5. Compressor stop/start working function:

  When the machine is operating,any operation can cause compressor stop 

  working.And machine will turn to protection funtion of compressor stop 

  working 3 minutes and then start up,the other function is normal.

6. Low&High temperature protection function:

  When temperature and humdity sensor test Room temperature≤0℃ or ≥40℃ 

  and the sensor’s NTC disconnection or short circuit, compressor and fan motor 

  haven’t output, buzzer warning all the time and there is no reflection when 

  pressing any button, and it just will be effective after switch ON anew.

7. Failures Of Humidity&Temperature Sensor:

  When the connect wire of humidity and temperature sensor breaks off, the 

  symbol of continuous dehumidification ”Cont” will wink. It doesn’t work 

  when pressing humidity setting button, but other function is well. 

  The appliance comes into continuous dehumidifying mode.

8. Refrigerent leakage test function:

  The compressor will test the temperature of temperature and humdity sensor 

  and NTC of evaporator’s copper tube in every 8 minutes; If compressor test the 

  temperature different value is ≤3℃ between temperature and humidity sensor 

  and evaporator’s NTC successive 2 times, then it indicates abnormal, digit tube 

  blink (lightening 1s and extinguishing 1s) 

Operating introduction

P13

If the machine is under dehumidifying or refrigerating,fetching out water tank 

or switching OFF and then switching ON, interval time should reach 3 minutes,

and then machine will start dehumidifying.

Содержание GD20SS

Страница 1: ...GD20SS Dehumdifier User s Manual ...

Страница 2: ...el Key Pads Operation of Key Pads Automatic Defrosting Water Full Protect Function Compressor Stop Start Working Function Low High Temperature Protection Function Failures Of Humidity Temperature Sensor Refrigerant leakage Test Function Maintenances Cleaning Specification Table 3 5 6 7 8 8 11 12 12 13 13 13 13 14 15 Index ...

Страница 3: ...ctrical shock do not place it in near window or in bathroom 3 Please ensure the unit is not placed closely to the high temperature appliance in case of plastic destroying and fire 4 Never operate this unit in an explosive or corrosive atmosphere 5 Always guide if children operate Never disassemble the unit and never try to carry out repairs or adjust the unit yourself 6 Operate this unit on a hori...

Страница 4: ...e is 30 cm of clear space on all sides of the unit 9 Make sure the inlet and outlet ventilation is not blocked at all times 10 Do not spray water on the unit spraying water may cause malfunctioning and electric shock 11 Never pull the socket by using damp hands 12 Always switch off at the socket before unplugging to avoid electric shock or arcing ...

Страница 5: ...eservoir when not using the unit for a long time 14 Do not pull power wire by force because it will cause damage to power wire 15 Never put fingers or other objects in any openings of the unit 16 When moving this machine please remove the water tank and empty the water in order to avoid water leakage ...

Страница 6: ...room etc Never use it in wet environment or outdoors 3 Make sure the door and window are closed before turning on the unit 4 Ensure that the unit is placed on a stable and flat floor surface If the floor surface is not even there is a risk that the unit may be unstable and topple over Also excessive vibration and noise may be result P6 ...

Страница 7: ...Components Diagrams P7 Control panel Louver Removable Filter cover Handle Water tank ...

Страница 8: ...n high speed and circularly like this Remark If the machine is setted on the low speed level and compressor is operating when the Room temperature is 32 the fan motor will turn to high level automatically the fan motor s high speed level s indicator s lamp is lighting and wind speed s button is functioning but the output won t be changed and the high speed level indicator lamp will light and keep ...

Страница 9: ...essor working and fan operating in high or low speed level Pressing Set button in 11th time it will circularly like above Remark The machine can memory previous working mode when outage suddenly and then powerd on When setting humidity if we don t do any operating within 3s machin will turn to indicate Room temperature value Pressing humidity set button for 5s to indicate Room humidity value if yo...

Страница 10: ...tarting to close swing If we start swing within 15 minutes it will cancel above function Once start swing function the circular movement will be canceled automatically Once swing function is closed it will swing up 25 then swing down 25 to stop circularly 2 5 Timer button Reserving timing time Setting timing powering on or off 00H 01H 02H 03H 04H 11H 12H 00H circularly Timing powering on automatic...

Страница 11: ...indicate no timing setting if we set timing time 01H 02H 03H 04H 11H 12H the timing indicator is lighting it indicate timing setting We can set the powering ON time when it s under standly mode and can set powering OFF time when it s under working When the setted time arrived the machine will stop working immediately and stepping motor will turn down clockwise to make air plate close 100 If the se...

Страница 12: ...buzzer warn 10 times the buzzer will stop warning Water ful switch cut off the stepping motor will turn down clockwise move 100 Except ON OFF button the other button is not useable and also no buzzer Operating introduction P12 If the temperature sensor test temperature of evaporator s copper tube 1 compressor will continue working 30 minutes and then it will stop working product will defrost the i...

Страница 13: ... of humidity and temperature sensor breaks off the symbol of continuous dehumidification Cont will wink It doesn t work when pressing humidity setting button but other function is well The appliance comes into continuous dehumidifying mode 8 Refrigerent leakage test function The compressor will test the temperature of temperature and humdity sensor and NTC of evaporator s copper tube in every 8 mi...

Страница 14: ...ff and unplug the unit Before moving the unit please switch off and unplug the unit If not using the unit for a long time Please switch off and unplug the unit empty the water reservoir and pack it after 2 days then keep it in dry and ventilated place Please seek help from your dealers or the professionals if there are some problems with the appliance We will not be responsible for damage or hurts...

Страница 15: ...P15 MODEL RATED VOLTAGE RATED FREQUENCY RATED INPUT CAPACITY REFRIGERANT HIGH PRESSURE LOW PRESSURE MAX PERMITED PRESSURE GD20SS 220 240V 50Hz 250W 26 7 60 RH 20L D 30 80 RH 12L D 26 7 60 RH R134a 155g 1 5MPa 0 4Mpa 1 9MPa ...

Страница 16: ......

Отзывы: