ENC-3300-DTMF
Power
The ENC-3300 operates from 11 to 14 volts DC.
A power cord attaches to connector J7 which is 2.1mm x 5mm in size and uses a
CENTER PIN
POSITIVE
configuration.
A 2 amp, 5mm x 20mm glass fuse is used for electrical protection and safety.
Radio Interface
Input / Output Connector
Connector J3 is used for connections to radios and other external devices.
A larger version of the Output Schematic is available on page 44.
Genave/NRC,Inc. 9000-0000-086 rev 4