Gemini GD20SS Скачать руководство пользователя страница 11

  2.4  Swing button: (controlling the swing confition) 

      • When the machine is working,pressing air-plate to make stepping motor 

         ON/OFF, the corresponding swing indicator lamp light/quenching. 

         Stepping motor turn down(anticlockwise) to make air- plate turn 45°, then

         turn up(anti-clockwise) to make air-plate turn 45°, then turn down(clockwise) 

         to make air-plate 45°, circularly like this.

      • If we pressing”Swing”button to let it stop after stepping motor is working, 

         then pressing”Swing”button again to make stepping motor turn up(anti-

         clockwise) to let air-plate turning 95°, then turn down (clockwise) to let air 

         plate turning 45°, then turning up(anti-clockwise) 45°, circularly like this. 

      • When powering on, stepping motor open 95°anti-clockwise, then stop, if 

         we don’t start swing function, the stepping motor will close 25°1 time, 

         then open 25°to stop in every 15 minutes, (and stepping motor’s turning 

         speed is faster 2 times than original.

      • When powering on,the stepping motor will open 95°(anti-clockwise), then 

         stop; if we start swing function and then close,stepping motor will close 

         25°clockwise 1 time and then open 25°anti-clockwise to stop in every 

         15 minutes, (stepping motor’s turning speed is fater 2 times than original).                                  

         Remark:

     

   ① 

It is 15 minutes from starting to close swing,

     

   ② 

If we start swing within 15 minutes, it will cancel above function,

     

   ③ 

Once start swing function, the circular movement will be canceled automatically,

     

   ④ 

Once swing function is closed, it will swing up 25°, then swing down 25° to stop circularly

  2.5  Timer button: Reserving timing time. (Setting timing powering on or off: 

      00H, 01H, 02H, 03H, 04H…11H, 12H, 00H circularly)

      • Timing powering on automatically condition:

         -

 

Powering on,pressing timing button to set timing powering on 00H, 

           01H, 02H, 03H, 04H......11H, 12H, 00H, the digit tube is blinking to 

           indicate it is in the state of timing powering on setting, it will turn into 

           indicating time of timing powering on if don’t set timing, and as times 

           goes by, it will indicate preset remaining time.

         Remark:

     

   ① 

When preset timing time is 00H,timing indicator lamp is not lighted(it indicates no setting 

           timing function), if we set timing time is 01H, 02H, 03H, 04H……11H, 12H, timing indicator 

           lamp is lighting(it indicate having setting timing function);

     

   ② 

If we preset the timing powering on time when machine is under standby mode and preset 

           the timing powering off time when machine is working;

     

   ③ 

When timing powering on is arriving, stepping motor will turn up 95°(anti-clockwise), 

           then stop, and machine will memorise previous working mode;

     

   ④ 

In the standby mode, pressing timing button and ON/OFF will operate and the buzzer 

           will warn, there is no reaction when pressing other button

         -

 

When powering on, if the machine has been already set timing 

           powering on time, and then if you set timing powering on time again, 

           the timing will be increased from the data of preset remaining time, and 

           if you don’t set again within 3s, it will turn to indicate timing powering 

           on time, and as times goes by, it will indicate preset remaining time.

      • Timing powering OFF:

         -  When the machine is operating, pressing timer button to set powering 

           OFF time from 00H, 01H, 02H, 03H, 04H......11H, 12H, 00H, the digit 

           tube blinking indicate the condition of powering OFF setting, if we don’t 

           set within 3s, it will turn to indicate Room humidity value.

         Remark:

         

  When setting the timing is 00H, the timing indicator lamp is not lighting(it indicate no 

           timing setting), if we set timing time 01H, 02H, 03H, 04H……11H, 12H, the timing indicator 

           is lighting(it indicate timing setting); 

         

  We can set the powering ON time when it’s under standly mode,and can set powering OFF 

           time when it’s under working. 

         

  When the setted time arrived,the machine will stop working immediately and stepping 

           motor will turn down(clockwise) to make air-plate close 100°;

         

  If the setted time is not arrived,water full switch will be closed,machine recover to work 

           as per before water-full switch cut off; 

         

  As times goes by,it will indicate preset remaining time

  

         -  When the machine is under operating, if the timing powering on is 

           set, the data will increased from preset remaining time if we set 

           powering OFF time anew, and digit-tube is blinking to indicate timing 

           powering OFF is being setted. If we don’t operate within 3s, display 

           will turn to indicate Room value.

Operating introduction

P11

Содержание GD20SS

Страница 1: ...GD20SS Dehumdifier User s Manual ...

Страница 2: ...el Key Pads Operation of Key Pads Automatic Defrosting Water Full Protect Function Compressor Stop Start Working Function Low High Temperature Protection Function Failures Of Humidity Temperature Sensor Refrigerant leakage Test Function Maintenances Cleaning Specification Table 3 5 6 7 8 8 11 12 12 13 13 13 13 14 15 Index ...

Страница 3: ...ctrical shock do not place it in near window or in bathroom 3 Please ensure the unit is not placed closely to the high temperature appliance in case of plastic destroying and fire 4 Never operate this unit in an explosive or corrosive atmosphere 5 Always guide if children operate Never disassemble the unit and never try to carry out repairs or adjust the unit yourself 6 Operate this unit on a hori...

Страница 4: ...e is 30 cm of clear space on all sides of the unit 9 Make sure the inlet and outlet ventilation is not blocked at all times 10 Do not spray water on the unit spraying water may cause malfunctioning and electric shock 11 Never pull the socket by using damp hands 12 Always switch off at the socket before unplugging to avoid electric shock or arcing ...

Страница 5: ...eservoir when not using the unit for a long time 14 Do not pull power wire by force because it will cause damage to power wire 15 Never put fingers or other objects in any openings of the unit 16 When moving this machine please remove the water tank and empty the water in order to avoid water leakage ...

Страница 6: ...room etc Never use it in wet environment or outdoors 3 Make sure the door and window are closed before turning on the unit 4 Ensure that the unit is placed on a stable and flat floor surface If the floor surface is not even there is a risk that the unit may be unstable and topple over Also excessive vibration and noise may be result P6 ...

Страница 7: ...Components Diagrams P7 Control panel Louver Removable Filter cover Handle Water tank ...

Страница 8: ...n high speed and circularly like this Remark If the machine is setted on the low speed level and compressor is operating when the Room temperature is 32 the fan motor will turn to high level automatically the fan motor s high speed level s indicator s lamp is lighting and wind speed s button is functioning but the output won t be changed and the high speed level indicator lamp will light and keep ...

Страница 9: ...essor working and fan operating in high or low speed level Pressing Set button in 11th time it will circularly like above Remark The machine can memory previous working mode when outage suddenly and then powerd on When setting humidity if we don t do any operating within 3s machin will turn to indicate Room temperature value Pressing humidity set button for 5s to indicate Room humidity value if yo...

Страница 10: ...tarting to close swing If we start swing within 15 minutes it will cancel above function Once start swing function the circular movement will be canceled automatically Once swing function is closed it will swing up 25 then swing down 25 to stop circularly 2 5 Timer button Reserving timing time Setting timing powering on or off 00H 01H 02H 03H 04H 11H 12H 00H circularly Timing powering on automatic...

Страница 11: ...indicate no timing setting if we set timing time 01H 02H 03H 04H 11H 12H the timing indicator is lighting it indicate timing setting We can set the powering ON time when it s under standly mode and can set powering OFF time when it s under working When the setted time arrived the machine will stop working immediately and stepping motor will turn down clockwise to make air plate close 100 If the se...

Страница 12: ...buzzer warn 10 times the buzzer will stop warning Water ful switch cut off the stepping motor will turn down clockwise move 100 Except ON OFF button the other button is not useable and also no buzzer Operating introduction P12 If the temperature sensor test temperature of evaporator s copper tube 1 compressor will continue working 30 minutes and then it will stop working product will defrost the i...

Страница 13: ... of humidity and temperature sensor breaks off the symbol of continuous dehumidification Cont will wink It doesn t work when pressing humidity setting button but other function is well The appliance comes into continuous dehumidifying mode 8 Refrigerent leakage test function The compressor will test the temperature of temperature and humdity sensor and NTC of evaporator s copper tube in every 8 mi...

Страница 14: ...ff and unplug the unit Before moving the unit please switch off and unplug the unit If not using the unit for a long time Please switch off and unplug the unit empty the water reservoir and pack it after 2 days then keep it in dry and ventilated place Please seek help from your dealers or the professionals if there are some problems with the appliance We will not be responsible for damage or hurts...

Страница 15: ...P15 MODEL RATED VOLTAGE RATED FREQUENCY RATED INPUT CAPACITY REFRIGERANT HIGH PRESSURE LOW PRESSURE MAX PERMITED PRESSURE GD20SS 220 240V 50Hz 250W 26 7 60 RH 20L D 30 80 RH 12L D 26 7 60 RH R134a 155g 1 5MPa 0 4Mpa 1 9MPa ...

Страница 16: ......

Отзывы: