Generac Power Systems GEN27WN Скачать руководство пользователя страница 9

Installation

We sincerely appreciate your patronage. For this reason, we 

have made every effort to provide for a safe, streamlined 

and cost-effective installation. Because each installation is 

unique, it is impossible to know of and advise the trade of all 

conceivable procedures and methods by which installation 

might be achieved. Neither could we know of possible 

hazards and/or the results of each method or procedure. For 

these reasons,

Only current licensed electrical and plumbing 
contractors should attempt residential generator 
system installations. Installations must strictly 
comply with all applicable codes, industry 
standards and regulations.

Your residential generator is supplied with this “Operator’s 

Manual” and a separate “Installation Manual”. These are 

important documents and should be retained by the owner 

after the installation has been completed.

For the Home Owner

To help you make informed choices and communicate 

effectively with your installation contractor(s),

Read and understand 

Owner Orientation

 in 

this manual before contracting or starting your 
residential generator installation.

To arrange for proper installation, contact the store at which 

you purchased your residential generator, your dealer, a 

licensed electrician or your utility power provider.

The residential generator warranty is VOID unless 
the system is installed by licensed electrical and 
plumbing professionals.

The Emission Control System for this generator is warranted 

for standards set by the U.S. Environmental Protection 

Agency and by the California Air Resources Board (CARB).

For the Installing Dealer/Contractor

For most applications, the Installation manual contains all 

the information required to properly install and start the 

residential generator. This Operator’s Manual describes 

essential circuit selection, routine operation and owner 

maintenance procedures.
If you need more information, call 

(877) 369-9400

between 8:00 AM and 5:00 PM CT.

Owner Orientation

This section provides residential generator owners with the 

information necessary to achieve the most satisfactory and 

cost effective installation possible.
Illustrations are for typical circumstances and are meant to 

familiarize you with the installation options available with 

your system. A thorough understanding of these options will 

provide some control over the cost of your installation, as 

well as ensure your final satisfaction and security.

Federal and local codes, appearance, noise levels, fuel types, 

and distances are the factors that must be considered when 

negotiating with an installation professional. Remember 

that as the distance from the existing electrical service and 

gaseous fuel supply increases, and the number of 90 degree 

bends in the fuel supply increases; compensations in piping 

and wiring materials must be made. This is necessary to 

comply with local codes and overcome electrical voltage 

drops and gaseous fuel pressure drops.

The factors mentioned above will have a direct 
affect on the overall price of your residential 
generator installation.
NOTE

: In some areas you may need to acquire electrical 

permits for installing the residential generator, building 

permits for installing gas lines, and permits for noise 

allowances. Your installer should check your local codes 

AND obtain the permits before installing the system.

Fuel Factors

This residential generator system was factory tested and 

adjusted using either LP vapor or natural gas. For proper 

engine function, factors that are inherent to each of these 

fuels, your location and the duration of possible utility 

interruptions are important considerations in the following 

fuel guidelines:
  •  Use clean, dry fuel, free of moisture or any 

particulate material. Using fuels outside the 

following recommended values may cause 

performance problems.

  •  For engines set up to run on propane vapor (LP), 

commercial grade HD5 propane with a minimum fuel 

energy of 2500 BTUs/ft3 with maximum propylene 

content of 5% and butane and heavier gas content of 

2.5% and minimum propane content of 90%.

 WaRNING

Propane and Natural Gas are extremely 

flammable and explosive.
Fire or explosion can cause severe burns 

or death.

The residential generator is equipped with an automatic 

safety gas “fuel shut-off” valve.
DO NOT operate the equipment if the “fuel shut-off” valve 

is missing or inoperative.

Power Decrease at High altitude or High Temperature

Air density is less at high altitudes, resulting in less available 

engine power. Specifically, engine power will decrease 3.5% 

for each 1,000 feet (300 meters) above sea level and 1% for 

each 10° F (5.6°C) above 77°F (25°C). Make sure you and 

your installer consider these factors when determining total 

generator load.

9

Содержание GEN27WN

Страница 1: ...Questions Help is just a moment away Call Home Generator Helpline 877 369 9400 M F 8 5 CT Liquid Cooled Residential Generator System Operator s Manual GEN27WN GEN30WL GEN42WN GEN45WL...

Страница 2: ...id them Because Rheem does not necessarily know all the applications this equipment could be used for it is important that you read and understand these instructions thoroughly before attempting to st...

Страница 3: ...cuits 10 Delivery Inspection 11 Features and Controls 12 30 kW Residential Generator 12 45 kW Home Generator 13 System Control Panel 14 Operation 16 Automatic Operation 16 Setting Exercise Timer 17 Ma...

Страница 4: ...monoxide can cause headache fatigue dizziness vomiting confusion seizures nausea fainting or death Operate generator ONLY outdoors Install a battery operated carbon monoxide alarm near the bedrooms K...

Страница 5: ...he 15 Amp fuse BEFORE working on the equipment warning Propane and Natural Gas are extremely flammable and explosive Fire or explosion can cause severe burns or death Install the fuel supply system ac...

Страница 6: ...or can damage it and shorten its life Use generator only for intended uses If you have questions about intended use contact your authorized dealer Operate generator only on level surfaces Adequate uno...

Страница 7: ...Safety Label Locations 30kW...

Страница 8: ...Safety Label Locations 45kW...

Страница 9: ...with your system A thorough understanding of these options will provide some control over the cost of your installation as well as ensure your final satisfaction and security Federal and local codes...

Страница 10: ...to include as Essential Circuits Depending on the power consumed by these circuits most or all of them can be switched to the residential generator for the duration of normal power interruption The wa...

Страница 11: ...average load factor of 80 of the standby rating The standby rating is only applicable for optional standby power where the generator set serves as the backup to the normal utility source Use the watt...

Страница 12: ...attery Door opening Provides access to starting battery and air cleaner E Oil Dip Stick Used to check the engine oil level F Engine Label Identifies engine model and type G Oil Fill Cap Remove to serv...

Страница 13: ...High performance muffler lowers engine noise to comply with most residential codes J Coolant Fill Door Provides access for servicing engine with oil and coolant K Oil Filter Filters engine oil to pro...

Страница 14: ...s blown melted open or was removed the engine cannot crank or start Replace the fuse using only an identical ATO 15A fuse E System Switch This two position switch is the most important control on the...

Страница 15: ...remain closed at all other times Each residential generator is equipped with two identical keys These keys fit the locks that secure the access doors To Open an Access Door 1 Insert key into lock of a...

Страница 16: ...unit in AUTO mode the battery receives a trickle charge while the engine is not running The trickle charge cannot be used to recharge a battery that is completely discharged 15 Amp Fuse The generator...

Страница 17: ...Maintenance Servicing the System To service the residential generator system 1 Remove 15 Amp fuse from control panel 2 Set control panel system switch to OFF 3 Set the generator s main circuit breake...

Страница 18: ...ct an Authorized Dealer Low Voltage Generator FC_3 This fault is indicated by fault code FC_3 and three blinks on the LED indicator This condition is caused by a restriction in the fuel flow a broken...

Страница 19: ...ructed in the operator s manual All adjustments should be made at least once each season Follow the requirements in the operator s manual Generator maintenance consists of keeping the unit clean Opera...

Страница 20: ...s for engine coolant are found in the engine operator s manual Battery Servicing of batteries are to be performed or supervised by personnel knowledgeable of batteries and the required precautions Kee...

Страница 21: ...To Clean the Generator notice Improper treatment of generator can damage it and shorten its life DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects t...

Страница 22: ...rvice facility 4 See Gaseous Fuel System in the Installation Manual 5 Remove kink Replace if necessary Engine will not start or starts and runs rough 1 15 Amp fuse missing or blown 2 Fuel supply turne...

Страница 23: ...er g to wear items such as oil gauges o rings filters fuses or spark plugs etc ADDITIONAL EXCLUSIONS UNDER COMMERCIAL APPLICATION 1 Wear items such as engine oil oil gauges o rings filters fuses spark...

Страница 24: ...und in your telephone directory or by contacting a RHEEM RUUD or PROTECH air conditioning distributor If necessary the following office can advise you of the nearest distributor 4744 Island Ford Road...

Страница 25: ...Reserved 25...

Страница 26: ...40 Volts 125 Amps Rated AC Voltage 120 240 Volts Phase Single phase Rated Frequency 60 Hertz Normal Operating Range 20 F 28 8 C to 104 F 40 C Output Sound Level 65 dB A at 23 ft 7 m at normal load Shi...

Отзывы: