Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual contains 

important instructions that should be followed during 

installation and maintenance of the generator and batteries. 
The safety alert symbol ( ) is used with a signal word 

(DANGER, CAUTION, WARNING), a pictorial and/or a safety 

message to alert you to hazards. 

DANGER

 indicates a 

hazard which, if not avoided, will result in death or serious 

injury. 

WARNING

 indicates a hazard which, if not avoided, 

could result in death or serious injury. 

CAUTION

 indicates 

a hazard which, if not avoided, might result in minor or 

moderate injury. 

NOTICE

 indicates a situation that could 

result in equipment damage. Follow safety messages to 

avoid or reduce the risk of injury or death.
The manufacturer cannot possibly anticipate every possible 

circumstance that might involve a hazard. The warnings in 

this manual, and the tags and decals affixed to the unit are, 

therefore, not all-inclusive. If you use a procedure, work 

method or operating technique that the manufacturer does 

not specifically recommend, you must satisfy yourself that 

it is safe for you and others. You must also make sure that 

the procedure, work method or operating technique that you 

choose does not render the generator system unsafe.

Hazard Symbols and Meanings

 WaRNING

Running engine gives off carbon monoxide, an 

odorless, colorless, poison gas.
Breathing carbon monoxide can cause 

headache, fatigue, dizziness, vomiting, 

confusion, seizures, nausea, fainting or death.

Operate generator ONLY outdoors.
Install a battery operated carbon monoxide alarm near 

the bedrooms.
Keep exhaust gas from entering a confined area through 

windows, doors, ventilation intakes, or other openings.


 WaRNING

Storage batteries give off explosive hydrogen 

gas during recharging.
Slightest spark will ignite hydrogen and 

cause explosion.
Battery electrolyte fluid contains acid and is 

extremely caustic.
Contact with battery contents will cause severe 

chemical burns.
A battery presents a risk of electrical shock and 

high short circuit current.

DO NOT dispose of battery in a fire. Recycle battery.
DO NOT allow any open flame, spark, heat, or lit cigarette 

during and for several minutes after charging a battery.
DO NOT open or mutilate the battery.
Wear protective goggles, rubber apron, rubber boots and 

rubber gloves.
Remove watches, rings, or other metal objects.
Use tools with insulated handles.




 WaRNING

The engine exhaust from this product contains 

chemicals known to the State of California 

to cause cancer, birth defects, or other 

reproductive harm.

 WaRNING

Certain components in this product and related 

accessories contain chemicals known to 

the State of California to cause cancer, birth 

defects, or other reproductive harm. Wash 

hands after handling.

Save These Instructions

Fire

Toxic Fumes

Explosive Pressure

Rotating Fan Blade

Lift Hazard

Read Manual

Exploding Battery

Rotating Belt/Pulley

Chemical Burn

Auto Start

Hot Surface

Rotating Parts

Electrical Shock

Explosion

Содержание GEN27WN

Страница 1: ...Questions Help is just a moment away Call Home Generator Helpline 877 369 9400 M F 8 5 CT Liquid Cooled Residential Generator System Operator s Manual GEN27WN GEN30WL GEN42WN GEN45WL...

Страница 2: ...id them Because Rheem does not necessarily know all the applications this equipment could be used for it is important that you read and understand these instructions thoroughly before attempting to st...

Страница 3: ...cuits 10 Delivery Inspection 11 Features and Controls 12 30 kW Residential Generator 12 45 kW Home Generator 13 System Control Panel 14 Operation 16 Automatic Operation 16 Setting Exercise Timer 17 Ma...

Страница 4: ...monoxide can cause headache fatigue dizziness vomiting confusion seizures nausea fainting or death Operate generator ONLY outdoors Install a battery operated carbon monoxide alarm near the bedrooms K...

Страница 5: ...he 15 Amp fuse BEFORE working on the equipment warning Propane and Natural Gas are extremely flammable and explosive Fire or explosion can cause severe burns or death Install the fuel supply system ac...

Страница 6: ...or can damage it and shorten its life Use generator only for intended uses If you have questions about intended use contact your authorized dealer Operate generator only on level surfaces Adequate uno...

Страница 7: ...Safety Label Locations 30kW...

Страница 8: ...Safety Label Locations 45kW...

Страница 9: ...with your system A thorough understanding of these options will provide some control over the cost of your installation as well as ensure your final satisfaction and security Federal and local codes...

Страница 10: ...to include as Essential Circuits Depending on the power consumed by these circuits most or all of them can be switched to the residential generator for the duration of normal power interruption The wa...

Страница 11: ...average load factor of 80 of the standby rating The standby rating is only applicable for optional standby power where the generator set serves as the backup to the normal utility source Use the watt...

Страница 12: ...attery Door opening Provides access to starting battery and air cleaner E Oil Dip Stick Used to check the engine oil level F Engine Label Identifies engine model and type G Oil Fill Cap Remove to serv...

Страница 13: ...High performance muffler lowers engine noise to comply with most residential codes J Coolant Fill Door Provides access for servicing engine with oil and coolant K Oil Filter Filters engine oil to pro...

Страница 14: ...s blown melted open or was removed the engine cannot crank or start Replace the fuse using only an identical ATO 15A fuse E System Switch This two position switch is the most important control on the...

Страница 15: ...remain closed at all other times Each residential generator is equipped with two identical keys These keys fit the locks that secure the access doors To Open an Access Door 1 Insert key into lock of a...

Страница 16: ...unit in AUTO mode the battery receives a trickle charge while the engine is not running The trickle charge cannot be used to recharge a battery that is completely discharged 15 Amp Fuse The generator...

Страница 17: ...Maintenance Servicing the System To service the residential generator system 1 Remove 15 Amp fuse from control panel 2 Set control panel system switch to OFF 3 Set the generator s main circuit breake...

Страница 18: ...ct an Authorized Dealer Low Voltage Generator FC_3 This fault is indicated by fault code FC_3 and three blinks on the LED indicator This condition is caused by a restriction in the fuel flow a broken...

Страница 19: ...ructed in the operator s manual All adjustments should be made at least once each season Follow the requirements in the operator s manual Generator maintenance consists of keeping the unit clean Opera...

Страница 20: ...s for engine coolant are found in the engine operator s manual Battery Servicing of batteries are to be performed or supervised by personnel knowledgeable of batteries and the required precautions Kee...

Страница 21: ...To Clean the Generator notice Improper treatment of generator can damage it and shorten its life DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects t...

Страница 22: ...rvice facility 4 See Gaseous Fuel System in the Installation Manual 5 Remove kink Replace if necessary Engine will not start or starts and runs rough 1 15 Amp fuse missing or blown 2 Fuel supply turne...

Страница 23: ...er g to wear items such as oil gauges o rings filters fuses or spark plugs etc ADDITIONAL EXCLUSIONS UNDER COMMERCIAL APPLICATION 1 Wear items such as engine oil oil gauges o rings filters fuses spark...

Страница 24: ...und in your telephone directory or by contacting a RHEEM RUUD or PROTECH air conditioning distributor If necessary the following office can advise you of the nearest distributor 4744 Island Ford Road...

Страница 25: ...Reserved 25...

Страница 26: ...40 Volts 125 Amps Rated AC Voltage 120 240 Volts Phase Single phase Rated Frequency 60 Hertz Normal Operating Range 20 F 28 8 C to 104 F 40 C Output Sound Level 65 dB A at 23 ft 7 m at normal load Shi...

Отзывы: