  2.3 Set: (Pressing this button to set the value from ~40%~45%~50%~55%~60%~

   

65%~70%~75%~80%~continuing dehumdifying,circularlly

   

Remark: The humidity just can be set when humdity setting indicator is lighting.

   

• Pressing 1st to make the machine from continuing dehumidifying mode to 

   

  the 40%RH(target humidity), continuing dehumidifying indicator lamp 

   

  crushing out and setting indicator lamp lighting up. When the Room 

   

  humidity is lower 1%RH than setted humidity,compressor stop working 

   

  and fan operating in low level. Then if the Room humidity is higher 

   

  5%RH than set humidity, compressor recover working and fan start 

   

  working in high or low speed level.

   

• Pressing settting button 2nd time to make the machine’s target humidity 

   

  from 40%RH turn to 45%RH. When temperature and humidity sensor test 

   

  Room humidity ≤1%RH than set humidity(45%RH), the compressor 

   

  doesn’t work and fan turn to low-speed level to operate. When product test 

   

  Room humidity ≥5%RH,compressor does work and fan operate in high 

   

  or low speed level. When the set humidity is in 50%RH, 55%RH, 60%RH, 

   

  65%RH, 70%RH, 75%RH, 80%RH, its operation procedure is same with above.

 

   

• Pressing Set button 10th time to make it from digit-tube from 80%RH turn to 

   

  continuing dehumidifying mode, and humidity setting indicator lamp  crushing 

   

  out and continuing indicator lamp lighting, digit-tube indicate Room

   

  humidity, compressor working and fan operating in high or low speed level.

   

• Pressing “Set” button in 11th time,it will circularly like above.

 

 

Remark:

   

① 

The machine can memory previous working mode when outage suddenly and then powerd on; 

   

② 

When setting humidity, if we don’t do any operating within 3s,machin will turn to indicate 

   

  Room temperature value;

   

③ 

Pressing humidity set button for 5s to indicate Room humidity value, if you pressing 

   

  humidity setted button all the time, display will indicate Room temperature value all; 

   

  Pressing humidity button 5s to indicate Room temperature value, if move hand,it will indicate 

   

  Room humidity value; 

   

④ 

If product test the Room is 5%RH will change which it’s the Room humidty value indicated 

   

  on digit double 8, when Room humidity value is lower 30%RH, digit tube will indicateLO, 

   

  when Room humidity higher 90%RH, it will indicate HI;

   

⑤ 

When automatic dehumidifying indicator lighting, pressing humidity setting button 1st time, 

   

  digit-tube indicate present set humidity value; pressing humidity button 2nd time, it indicate

   

  setted humidity value;

   

⑥ 

When compressor operating and fan operating in low-speed level, temperature and humidity 

   

  sensor test Room temperature value ≥32℃, fan motor turn to operate on high-speed level 

   

  automatically and fan motor high-speed level indicator is lighting, and it is functioning when 

   

  pressing wind-speed level, but the output won’t change and stop on button 2s, then fan

   

  high-speed level indicator lighting, if product test Room temperature≤30℃, it will turn back to 

   

  original working model.

 

Operating introduction

P9

Содержание GD20SS

Страница 1: ...GD20SS Dehumdifier User s Manual ...

Страница 2: ...el Key Pads Operation of Key Pads Automatic Defrosting Water Full Protect Function Compressor Stop Start Working Function Low High Temperature Protection Function Failures Of Humidity Temperature Sensor Refrigerant leakage Test Function Maintenances Cleaning Specification Table 3 5 6 7 8 8 11 12 12 13 13 13 13 14 15 Index ...

Страница 3: ...ctrical shock do not place it in near window or in bathroom 3 Please ensure the unit is not placed closely to the high temperature appliance in case of plastic destroying and fire 4 Never operate this unit in an explosive or corrosive atmosphere 5 Always guide if children operate Never disassemble the unit and never try to carry out repairs or adjust the unit yourself 6 Operate this unit on a hori...

Страница 4: ...e is 30 cm of clear space on all sides of the unit 9 Make sure the inlet and outlet ventilation is not blocked at all times 10 Do not spray water on the unit spraying water may cause malfunctioning and electric shock 11 Never pull the socket by using damp hands 12 Always switch off at the socket before unplugging to avoid electric shock or arcing ...

Страница 5: ...eservoir when not using the unit for a long time 14 Do not pull power wire by force because it will cause damage to power wire 15 Never put fingers or other objects in any openings of the unit 16 When moving this machine please remove the water tank and empty the water in order to avoid water leakage ...

Страница 6: ...room etc Never use it in wet environment or outdoors 3 Make sure the door and window are closed before turning on the unit 4 Ensure that the unit is placed on a stable and flat floor surface If the floor surface is not even there is a risk that the unit may be unstable and topple over Also excessive vibration and noise may be result P6 ...

Страница 7: ...Components Diagrams P7 Control panel Louver Removable Filter cover Handle Water tank ...

Страница 8: ...n high speed and circularly like this Remark If the machine is setted on the low speed level and compressor is operating when the Room temperature is 32 the fan motor will turn to high level automatically the fan motor s high speed level s indicator s lamp is lighting and wind speed s button is functioning but the output won t be changed and the high speed level indicator lamp will light and keep ...

Страница 9: ...essor working and fan operating in high or low speed level Pressing Set button in 11th time it will circularly like above Remark The machine can memory previous working mode when outage suddenly and then powerd on When setting humidity if we don t do any operating within 3s machin will turn to indicate Room temperature value Pressing humidity set button for 5s to indicate Room humidity value if yo...

Страница 10: ...tarting to close swing If we start swing within 15 minutes it will cancel above function Once start swing function the circular movement will be canceled automatically Once swing function is closed it will swing up 25 then swing down 25 to stop circularly 2 5 Timer button Reserving timing time Setting timing powering on or off 00H 01H 02H 03H 04H 11H 12H 00H circularly Timing powering on automatic...

Страница 11: ...indicate no timing setting if we set timing time 01H 02H 03H 04H 11H 12H the timing indicator is lighting it indicate timing setting We can set the powering ON time when it s under standly mode and can set powering OFF time when it s under working When the setted time arrived the machine will stop working immediately and stepping motor will turn down clockwise to make air plate close 100 If the se...

Страница 12: ...buzzer warn 10 times the buzzer will stop warning Water ful switch cut off the stepping motor will turn down clockwise move 100 Except ON OFF button the other button is not useable and also no buzzer Operating introduction P12 If the temperature sensor test temperature of evaporator s copper tube 1 compressor will continue working 30 minutes and then it will stop working product will defrost the i...

Страница 13: ... of humidity and temperature sensor breaks off the symbol of continuous dehumidification Cont will wink It doesn t work when pressing humidity setting button but other function is well The appliance comes into continuous dehumidifying mode 8 Refrigerent leakage test function The compressor will test the temperature of temperature and humdity sensor and NTC of evaporator s copper tube in every 8 mi...

Страница 14: ...ff and unplug the unit Before moving the unit please switch off and unplug the unit If not using the unit for a long time Please switch off and unplug the unit empty the water reservoir and pack it after 2 days then keep it in dry and ventilated place Please seek help from your dealers or the professionals if there are some problems with the appliance We will not be responsible for damage or hurts...

Страница 15: ...P15 MODEL RATED VOLTAGE RATED FREQUENCY RATED INPUT CAPACITY REFRIGERANT HIGH PRESSURE LOW PRESSURE MAX PERMITED PRESSURE GD20SS 220 240V 50Hz 250W 26 7 60 RH 20L D 30 80 RH 12L D 26 7 60 RH R134a 155g 1 5MPa 0 4Mpa 1 9MPa ...