background image

2

System

The GENELEC 8040B and 8050B are 
two way active monitoring loudspeakers 
designed to produce high SPL output, low 
coloration and broad bandwidth in a small 
enclosure size. They are suitable for a wide 
variety of tasks, such as near field monitor-
ing, mobile vans, broadcast and TV control 
rooms, surround sound systems and home 
studios. Designed as active loudspeak-
ers, they contain drivers, power amplifiers, 
active crossover filters and protection cir-
cuitry. The Minimum Diffraction Enclosure™ 
(MDE™) and advanced Directivity Control 
Waveguide™ (DCW™) technologies provide 
excellent frequency balance even in difficult 
acoustic environments.

Drivers

The bass driver dimensions are 165 mm (6 
1/2”) and 205 mm (8”) for 8040B and 8050B 
respectively. The long, flow optimized reflex 
tube has a large cross sectional area and 
terminates with a wide flare at the back of 
the enclosure. The high frequency driver is a  
19 mm (3/4”) metal dome on the 8040B and 
a 25 mm (1”) metal dome on the 8050B. Both 
drivers are magnetically shielded.

Crossover

The active crossover network consists of two 
parallel bandpass filters. The crossover fre-
quency is 3.0 kHz on the 8040B and 1.8 kHz 
on the 8050B. The active crossover controls 
(“treble tilt”, “desktop low frequency”, “bass tilt” 
and “bass roll-off”) allow precise matching of 
the loudspeakers to any room environment. 

Amplifiers

The amplifier unit is mounted in the rear of the 
loudspeaker enclosure. The unit incorporates 
special circuitry for driver thermal overload 
protection. Variable input sensitivity allows 
accurate level matching to console output 
section.

Connections

Each loudspeaker is supplied with a mains 
cable and an operating manual. Before con-
necting up, ensure that the mains switch 
is off (see figure 1). Audio input is via a 
10 kOhm balanced XLR connector, but unbal-
anced leads may be used as long as pin 3 is 
grounded to pin 1 of the XLR (see figure 3). 
Once the connections have been made, the 
loudspeakers are ready to be switched on.

Mounting considerations

Align the loudspeakers correctly

Always place the loudspeakers so that 
their acoustic axes (see figure 2) are aimed 
towards the listening position. Vertical place-
ment is preferable, as it minimises acoustical 
cancellation problems around the crossover 
frequency.

Maintain symmetry

Check that the loudspeakers are placed sym-
metrically and at an equal distance from the 
listening position. If possible, place the system 
so that the listening position is on the center-
line of the room and the loudspeakers are 
placed at an equal distance from the center-
line. 

Minimise reflections

Acoustic reflections from objects close to the 
loudspeakers like desks, cabinets, computer 
monitors etc. can cause unwanted colouration 
and blurring of the sound image. These can be 
minimised by placing the loudspeaker clear of 
reflective surfaces. For instance, putting the 
loudspeakers on stands behind and above the 
mixing console usually gives a better result 
than placing them on the meter bridge.

Genelec 8040B and 8050B Active Monitoring Systems

Содержание 8040B

Страница 1: ...8040B 8050B Operating Manual 2 6 Käyttöohje 7 11 ...

Страница 2: ...osure The unit incorporates special circuitry for driver thermal overload protection Variable input sensitivity allows accurate level matching to console output section Connections Each loudspeaker is supplied with a mains cable and an operating manual Before con necting up ensure that the mains switch is off see figure 1 Audio input is via a 10 kOhm balanced XLR connector but unbal anced leads ma...

Страница 3: ...ill automatically and rapidly start once an input signal is detected from the source Setting the tone controls The frequency response of the system may also have to be adjusted to match the acous tic environment The adjustment is carried out by setting the three tone control switch groups treble tilt bass tilt and bass roll off on the rear panel of the amplifier There is also a special desktop low...

Страница 4: ...al safety standards to ensure safe operation and to maintain the loudspeaker under safe operating conditions the following warnings and cautions must be observed Servicing and adjustment must only be performed by qualified service personnel The loudspeaker must not be opened Do not use this product with an unearthed mains cable as this may lead to personal injury To prevent fire or electric shock ...

Страница 5: ...igure 7 The curves above show the effect of the bass tilt treble tilt desktop low frequency and bass roll off controls on the free field response of the 8040B Figure 8 The upper curve group shows the horizontal directivity characteristics of the 8040B measured at 1 m The lower curve shows the system s power response Figure 9 The curves above show the effect of the bass tilt treble tilt desktop low...

Страница 6: ...16 452 mm 17 13 16 286 mm 11 1 4 278 mm 10 15 16 8040B 8050B Bass amplifier short term output power Treble amplifier short term output power Long term output power is limited by driver unit protection circuitry 90 W 90 W 150 W 120 W Amplifier system distortion at nominal output THD SMPTE IM CCIF IM DIM 100 0 05 0 05 0 05 0 05 0 05 0 05 0 05 0 05 Signal to Noise ratio referred to full output Bass T...

Страница 7: ...iuttimet sisältävät kaiutinelementteihin suoraan kytketyt päätevahvistimet 8040B n molemmat vahvis timet ovat teholtaan 90 wattia 8050B ssa on diskanttielementille 120 watin ja bassoelemen tille 150 watin vahvistin Kaiutinkotelon sisään rakennetut vahvistimet on varustettu automaat tisilla suojapiireillä kaiutinelementtien ylikuu menemisen varalta Vahvistimien säädettävä sisääntuloherkkyys mahdoll...

Страница 8: ...fonitelineeseen jossa on 3 8 UNC kierre Herkkyyden säätö Kaiuttimien ottoliitännän herkkyys on sää dettävissä erilaisille äänilähteille sopivaksi Kuva 1 8040B n takapaneeli Kuva 2 Akustisen akselin sijainti Kuva 3 RCA XLR signaalikaapelin kytkentä ON www genelec com 8040B BI AMPLIFIED MONITORING SYSTEM MAINS INPUT 50 60 Hz 110 W 230 V MADE IN FINLAND MAGNETICALLY SHIELDED INPUT SENSITIVITY REQUIRE...

Страница 9: ...niteltu ja valmistettu täyttämään kansainväliset turval lisuusnormit Virheellisestä käytöstä saattaa kuitenkin seurata vaaratilanne joten seuraa via ohjeita on aina noudatettava Laitetta ei saa asettaa alttiiksi kosteudelle tai roiskevedelle Se on tarkoitettu käytettäväksi ainoastaan kuivassa huonetilassa Huolto ja korjaustoimia saa suorittaa vain valmistajan valtuuttama huoltohenkilöstö Älä avaa ...

Страница 10: ... 95 d B r A 100 90 95 20 20k 50 100 200 500 1k 2k 5k 10k Hz Genelec Oy 8050 dBr vs freq Hz 6 Apr 04 80 85 90 d B r A BASS ROLL OFF TREBLE TILT 80 85 90 80 85 90 DESKTOP LF BASS TILT Kuva 7 Bass tilt treble tilt desktop low frequency ja bass roll off säätöjen vaikutus 8040B n vapaakenttävasteeseen Kuva 8 Ylempi käyrästö kuvaa 8040B n suuntaavuuskäyttäytymistä 1 metrin mittausetäisyydellä Alempi käy...

Страница 11: ...237 mm 9 3 8 223 mm 8 13 16 433 mm 17 1 16 452 mm 17 13 16 286 mm 11 1 4 278 mm 10 15 16 8040B 8050B Bassovahvistimen lyhytkestoinen maksimiteho Diskanttivahvistimen lyhytkestoinen maksimiteho Jatkuvaa tehoa rajoittaa kaiutin elementtien suojauselektroniikka 90 W 90 W 150 W 120 W Vahvistimien särö nimellisteholla THD SMPTE IM CCIF IM DIM 100 0 05 0 05 0 05 0 05 0 05 0 05 0 05 0 05 Kohinaetäisyys t...

Страница 12: ...tact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Jianwai SOHO Tower 12 Room 2605 D 1504 Chaoyang District Beijing 100022 China Phone 86 10 8580 2180 Fax 86 10 8580 2181 Email genelec china genelec com In Sweden please contact Genelec Sverige Ellipsvägen 10B P O Box 5521 S 14...

Отзывы: