![Generac Power Systems 0068210 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/generac-power-systems/0068210/0068210_owners-manual_2209828016.webp)
Maintenance and Troubleshooting
Owner’s Manual for Water Pump
14
Pump shuts
down during
operation.
1. No fuel.
2. Low oil sensor shuts down unit.
1. Allow engine to cool for 2 minutes,
then fill fuel tank.
2. Make sure unit is on flat surface.
Check oil level and add more if
necessary.
Oil leakage
at muffler or
air cleaner.
Engine failure.
Repair or replace.
Water
leakage
between
engine and
pump.
Damaged mechanical seal.
Replace mechanical seal.
* Mechanical seal damage may be caused by normal wear, overheating, or pumping
incompatible fluids.
** Excessive impeller wear is primarily due to cavitation. Causes include restricted suction and
excessive suction lift.
*** Total suction head should not exceed 26 ft (8 m).
PROBLEM
CAUSE