![Generac Power Systems MAGNUM MLT6SKDS Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/generac-power-systems/magnum-mlt6skds/magnum-mlt6skds_owners-manual_2208958023.webp)
General Information
Owner’s Manual for MLT6SMDS - MLT6SKDS Light Tower
19
Power Zone–DLA (If Equipped)
The Power Zone–DLA is an AUTO start controller that
monitors the unit and indicates operational status and
fault conditions. The controller can be programmed to
automatically start or stop based on time schedule, fault
condition, or load demand.
The controller constantly monitors vital generator and
engine functions for a number of preprogrammed alarm
and fault conditions. When a fault condition occurs, the
engine shuts down automatically and the LCD window
shows the fault that caused the shutdown. To resume
operation, the fault condition must be corrected.
This controller records a history of unit performance,
which may be viewed at any time and will not be lost
when the controller is powered down.
Figure 2-13. Power Zone–DLA Layout
Controller Features and Functions
(A) The Liquid Crystal Display (LCD) Window
Displays the various operating screens. By viewing these
screens, the operator can monitor both the engine and
generator status while the unit is running.
(B) Select LED
Illuminates when the unit is running in AUTO mode.
(C) Start LED
Illuminates when the unit is running in MANUAL mode.
(D) Start Button
Starts the engine if there are no shutdown errors and the
engine is in “ready to start” status.
(E) Stop Button
Shuts down the unit and puts the controller into STOP
mode, whether in MANUAL mode or AUTO mode.
NOTE:
To prevent damage to the generator and con-
nected equipment, remove all loads from the generator
by opening all circuit breakers (turn OFF [O]) before
pressing the STOP button.
(F) Stop LED
Illuminates when the unit is in STOP mode and flashes
when an Electrical Trip and Shutdown Fault has
occurred.
(G) Select Button
Confirms entries chosen in the various edit menus and
screens. Navigates between AUTO and MANUAL mode.
(H) Menu Navigation
Up/down arrows (↑, ↓) used to navigate through the
various operator screens. They are also used to raise
and lower the mast on units equipped with an electric
winch.
Select
A
B
C
D
F
G
H
E
002353
Содержание MAGNUM MLT6SKDS
Страница 46: ...Maintenance 42 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower This page intentionally left blank...
Страница 52: ...Wiring Diagrams 48 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower AC Wiring Diagram MLT6SKDS With Power Zone...
Страница 65: ...Service Log Owner s Manual for MLT6SMDS MLT6SKDS Light Tower 61 This page intentionally left blank...
Страница 66: ...Service Log 62 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower This page intentionally left blank...
Страница 67: ......