Genelec Loudspeaker Manager (GLM) 4 - System Operating Manual
page 34 of 87
Figure 19. Steps in running the AutoPhase automatic phase calibration process
For more detailed information, see the section on Advanced use of AutoPhase.
5.5 Automatic Calibration of the Adaptive Woofer System GLM WooferCal
For a system containing Adaptive Woofer Systems (WS), the first part of the calibration (calibrating
the main monitor) is the same as that shown in Automatic Calibration Using GLM AutoCal.
Once that process has finished (providing WS are active in the group), you will be directed to the
Adaptive Woofer System calibration page.
1. The first step is to pair the monitors to the respective stands. This is done by first single-
clicking on the stand and then single-clicking on the monitor it should be paired with. This
process is repeated for all woofer monitor pairs in the Group. Once paired, the
pairing will continue to other Groups.
2. Firstly, the calibration mode is selected by using the drop-down menu – selecting between
Complementary, Continued directivity, or one of the three directivity null modes. Each
calibration mode or setting will require individual group to be created.
3. The parameters for setting the search limits for the crossover to the main monitor should
then be set. These controls are available for all modes except the Continued directivity
mode, where the crossover value is fixed based on the main monitor connected in the
pairing. This crossover has been set to where the main monitor and Adaptive Woofer
System have the closest matched directivity.