2.3 Set: (Pressing this button to set the value from ~40%~45%~50%~55%~60%~
65%~70%~75%~80%~continuing dehumdifying,circularlly
Remark: The humidity just can be set when humdity setting indicator is lighting.
• Pressing 1st to make the machine from continuing dehumidifying mode to
the 40%RH(target humidity), continuing dehumidifying indicator lamp
crushing out and setting indicator lamp lighting up. When the Room
humidity is lower 1%RH than setted humidity,compressor stop working
and fan operating in low level. Then if the Room humidity is higher
5%RH than set humidity, compressor recover working and fan start
working in high or low speed level.
• Pressing settting button 2nd time to make the machine’s target humidity
from 40%RH turn to 45%RH. When temperature and humidity sensor test
Room humidity ≤1%RH than set humidity(45%RH), the compressor
doesn’t work and fan turn to low-speed level to operate. When product test
Room humidity ≥5%RH,compressor does work and fan operate in high
or low speed level. When the set humidity is in 50%RH, 55%RH, 60%RH,
65%RH, 70%RH, 75%RH, 80%RH, its operation procedure is same with above.
• Pressing Set button 10th time to make it from digit-tube from 80%RH turn to
continuing dehumidifying mode, and humidity setting indicator lamp crushing
out and continuing indicator lamp lighting, digit-tube indicate Room
humidity, compressor working and fan operating in high or low speed level.
• Pressing “Set” button in 11th time,it will circularly like above.
Remark:
①
The machine can memory previous working mode when outage suddenly and then powerd on;
②
When setting humidity, if we don’t do any operating within 3s,machin will turn to indicate
Room temperature value;
③
Pressing humidity set button for 5s to indicate Room humidity value, if you pressing
humidity setted button all the time, display will indicate Room temperature value all;
Pressing humidity button 5s to indicate Room temperature value, if move hand,it will indicate
Room humidity value;
④
If product test the Room is 5%RH will change which it’s the Room humidty value indicated
on digit double 8, when Room humidity value is lower 30%RH, digit tube will indicateLO,
when Room humidity higher 90%RH, it will indicate HI;
⑤
When automatic dehumidifying indicator lighting, pressing humidity setting button 1st time,
digit-tube indicate present set humidity value; pressing humidity button 2nd time, it indicate
setted humidity value;
⑥
When compressor operating and fan operating in low-speed level, temperature and humidity
sensor test Room temperature value ≥32℃, fan motor turn to operate on high-speed level
automatically and fan motor high-speed level indicator is lighting, and it is functioning when
pressing wind-speed level, but the output won’t change and stop on button 2s, then fan
high-speed level indicator lighting, if product test Room temperature≤30℃, it will turn back to
original working model.