2. Operation Of Key Pads:

  When plug into power socket,all the LED indicator lamp on control panel and 

  digit-display lighting 1s then crushing out,the buzzer warning 2 times.

 

  2.1  On/Off: (control turn on/off)

   

(water tank full switch is on closed condition)

   

• Pressing On/Off button to start up the machine,the buzzer warning 

   

  3times, fan and compressor will start up, high level speed lamp will 

   

  light and digit-display tube indicate Room humidity value, 

   

  continuing dehumidifying indicator lamp lighting and machine is 

   

  going to continuing dehumidifying, stepping motor will turn up 

   

  95°(anticlockwise).

   

• Pressing On/Off button to switch off, the buzzer will warn 3 times, 

   

  then it will switch off all the output and indication, stepping motor 

   

  will turn down 100°(clockwise), then stop.

 2.2 Fan: (Pressing 1st time, machine will operate in low level, pressing 

   

2nd time to operate in high speed; and circularly like this.

   

Remark:

   

① 

If the machine is setted on the low speed level and compressor is operating, when the 

   

  Room temperature is ≥32℃ , the fan motor will turn to high-level automatically, the fan 

   

  motor’s high-speed level’s indicator’s lamp is lighting and wind speed’s button is 

   

  functioning, but the output won’t be changed and the high-speed level indicator lamp will 

   

  light and keep it; when Room temperature ≤30℃,machine will turn back original setting 

   

  mode automatically.

   

② 

When the machine is defrosting,fan motor will operate in high speed level all the time, and 

   

  corresponding indicator is lighting.

1. On/Off: Switch on/off the power.

2. Fan: Pressing the button to set high or low level

3. Set: Pressing the button to set target Room humidity, you can set: 40%RH, 45%RH, 50%RH, 

  55%RH, 60%RH, 65%RH, 70%RH, 75%RH, 80%RH and continuing operation.

4. Swing: Pressing the button to set swing.    

5. Timer: Pressing the button to set reserve off time, you can set 0H, 1H, 2H, 3H, 4H, 5H … 9H, 10H, 

  11H and 12H.

Operating introduction

P8

1.  Functions of Control Panel & Key Pads

Содержание GD20SS

Страница 1: ...GD20SS Dehumdifier User s Manual ...

Страница 2: ...el Key Pads Operation of Key Pads Automatic Defrosting Water Full Protect Function Compressor Stop Start Working Function Low High Temperature Protection Function Failures Of Humidity Temperature Sensor Refrigerant leakage Test Function Maintenances Cleaning Specification Table 3 5 6 7 8 8 11 12 12 13 13 13 13 14 15 Index ...

Страница 3: ...ctrical shock do not place it in near window or in bathroom 3 Please ensure the unit is not placed closely to the high temperature appliance in case of plastic destroying and fire 4 Never operate this unit in an explosive or corrosive atmosphere 5 Always guide if children operate Never disassemble the unit and never try to carry out repairs or adjust the unit yourself 6 Operate this unit on a hori...

Страница 4: ...e is 30 cm of clear space on all sides of the unit 9 Make sure the inlet and outlet ventilation is not blocked at all times 10 Do not spray water on the unit spraying water may cause malfunctioning and electric shock 11 Never pull the socket by using damp hands 12 Always switch off at the socket before unplugging to avoid electric shock or arcing ...

Страница 5: ...eservoir when not using the unit for a long time 14 Do not pull power wire by force because it will cause damage to power wire 15 Never put fingers or other objects in any openings of the unit 16 When moving this machine please remove the water tank and empty the water in order to avoid water leakage ...

Страница 6: ...room etc Never use it in wet environment or outdoors 3 Make sure the door and window are closed before turning on the unit 4 Ensure that the unit is placed on a stable and flat floor surface If the floor surface is not even there is a risk that the unit may be unstable and topple over Also excessive vibration and noise may be result P6 ...

Страница 7: ...Components Diagrams P7 Control panel Louver Removable Filter cover Handle Water tank ...

Страница 8: ...n high speed and circularly like this Remark If the machine is setted on the low speed level and compressor is operating when the Room temperature is 32 the fan motor will turn to high level automatically the fan motor s high speed level s indicator s lamp is lighting and wind speed s button is functioning but the output won t be changed and the high speed level indicator lamp will light and keep ...

Страница 9: ...essor working and fan operating in high or low speed level Pressing Set button in 11th time it will circularly like above Remark The machine can memory previous working mode when outage suddenly and then powerd on When setting humidity if we don t do any operating within 3s machin will turn to indicate Room temperature value Pressing humidity set button for 5s to indicate Room humidity value if yo...

Страница 10: ...tarting to close swing If we start swing within 15 minutes it will cancel above function Once start swing function the circular movement will be canceled automatically Once swing function is closed it will swing up 25 then swing down 25 to stop circularly 2 5 Timer button Reserving timing time Setting timing powering on or off 00H 01H 02H 03H 04H 11H 12H 00H circularly Timing powering on automatic...

Страница 11: ...indicate no timing setting if we set timing time 01H 02H 03H 04H 11H 12H the timing indicator is lighting it indicate timing setting We can set the powering ON time when it s under standly mode and can set powering OFF time when it s under working When the setted time arrived the machine will stop working immediately and stepping motor will turn down clockwise to make air plate close 100 If the se...

Страница 12: ...buzzer warn 10 times the buzzer will stop warning Water ful switch cut off the stepping motor will turn down clockwise move 100 Except ON OFF button the other button is not useable and also no buzzer Operating introduction P12 If the temperature sensor test temperature of evaporator s copper tube 1 compressor will continue working 30 minutes and then it will stop working product will defrost the i...

Страница 13: ... of humidity and temperature sensor breaks off the symbol of continuous dehumidification Cont will wink It doesn t work when pressing humidity setting button but other function is well The appliance comes into continuous dehumidifying mode 8 Refrigerent leakage test function The compressor will test the temperature of temperature and humdity sensor and NTC of evaporator s copper tube in every 8 mi...

Страница 14: ...ff and unplug the unit Before moving the unit please switch off and unplug the unit If not using the unit for a long time Please switch off and unplug the unit empty the water reservoir and pack it after 2 days then keep it in dry and ventilated place Please seek help from your dealers or the professionals if there are some problems with the appliance We will not be responsible for damage or hurts...

Страница 15: ...P15 MODEL RATED VOLTAGE RATED FREQUENCY RATED INPUT CAPACITY REFRIGERANT HIGH PRESSURE LOW PRESSURE MAX PERMITED PRESSURE GD20SS 220 240V 50Hz 250W 26 7 60 RH 20L D 30 80 RH 12L D 26 7 60 RH R134a 155g 1 5MPa 0 4Mpa 1 9MPa ...

Страница 16: ......

Отзывы: