background image

380V  AC

IN

R

S

N

T

12V

AC

12V

AC

1

3

5

13

2

4

6

14

R

S

T

PUMP

380V  AC

OUT

12V AC

OUT

380V

50-60Hz

IN / Girifl

3 PHASE

3.2 kW

M

R

S

N

T

PE

PE

6

3. ELECTRICITY CONNECTION SCHEME

15

14

13

12

11

10

9

8

7

1

2

3

4

5

6

1 PHASE

2.2 kW

M

220V/12V

TRANSFORMER

220V/230V

50-60Hz

IN

220V-230V / 5A

50-60Hz

OUT

LAMP

EXTERNAL

CONTROL

BUTTON

PUMP

EXTERNAL

CONTROL

BUTTON

Maximum 1.0 kW auxiliary products.
2.2 kW pumps and 1.0 kW lights can
be connected to the device.

Electricity connection scheme of connectors inside panel (MONO Phase)

Electricity connection scheme of connectors inside panel (THREE Phase)

1

2

3

4

5

6

7

8

L

N

L

N

12V

AC

12V

AC

220V  AC

IN

220V  AC

OUT

12V  AC

OUT

220V/230V

50-60Hz

IN / Girifl

PE

1 PHASE

2.2 kW

M

PE

Содержание MONO

Страница 1: ...INSTALLATION INSTRUCTION MANUAL KURULUM VE KULLANIM KILAVUZU POOL CONTROL MONO POOL KONTROL MONO ...

Страница 2: ...ke sure that the device is installed and connected correctly See electric connection diagrams at the back of this booklet At installation to setup the device for the first time it is necessary to set the main clock time calibrate the pump ampere current and select the operating modes for each device to be controlled e g Continuous ON continuous OFF or Automatic timer controlled If the device is to...

Страница 3: ...oll through the program setting options until Sett is shown on the main display Press the dial button to ENTER The display then flashes to show the hours By turning the dial button the minutes hours can be changed Then the dial button must be pressed again to save the Time clock setting Turn the dial button anticlockwise to return to the Homepage 3 Pump AMP Calibration for pump protection Menu ite...

Страница 4: ... is shown on the main display Press the dial button to ENTER in order to switch between the 3 modes The display then flashes By turning the setting button you can switch between the 3 modes modes To confirm a chosen press the dial button again L On Lights output is on mode continuously Previous scheduled timer programs will not apply L OFF Lights output is off mode continuously Previous scheduled ...

Страница 5: ... be pressed again to save the Timer OFF setting LIGHTS ON Time In OFF mode turn the Settings dial button CLOCKWISE until the LED for Lights timer ON is lit green Press the dial button to ENTER The display then flashes to show the hours minutes By turning the dial button the minutes hours can be changed in 5 minute increments Then the dial button must be pressed again to save the Timer ON setting L...

Страница 6: ...230V 50 60Hz IN 220V 230V 5A 50 60Hz OUT LAMP EXTERNAL CONTROL BUTTON PUMP EXTERNAL CONTROL BUTTON Maximum 1 0 kW auxiliary products 2 2 kW pumps and 1 0 kW lights can be connected to the device Electricity connection scheme of connectors inside panel MONO Phase Electricity connection scheme of connectors inside panel THREE Phase 1 2 3 4 5 6 7 8 L N L N 12V AC 12V AC 220V AC IN 220V AC OUT 12V AC ...

Страница 7: ...taj ve ba lant lar do ru bir flekilde yap ld na emin olduktan sonra cihaza enerji verilir ve cihaz kapal konuma off al n r Cihaz n ilk kurulumunda saat ayar pompan n kalibre edilmesi ve cihaz n ç k fllar n n hangi modda olaca n n belirlenmesi gerekir Cihaz otomatik modda çal flt r lmak isteniyor ise içerisindeki zamanlay c lar n aç lma ve kapanma saatlerinin ayarlanmas gerekecektir aksi takdirde ciha...

Страница 8: ... ifade edilir Butona bas larak ayar k sm na girilir Ekranda cihaza tan mlanan saat ve dakika yan p söndü ü görünür Buton çevrilerek dakikalar de ifltirilip saat ayar yap l r arkas ndan butona tekrar bas larak ayar kaydedilir 3 Pompa Kalibrasyonu Pompan n kalibrasyonu cihaz n ilk kurulumunda veya herhangi bir nedenle pompa de ifltirildi inde bir defaya mahsus yap lmaktad r Pompan n kalibrasyonu yap l...

Страница 9: ...al flma modu menüde 14 s rada bulunan AUX Çal flma Modu Ayar Bölümünden ayarlanmaktad r Ekranda A On A OFF A OtO ifadelerinden biri bulunmaktad r Bu ifade AUX ç k fl n n çal flma modunu göstermektedir Mod de iflikli i yapmak için butona bas l r Ekrandaki ifade yan p sönmeye bafllar Ayar butonu çevrilerek modlar aras geçifl yap l r Tekrar butona basarak seçilen mod kaydedilir A On AUX ç k fl sürekli aç k k...

Страница 10: ... be pressed again to save the Timer OFF setting LIGHTS ON Time In OFF mode turn the Settings dial button CLOCKWISE until the LED for Lights timer ON is lit green Press the dial button to ENTER The display then flashes to show the hours minutes By turning the dial button the minutes hours can be changed in 5 minute increments Then the dial button must be pressed again to save the Timer ON setting L...

Страница 11: ...0V 230V 50 60Hz IN 220V 230V 5A 50 60Hz OUT LAMP EXTERNAL CONTROL BUTTON PUMP EXTERNAL CONTROL BUTTON Pompa ç k fl na en fazla 10A Lamba ç k fl na en fazla 6A AUX ç k fl na en fazla 6A ak m çekecek yükler ba lanmal d r Pano çi Klemensleri Elektrik Ba lant fiemas MONO Phase Pano çi Klemensleri Elektrik Ba lant fiemas THREE Phase 1 2 3 4 5 6 7 8 L N L N 12V AC 12V AC 220V AC IN 220V AC OUT 12V AC OUT 220...

Страница 12: ... We reserve to change all of the articles or contents of this document without prior notice Firmam z bu belgenin içeri inde haber vermeksizin de ifliklikler yapabilir ...

Отзывы: