6.  When the engine starts, move choke knob to “1/2 Choke” 

position until the engine runs smoothly and then fully in to the 

“Run” position. If engine falters, move choke knob back out to 

“1/2 Choke” position until the engine runs smoothly and then 

to “Run” position.

7.  This generator is also equipped with a manual recoil starter 

which may be used if the battery is discharged.

NOTE:

Use one of the generator’s receptacle panels along with 

the included battery charger to charge the battery while the 

generator is running.

NOTE:

The switch must be in the RUN position.

8.  To start manually, firmly grasp the recoil handle and pull 

slowly until increased resistance is felt. Pull rapidly up and 

away to start engine. Then follow the same choke sequence.

NOTE:

If engine fires, but does not continue to run, move choke lever 

to FULL CHOKE and repeat starting instructions.
IMPORTANT:

 Do not overload the generator. Also, do not overload 

individual panel receptacles. These outlets are protected against 

overload with push-to-reset-type circuit breakers. If amperage 

rating of any circuit breaker is exceeded, that breaker opens and 

electrical output to that receptacle is lost. Read “Don’t Overload the 

Generator” carefully.

2.10 STOPPING THE ENGINE

1.  Shut off all loads, then unplug the electrical loads from 

generator panel receptacles. Never start or stop the engine 

with electrical devices plugged in and turned on.

2.  Let engine run at no-load for several minutes to stabilize the 

internal temperatures of engine and generator.

3.  Move Run/Stop switch to OFF position.
4.  Close fuel valve.

2.11 LOW OIL LEVEL SHUTDOWN SYSTEM

The engine is equipped with a low oil level sensor that shuts down 

the engine automatically when the oil level drops below a specified 

level. If the engine shuts down by itself and the fuel tank has 

enough gasoline, check engine oil level.

2.11.1 SENSING LOW OIL LEVEL

If the system senses a low oil level during operation, the engine 

shuts down. The engine will not run until the oil has been refilled 

to the proper level.

2.12  CHARGING THE BATTERY (ELECTRIC START 

UNITS ONLY)



 

Storage batteries give off explosive hydrogen 

gas while recharging. An explosive mixture will 

remain around the battery for a long time after 

it has been charged. The slightest spark can 

ignite the hydrogen and cause an explosion. 

Such an explosion can shatter the battery and 

cause blindness or other serious injury.



 

Do not permit smoking, open flame, sparks 

or any other source of heat around a battery. 

Wear protective goggles, rubber apron and 

rubber gloves when working around a battery. 

Battery electrolyte fluid is an extremely 

corrosive sulfuric acid solution that can cause 

severe burns. If spill occurs flush area with 

clear water immediately. 

NOTE:

The battery shipped with the generator has been fully charged. 

A battery may lose some of its charge when not in use for 

prolonged periods of time. If the battery is unable to crank the 

engine, plug in the 12V charger included in the accessory box 

(see section "Charging the Battery"). RUNNING THE GENERATOR 

DOES NOT CHARGE THE BATTERY.

Use battery charger plug to keep the battery charged and ready for 

use. Battery charging should be done in a dry location.

1.  Plug charger into “Battery Charger Input” jack, located on the 

control panel. Plug wall receptacle end of the battery charger 

into a 120 Volt AC wall outlet (Figure 13).

2.  Unplug battery charger from wall outlet and control panel jack 

when generator is going to be in use.

NOTE:

Do not use the battery charger for more than 48 hours at one 

charge.

Figure 13 - Battery Charger Jack

BATTERY

CHARGER

INPUT

Operation

Содержание G0059395

Страница 1: ...or www generac com or 1 888 436 3722 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAVE this Manual Provide thi...

Страница 2: ...g Gasoline 9 2 8 Starting Pull Start Engines 10 2 9 Starting Electric Start Engines 10 2 10 Stopping the Engine 11 2 11 Low Oil Level Shutdown System 11 2 11 1 Sensing Low Oil Level 11 2 12 Charging t...

Страница 3: ...definitions are as follows INDICATES A HAZARDOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY Indicates a hazardous situation or action which if not avoided could re...

Страница 4: ...frame and external electrically conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult wi...

Страница 5: ...rc org Rural Electricity Resource Council P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Installation and Maintenance of Farm Standby Electric Power available from www asabe org American Society...

Страница 6: ...nd install the Frame Foot and Rubber Bumpers as shown Slide the Rubber Bumper studs through the Frame Foot then install the Locking Flange Nuts Slide the Hex Head Bolts through the holes in the Frame...

Страница 7: ...to drain engine oil 5 Air Filter Filters intake air as it is drawn into the engine 6 Choke Knob Used when starting a cold engine 7 Fuel Tank See generator Specifications for tank capacity 8 Grounding...

Страница 8: ...the meter is tracking hours of operation Figure 5 Hourmeter HOUR GLASS GRAPHIC RESET BUTTON IF EQUIPPED 0000 0 2 3 CORD SETS AND CONNECTION PLUGS 2 3 1 120 VAC 20 AMP DUPLEX RECEPTACLE This is a 120...

Страница 9: ...RTABLE This generator has an equipment ground that connects the generator frame components to the ground terminals on the AC output receptacles see NEC 250 34 A for explanation This allows the generat...

Страница 10: ...or does not give wattage multiply volts times ampere rating to determine watts volts x amps watts Some electric motors such as induction types require about three times more watts of power for startin...

Страница 11: ...GASOLINE Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Avoid spilling gasoline on a hot engine Allow engine to cool entirely before filling fuel tank DO NOT light a c...

Страница 12: ...d repeat starting instructions IMPORTANT Do not overload the generator Also do not overload individual panel receptacles These outlets are protected against overload with push to reset type circuit br...

Страница 13: ...hen the oil level drops below a specified level If the engine shuts down by itself and the fuel tank has enough gasoline check engine oil level 2 11 1 SENSING LOW OIL LEVEL If the system senses a low...

Страница 14: ...31 inch or 0 70 0 80 mm Gasoline Capacity 25 6 Liters 6 77 U S gallons Oil Type See Chart in Before Starting the Generator Section Oil Capacity 1 Liters 1 06 Qts Run Time at 50 Load 10 Hours 7 5kW Dis...

Страница 15: ...urns Allow engine to cool before draining oil Avoid prolonged or repeated skin exposure with used oil Thoroughly wash exposed areas with soap Use the following instructions to change the oil after the...

Страница 16: ...leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage...

Страница 17: ...9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Turn Fuel Shut off ON 2 Clean or replace air filter 3 Fill fuel tank 4 Drain fuel...

Страница 18: ...Manual Part No 0K0173 Rev B 01 24 13 Printed in China...

Страница 19: ...Manual Parte No 0K0173 Rev B 24 01 13 Impreso en China...

Страница 20: ...e combustible demasiado rica 11 V lvula de entrada atascada o cerrada 12 El motor ha perdido compresi n 1 Gire el cierre de combustible a ON 2 Limpie o reemplace el filtro de aire 3 Llene el tanque de...

Страница 21: ...urante el almacenamiento Los gases cidos pueden da ar el sistema de combustible de un motor durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vaciarse antes...

Страница 22: ...ta que el motor enfr e antes de drenar el aceite Evite una exposici n prolongada o repetida de la piel con el aceite usado Lave completamente las reas expuestas con jab n Use las siguientes instruccio...

Страница 23: ...84420101 Espaciamiento de la buj a 0 028 0 031 pulgadas o 0 70 0 80 mm Capacidad de gasolina 25 6 L 6 77 galones americanos Tipo de aceite Ver la cartilla en la secci n Antes de arrancar el generador...

Страница 24: ...forma autom tica cuando el nivel de aceite cae por debajo de un nivel especificado Si el motor se apaga y el tanque de combustible tiene suficiente gasolina revise el nivel de aceite de motor 2 11 1 S...

Страница 25: ...nerador Asimismo no sobrecargue los recept culos individuales Estas tomas est n protegidas contra sobrecargas con interruptores de circuito tipo presionar para reiniciar Si la corriente nominal de cua...

Страница 26: ...motor est funcionando o est caliente Evite derramar gasolina sobre un motor caliente Deje enfriar al motor completamente antes de llenar el tanque de combustible NO encienda cigarrillos o fume cuando...

Страница 27: ...es para determinar los vatios volts x amps vatios Algunos motores el ctricos como los del tipo inducci n requieren alrededor de tres veces m s potencia para arrancar que para funcionar Este transitori...

Страница 28: ...odore NE JAMAIS utiliser la g n ratrice l int rieur d une r sidence ou d un garage M ME SI les portes et les fen tres sont ouvertes Utiliser uniquement L EXT RIEUR et loin des fen tres portes et vents...

Страница 29: ...as horas de operaci n Figura 5 Hor metro GR FICO DE RELOJ DE ARENA BOT N DE REINICIO SI EST INSTALADO 0000 0 2 3 JUEGO DE CABLES Y CONECTORES 2 3 1 RECEPT CULO DUPLEX DE 120 VAC 20 AMP Esta es una tom...

Страница 30: ...el fin de proteger al generador contra sobrecargas el ctricas 4 Drenaje de aceite Usar para drenar el aceite del motor 5 Filtro de aire Filtra el aire de ingreso al motor 6 Palanca de choke Se le usa...

Страница 31: ...goma como se muestra Deslice los tacos del parachoques de goma a trav s de la pata del marco luego instale las contratuercas de cierre Deslice los pernos de cabeza hexagonal a trav s de los agujeros d...

Страница 32: ...rerc org Consejo de Recursos de Electricidad Rural P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Instalaci n y mantenimiento de energ a el ctrica de respaldo en granjas disponible en www asabe...

Страница 33: ...nas que son conductores el ctricos est n conectadas apropiadamente a una conexi n a tierra aprobada Los c digos el ctricos locales pueden asimismo requerir una apropiada conexi n a tierra del generado...

Страница 34: ...TRAER COMO RESULTADO LA MUERTE O UN DA O SERIO ADVERTENCIA Indica una situaci n peligrosa o acci n que si no se evita podr a traer como resultado la muerte o un da o serio CUIDADO Indica una situaci n...

Страница 35: ...Arranque de motores de recule 10 2 9 Arranque de motores con arranque el ctrico 10 2 10 Detener el Motor 11 2 11 Sistema de apagado por bajo nivel de aceite 11 2 11 1 Sensando el nivel de aceite 11 2...

Страница 36: ...ARANT A LIMITADA DOS A OS DOS A OS PELIGRO HUMOS DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO DISE ADO PARA SER USADO EN APLICACIONES DE SOPORTE D...

Отзывы: