8.4 Seat Adjustment
•
In case of very low sensitivity due to the actuator working at its maximum load
limit, turn the Seat Adjuster clockwise. If the equipment keeps oscillating, turn
counter-clockwise until balance is achieved. Be careful not to loosen the Lock
Screw since it might come off the Seat Adjuster.
•
In case of oscillation due to mounting with a low air capacity actuator, refer to
section 8.5.
8.5 Air throttle in pilot valve
In case of low air capacity actuators, there could be oscillation in the equipment,
rendering it inoperative. In such a case, use air throttles in outputs OUT1 and OUT2 of
the pilot valve. There are two available measures that come with the equipment:
Actuator Volume
Output Orifice Diameter
Smaller than 90 cm
3
Ø 0,7
Between 90 ~ 180 cm
3
Ø 1,0
Bigger than 180 cm
3
None
Attention: This adjustment is done in the factory so it is not
necessary to readjust later.
ATTENTION! This adjustment must only be performed by qualified
technicians. Otherwise the equipment might completely lose its
configuration.