 2 6 Use this receptacle to operate 120 Volt AC 60 Hz single ph...

Страница 10: ...ad bolts L through rubber bumper D then through frame foot C 2 Slide hex head bolts K through holes in frame rail 3 Slide frame foot C onto hex head bolts K Install locking flange nuts J Install handl...

Страница 11: ...n fresh unleaded gasoline Minimum rating of 87 octane 87 AKI 91 RON Up to 10 ethanol gasohol is acceptable where available non ethanol premium fuel is recommended DO NOT use E85 DO NOT use a gas oil m...

Страница 12: ...from forming in fuel system parts such as the carburetor fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and fo...

Страница 13: ...m It is recommended to use a manual transfer switch when connecting directly to a building electrical system Connecting a portable gen erator to a building electrical system must be made in strict com...

Страница 14: ...e for wattage requirements Wattage Reference Guide Transporting Tipping of the Unit Do not operate store or transport the unit at an angle greater than 15 degrees Device Running Watts Air Conditioner...

Страница 15: ...arts release switch 3 See Figure 3 3 When engine starts rotate PowerDial to RUN Choke operation is reduced as PowerDial is rotated towards RUN If engine falters rotate PowerDial counterclockwise to ST...

Страница 16: ...n use for pro longed periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY Use battery ch...

Страница 17: ...and unobstructed NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems If water enters generator through cooling air slots some water will be retained...

Страница 18: ...nd oil drain plug 4 Remove oil fill cap 5 Remove oil drain plug and drain oil com pletely into a suitable container 6 Install oil drain plug and tighten securely 7 Slowly pour oil into oil fill openin...

Страница 19: ...iolation of California Public Resource Code Section 4442 to use or oper ate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arre...

Страница 20: ...stabilizer is added to fuel system pre pare and run engine for long term storage Run engine for 10 15 minutes to circulate sta bilizer throughout fuel system Adequately prepared fuel can be stored up...

Страница 21: ...Dirty air filter 3 Out of fuel 4 Stale fuel 5 Spark plug wire not connected to spark plug 6 Bad spark plug 7 Water in fuel 8 Overchoking 9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve...

Страница 22: ...20 Owner s Manual for Portable Generator Notes...

Страница 23: ...Owner s Manual for Portable Generator 21...

Страница 24: ...rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W2929...

Отзывы: