background image

13

Operation Manual

Toll Free: 800-635-0289  •  Email: [email protected]  •    Web: www.ametekfactoryautomation.com

Chapter 4: Certification and Warranty

The factory certifies that the Gemco Series 1999 Semelex II Safetimeter has been inspected and tested at the factory 
prior to shipment and meets requirements defined by the contract under which it is furnished.

All products of the factory are warranted against defective material and workmanship for a period of one year from 
the date of delivery. The factory will repair or replace, at their option, all defective equipment returned (transportation 
charges prepaid) during the warranty period without charge, provided there is no evidence that the equipment has 
been mishandled or abused. This warranty does not apply to expendable parts or materials whose normal life is 
less than the warranty period, nor is the factory liable for consequential damages arising out of use or handling of its 
products.

4.1: Annual Calibration

Semelex Safetimeter is a safety device that is used to measure 
stopping time and calculating safety distances.  It is highly 
recommended that the device be returned to the AMETEK factory 
on an annual basis for inspections and calibration.  There is a sticker 
on the inside panel that will show when your unit is due for its next 
calibration.  To start the calibration process, simply send an email to 

[email protected]

 to request a Return Material Authorization 

(RMA) Number.

4.2: Optional 5 Year Warranty - (1999OPT5YRWRNTY)

The Semelex II Safetimeter Optional Five Year Limited Warranty Limited Warranty Plan Includes:

1. 

  Limited Warranty  Seller warrants its products against defects in workmanship and materials of the items 

purchased under this order provided, however, that notice of such defect is received in writing by Seller within 
five years from the date of delivery of the item under this order. Seller’s liability under this clause is restricted to 
replacing, repairing, or issuing credit (at Seller’s option) for any return unit and only under the following conditions: 
(1) Seller must be properly notified in writing as soon as possible after the defects have been noted by the 
customer, but no later than five years from date of delivery. (2) The defective merchandise is to be returned to 
place of manufacture; shipping charges prepaid by the customer. (3) Our inspection of the returned units shall 
disclose to our satisfaction that the units were defective in workmanship or material at the time of delivery. 
ALL OTHER WARRANTIES, FOR ANY OF SELLER’S PRODUCTS, EXPRESS OR IMPLIED, STATUTORY OR 
OTHERWISE, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR 
FITNESS FOR PURPOSE ARE EXCLUDED.

2.   

Four Annual Re-Calibrations  Annual factory re-calibrations of the units are required to ensure accuracy of test 
results. Under the conditions stated in the above warranty, the Seller will provide four (4) annual re-calibrations 
of the unit, at no charge, during the life of the warranty (1 per year, during the 5 year extended warranty period).
Shipping of the unit to and from the manufacturer for re-calibration is the responsibility of the customer.

Содержание Semelex Safetimeter 1999 Series

Страница 1: ...Semelex Safetimeter Operating Manual Series 1999 1999SEMC SELF CONTAINED PORTABLE ELECTRONIC STOP TIME METER...

Страница 2: ...st Presses Running in a Continuous Mode 11 3 9 Set Press Counterbalance 12 3 10 Test Full Revolution Clutch Presses 12 Chapter 4 Certification and Warranty 13 4 1 Annual Calibration 13 4 2 Optional 5...

Страница 3: ...ime Ts from 1 9999 milliseconds It also calculates the minimum safety distance Ds based on the OSHA formula as understood by the factory and will display up to 999 9 inches to the nearest 0 1 inches T...

Страница 4: ...MANUAL START jack on the Safetimeter panel and are used to manually start the Safetimeter timing Remote Tachometer with Magnetic Base The tachometer replaces the P V Transducer when testing high speed...

Страница 5: ...e switch should be in the TIME UP position when checking press top stop STOP TIME mSEC SAFETY DISTANCE IN This switch is used to select the display mode either time or distance Time is measured in mil...

Страница 6: ...verify systems the Auto Flag can be used Chapter 2 Unpack Set up The Series 1999 Semelex II Safetimeter has been carefully inspected and tested before shipment Unpack the unit and perform a visual ins...

Страница 7: ...switch 14 If the optional Manual Start Switch is available continue with steps 14 15 If not move to Chapter 3 Operating Instructions 15 Plug the Manual Start Switch in the MANUAL Start jack If the Saf...

Страница 8: ...e Safetimeter begins to count The number displayed in the CSP dial is the distance between the base of the P V transducer and the ram 7 Subtract 1 2 of the press stroke from the number displayed in th...

Страница 9: ...top command is given This switch must be properly set even when a manual test with the optional manual start switch is performed NOTE The Gemco Semelex II Safetimeter has the capability to check both...

Страница 10: ...iate a press stop NOTE The Auto Hand can only release 10 lbs of force and may not release if pushed against the button with excessive force In this case use one leg as a spacer to prevent applying exc...

Страница 11: ...ting a press stop NOTE During this test verify that when the press stops the dies have not fully engaged and the press has not gone through the bottom of its stroke If either situation occurs increase...

Страница 12: ...ded NOTE If the shaft rotation viewed by the tachometer is clockwise toggle the TIME UP TIME DOWN switch to TIME UP If the shaft rotation is counterclockwise toggle the switch to TIME DOWN Toggle the...

Страница 13: ...play as desired Timing Direction TIME DOWN Revolution PART REV 5 Press the Safetimeter power switch OFF 6 Start the press in continuous mode 7 Observe that the press is up to speed 8 When the ram is o...

Страница 14: ...point Always follow the press manufacturer s recommendations when setting the counterbalance Several safety distance and or stop time tests must be performed after the setting of the counterbalance to...

Страница 15: ...r Warranty 1999OPT5YRWRNTY The Semelex II Safetimeter Optional Five Year Limited Warranty Limited Warranty Plan Includes 1 Limited Warranty Seller warrants its products against defects in workmanship...

Страница 16: ...uipment Includes 1 Safetimeter SD0500901 1 P V Transducer SD0500400 1 Auto Hand SD0502200 1 Auto Flag SD0502100 1 Cable Extension Set 1 2 4 SD0500300 1 Auto Hand Plunger Extension 04579042 3 Auto Hand...

Страница 17: ...ttery Battery Type 6 Volt sealed lead acid Operating Time Full Charge 10 hours Continuous Between Charges 3 5 Days Typical On Off Recharge Time 8 Hours Mechanical Safetimeter Case Highly Visible Yello...

Страница 18: ...Unparalleled flexibility Gear reducers and multipliers Timing dials Provisions for other sensors 2110 SHUT HEIGHT MONITOR Interfaces with our LDT s and Resolver Use as a simple indicator of position...

Отзывы: