Genelec Loudspeaker Manager (GLM) 4 - System Operating Manual
page 35 of 87
The default setting (150Hz to 250Hz) should be suitable under most conditions, however, if
listening at particularly short distances, if the monitor is separated from the Adaptive
Woofer System (i.e. not mounted directly on top) or the WS is visually blocked by
obstruction (such as a large mixing desk), it may be beneficial to reduce the upper
crossover limit. Listening should be used determine if this is needed.
The crossover setting used will apply to all Adaptive Woofer Systems and main monitor
pairs active with the group.
4. Connect the measurement microphone to the GLM network adapter, place the microphone
at the listening position, at ear height, and Click on the ‘Start Calibration’ button to start the
measurement and follow the dialog instructions.
- All Adaptive Woofer Systems and monitors will be measured.
- Optimization starts.
- Wait until optimization finished.
- The calibration results can be viewed by clicking any loudspeaker icon.
5. Click ‘Confirm Calibration’ button to accept and save the calibration to the setup file.
Figure 20. Adaptive Woofer System calibration.
Description of the different operating modes:
The WS has 5 different calibration modes: Complementary, Continued directivity, and 3 null
modes.
Complementary:
1
2
3
3
4
5