Generac Power Systems G0059395 Скачать руководство пользователя страница 3

INTRODUCTION

Thank you for purchasing this model by Generac Power Systems, 

Inc.  This model is a compact, high performance, air-cooled, 

engine driven generator designed to supply electrical power to 

operate electrical loads where no utility power is available or in 

place of utility due to a power outage.

READ THIS MANUAL THOROUGHLY

If any portion of this manual is not understood, contact the 

nearest Authorized Dealer for starting, operating and servicing 

procedures.
The operator is responsible for proper and safe use of the 

equipment. We strongly recommend that the operator read this 

manual and thoroughly understand all instructions before using the 

equipment. We also strongly recommend instructing other users to 

properly start and operate the unit. This prepares them if they need 

to operate the equipment in an emergency. Save these instructions 

for future reference. If you loan this device to someone, ALWAYS 

loan these instructions to the individual as well.
The generator can operate safely, efficiently and reliably only if it 

is properly located, operated and maintained. Before operating or 

servicing the generator:
•  Become familiar with and strictly adhere to all local, state and 

national codes and regulations.

• Study all safety warnings in this manual and on the product 

carefully.

•  Become familiar with this manual and the unit before use.
The manufacturer cannot anticipate every possible circumstance 

that might involve a hazard. The warnings in this manual, and on 

tags and decals affixed to the unit are, therefore, not all inclusive. 

If using a procedure, work method or operating technique that the 

manufacturer does not specifically recommend, ensure that it is 

safe for others. Also make sure the procedure, work method or 

operating technique utilized does not render the generator unsafe.
THE INFORMATION CONTAINED HEREIN WAS BASED ON 

MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION. 

GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT 

ANY TIME. 

SAFETY RULES

Throughout this publication, and on tags and decals affixed to the 

generator, DANGER, WARNING, CAUTION and NOTE blocks are 

used to alert personnel to special instructions about a particular 

operation that may be hazardous if performed incorrectly or 

carelessly. Observe them carefully. Their definitions are as 

follows:

INDICATES A HAZARDOUS SITUATION OR ACTION WHICH, IF 

NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.

Indicates a hazardous situation or action which, if not 

avoided, could result in death or serious injury.

Indicates a hazardous situation or action which, if not 

avoided, could result in minor or moderate injury.

NOTE:

Notes contain additional information important to a procedure 

and will be found within the regular text body of this manual.

These safety warnings cannot eliminate the hazards that they 

indicate. Common sense and strict compliance with the special 

instructions while performing the action or service are essential to 

preventing accidents.
Four commonly used safety symbols accompany the 

DANGER

WARNING

 and 

CAUTION

 blocks. The type of information each 

indicates is as follows:



 

This symbol points out important safety 
information that, if not followed, could 

endanger personal safety and/or property of 

others.

This symbol points out potential explosion 

hazard.

This symbol points out potential fire hazard.



This symbol points out potential electrical 
shock hazard.

GENERAL HAZARDS

• NEVER operate in an enclosed area, in a vehicle, or indoors 

EVEN IF doors and windows are open. 

• For safety reasons, the manufacturer recommends that the 

maintenance of this equipment is carried out by an Authorized 

Dealer. Inspect the generator regularly, and contact the nearest 

Authorized Dealer for parts needing repair or replacement.

•  Operate generator only on level surfaces and where it will not be 

exposed to excessive moisture, dirt, dust or corrosive vapors.

•  Keep hands, feet, clothing, etc., away from drive belts, fans, 

and other moving parts. Never remove any fan guard or shield 

while the unit is operating.

• Certain parts of the generator get extremely hot during 

operation. Keep clear of the generator until it has cooled to 

avoid severe burns.

•  Do NOT operate generator in the rain.
• Do not alter the construction of  the generator or change 

controls which might create an unsafe operating condition.

• Never start or stop the unit with electrical loads connected 

to receptacles AND with connected devices turned ON. Start 

the engine and let it stabilize before connecting electrical 

loads. Disconnect all electrical loads before shutting down the 

generator.

•  Do not insert objects through unit’s cooling slots.
• When working on this equipment, remain alert at all times. 

Never work on the equipment when physically or mentally 

fatigued.

Introduction

 

 

1

Содержание G0059395

Страница 1: ...or www generac com or 1 888 436 3722 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAVE this Manual Provide thi...

Страница 2: ...g Gasoline 9 2 8 Starting Pull Start Engines 10 2 9 Starting Electric Start Engines 10 2 10 Stopping the Engine 11 2 11 Low Oil Level Shutdown System 11 2 11 1 Sensing Low Oil Level 11 2 12 Charging t...

Страница 3: ...definitions are as follows INDICATES A HAZARDOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY Indicates a hazardous situation or action which if not avoided could re...

Страница 4: ...frame and external electrically conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult wi...

Страница 5: ...rc org Rural Electricity Resource Council P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Installation and Maintenance of Farm Standby Electric Power available from www asabe org American Society...

Страница 6: ...nd install the Frame Foot and Rubber Bumpers as shown Slide the Rubber Bumper studs through the Frame Foot then install the Locking Flange Nuts Slide the Hex Head Bolts through the holes in the Frame...

Страница 7: ...to drain engine oil 5 Air Filter Filters intake air as it is drawn into the engine 6 Choke Knob Used when starting a cold engine 7 Fuel Tank See generator Specifications for tank capacity 8 Grounding...

Страница 8: ...the meter is tracking hours of operation Figure 5 Hourmeter HOUR GLASS GRAPHIC RESET BUTTON IF EQUIPPED 0000 0 2 3 CORD SETS AND CONNECTION PLUGS 2 3 1 120 VAC 20 AMP DUPLEX RECEPTACLE This is a 120...

Страница 9: ...RTABLE This generator has an equipment ground that connects the generator frame components to the ground terminals on the AC output receptacles see NEC 250 34 A for explanation This allows the generat...

Страница 10: ...or does not give wattage multiply volts times ampere rating to determine watts volts x amps watts Some electric motors such as induction types require about three times more watts of power for startin...

Страница 11: ...GASOLINE Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Avoid spilling gasoline on a hot engine Allow engine to cool entirely before filling fuel tank DO NOT light a c...

Страница 12: ...d repeat starting instructions IMPORTANT Do not overload the generator Also do not overload individual panel receptacles These outlets are protected against overload with push to reset type circuit br...

Страница 13: ...hen the oil level drops below a specified level If the engine shuts down by itself and the fuel tank has enough gasoline check engine oil level 2 11 1 SENSING LOW OIL LEVEL If the system senses a low...

Страница 14: ...31 inch or 0 70 0 80 mm Gasoline Capacity 25 6 Liters 6 77 U S gallons Oil Type See Chart in Before Starting the Generator Section Oil Capacity 1 Liters 1 06 Qts Run Time at 50 Load 10 Hours 7 5kW Dis...

Страница 15: ...urns Allow engine to cool before draining oil Avoid prolonged or repeated skin exposure with used oil Thoroughly wash exposed areas with soap Use the following instructions to change the oil after the...

Страница 16: ...leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage...

Страница 17: ...9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Turn Fuel Shut off ON 2 Clean or replace air filter 3 Fill fuel tank 4 Drain fuel...

Страница 18: ...Manual Part No 0K0173 Rev B 01 24 13 Printed in China...

Страница 19: ...Manual Parte No 0K0173 Rev B 24 01 13 Impreso en China...

Страница 20: ...e combustible demasiado rica 11 V lvula de entrada atascada o cerrada 12 El motor ha perdido compresi n 1 Gire el cierre de combustible a ON 2 Limpie o reemplace el filtro de aire 3 Llene el tanque de...

Страница 21: ...urante el almacenamiento Los gases cidos pueden da ar el sistema de combustible de un motor durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vaciarse antes...

Страница 22: ...ta que el motor enfr e antes de drenar el aceite Evite una exposici n prolongada o repetida de la piel con el aceite usado Lave completamente las reas expuestas con jab n Use las siguientes instruccio...

Страница 23: ...84420101 Espaciamiento de la buj a 0 028 0 031 pulgadas o 0 70 0 80 mm Capacidad de gasolina 25 6 L 6 77 galones americanos Tipo de aceite Ver la cartilla en la secci n Antes de arrancar el generador...

Страница 24: ...forma autom tica cuando el nivel de aceite cae por debajo de un nivel especificado Si el motor se apaga y el tanque de combustible tiene suficiente gasolina revise el nivel de aceite de motor 2 11 1 S...

Страница 25: ...nerador Asimismo no sobrecargue los recept culos individuales Estas tomas est n protegidas contra sobrecargas con interruptores de circuito tipo presionar para reiniciar Si la corriente nominal de cua...

Страница 26: ...motor est funcionando o est caliente Evite derramar gasolina sobre un motor caliente Deje enfriar al motor completamente antes de llenar el tanque de combustible NO encienda cigarrillos o fume cuando...

Страница 27: ...es para determinar los vatios volts x amps vatios Algunos motores el ctricos como los del tipo inducci n requieren alrededor de tres veces m s potencia para arrancar que para funcionar Este transitori...

Страница 28: ...odore NE JAMAIS utiliser la g n ratrice l int rieur d une r sidence ou d un garage M ME SI les portes et les fen tres sont ouvertes Utiliser uniquement L EXT RIEUR et loin des fen tres portes et vents...

Страница 29: ...as horas de operaci n Figura 5 Hor metro GR FICO DE RELOJ DE ARENA BOT N DE REINICIO SI EST INSTALADO 0000 0 2 3 JUEGO DE CABLES Y CONECTORES 2 3 1 RECEPT CULO DUPLEX DE 120 VAC 20 AMP Esta es una tom...

Страница 30: ...el fin de proteger al generador contra sobrecargas el ctricas 4 Drenaje de aceite Usar para drenar el aceite del motor 5 Filtro de aire Filtra el aire de ingreso al motor 6 Palanca de choke Se le usa...

Страница 31: ...goma como se muestra Deslice los tacos del parachoques de goma a trav s de la pata del marco luego instale las contratuercas de cierre Deslice los pernos de cabeza hexagonal a trav s de los agujeros d...

Страница 32: ...rerc org Consejo de Recursos de Electricidad Rural P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Instalaci n y mantenimiento de energ a el ctrica de respaldo en granjas disponible en www asabe...

Страница 33: ...nas que son conductores el ctricos est n conectadas apropiadamente a una conexi n a tierra aprobada Los c digos el ctricos locales pueden asimismo requerir una apropiada conexi n a tierra del generado...

Страница 34: ...TRAER COMO RESULTADO LA MUERTE O UN DA O SERIO ADVERTENCIA Indica una situaci n peligrosa o acci n que si no se evita podr a traer como resultado la muerte o un da o serio CUIDADO Indica una situaci n...

Страница 35: ...Arranque de motores de recule 10 2 9 Arranque de motores con arranque el ctrico 10 2 10 Detener el Motor 11 2 11 Sistema de apagado por bajo nivel de aceite 11 2 11 1 Sensando el nivel de aceite 11 2...

Страница 36: ...ARANT A LIMITADA DOS A OS DOS A OS PELIGRO HUMOS DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO DISE ADO PARA SER USADO EN APLICACIONES DE SOPORTE D...

Отзывы: