Maintenance
40
Owner’s Manual for MLT4060MVD Light Tower
•
Check the oil level daily. Refer to the engine
operator’s manual for the appropriate oil
specification. Make sure that the oil is correct for
special operating conditions such as a change in
season or climate.
•
DO NOT
start the unit if the engine oil level is
below the add mark on the dipstick.
• Normal operating level is in the cross-hatch
pattern between the full and add markings on
the dipstick.
• Add oil only if the oil level is below the add mark
on the bottom of the cross-hatch pattern on the
dipstick.
DO NOT OVERFILL
the crankcase.
•
Check the fuel level.
•
If the unit is connected to a remote start or
transfer switch, make sure the remote switch is
also off and tagged.
NOTE:
If the engine was run out of fuel or the fuel tank
was drained, it may be necessary to bleed the fuel lines.
Refer to the engine operator’s manual supplied with the
unit.
* Perform after the initial 50 hours of operation ONLY, then on the regularly scheduled interval as indicated in the table above.
† Generac Mobile Products recommends that oil change intervals on the ECOSpeed engine be extended to 750 hours after initial break-
in. The engine comes from the factory with a larger sump that holds 5.5 quarts (5.2 L) of engine oil. After the initial 50 hour break-in and
oil change, the sump, coupled with the larger oil filter (P/N 10000014392), allows the engine to operate up to 750 hours between
routine oil changes.
Hot, humid or dusty conditions can shorten engine oil service life, regardless of suggested oil change intervals. In extreme conditions,
determine oil life and change intervals through regular oil sampling and analysis.
Always follow the recommendations of the OEM engine manual that was shipped with the unit for specific operating instructions. If further technical
assistance is required, contact Generac Mobile Products Technical Service at 1-800-926-9768.
Table 4-1. Basic Maintenance Schedule
Item
Daily
750
Hours
As
Required
Perform a daily walk-around inspection; see
Check Oil Level
Check Coolant Level
Check Fuel Level
Check Tire Pressure
Check All Electrical Connections
Inspect Radiator Fins For Debris, Clean As Required
Inspect Light Tower Winch For Proper Operation
Replace Engine Oil and Oil Filter
*†
Belt And Belt Tension— Inspect, Adjust, and Replace if Necessary
*
Replace Fuel Filter
Check Battery Condition
Replace Air Cleaner Element
Lubricate Leveling Jacks
Fuel System— Bleed Air
Drain Residual Water From Fuel Filter
Содержание MAGNUM MLT4060MVD
Страница 11: ...Introduction and Safety Owner s Manual for MLT4060MVD Light Tower 7 Figure 1 1 External Decals...
Страница 14: ...Introduction and Safety 10 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Страница 28: ...General Information 24 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Страница 42: ...Operation 38 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Страница 48: ...Maintenance 44 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Страница 52: ...Electrical Drawings 48 Owner s Manual for MLT4060MVD Light Tower Components Located on Engine p 2...
Страница 53: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 49 Components Located on Engine p 3...
Страница 54: ...Electrical Drawings 50 Owner s Manual for MLT4060MVD Light Tower Components Located on Engine p 4...
Страница 55: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 51 Accessories...
Страница 56: ...Electrical Drawings 52 Owner s Manual for MLT4060MVD Light Tower Optional Accessories...
Страница 57: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 53...
Страница 58: ...Electrical Drawings 54 Owner s Manual for MLT4060MVD Light Tower...
Страница 60: ...Electrical Drawings 56 Owner s Manual for MLT4060MVD Light Tower...
Страница 62: ...Electrical Drawings 58 Owner s Manual for MLT4060MVD Light Tower Components Located in LED Box...
Страница 63: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 59 Engine Control Module Function Table...
Страница 64: ...Electrical Drawings 60 Owner s Manual for MLT4060MVD Light Tower Engine Control Module Connections...
Страница 65: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 61 AC Schematic...
Страница 66: ...Electrical Drawings 62 Owner s Manual for MLT4060MVD Light Tower Relays p 1...
Страница 67: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 63 Relays p 2...
Страница 68: ...Electrical Drawings 64 Owner s Manual for MLT4060MVD Light Tower DC Connections p 1...
Страница 69: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 65 DC Connections p 2...
Страница 70: ...Electrical Drawings 66 Owner s Manual for MLT4060MVD Light Tower...
Страница 71: ......