background image

4- Setting Device Operation Modes

Pump, Lights and AUX outputs of the device can be set to operate with different
independent mode settings. Therefore, it is required to define the individual
operating modes for each item.

Continuous ON / Continuous OFF / OtO - Automatic 

(OtO - operating with

pre-set timer settings)

For Pump output operating mode: - (Menu item 12)

The Pool Control Mono needs to be in ‘OFF’ mode to access settings. In OFF
mode, turn the Settings dial/button CLOCKWISE to scroll through the program
setting options until Pump Mode is reached - either 

P.On / P.OFF / P.OtO

 is

shown on the main display. Press the dial/button to ENTER in order to
switch between the 3 modes. The display then flashes.
By turning the setting button, you can switch between the 3 modes modes.
To confirm a chosen, press the dial/button again.

P.On:

 Pump output is “on mode” continuously. Previous scheduled timer

programs will not apply.

P.OFF:

 Pump output is “off mode” continuously. Previous scheduled timer

programs will not apply.

P.OtO:

 Pump output is “OtO” (automatic). The Pump operates according to

scheduled timer programs.

For Light output operating mode: - (Menu item 13)

The Pool Control Mono needs to be in ‘OFF’ mode to access settings. In OFF
mode, turn the Settings dial/button CLOCKWISE to scroll through the program
setting options until Light Mode is reached - either 

L.On / L.OFF / L.OtO

 is

shown on the main display. Press the dial/button to ENTER in order to switch
between the 3 modes. The display then flashes.
By turning the setting button, you can switch between the 3 modes modes.
To confirm a chosen, press the dial/button again.

L.On:

 Lights output is “on mode” continuously. Previous scheduled timer

programs will not apply.

L.OFF:

 Lights output is “off mode” continuously. Previous scheduled timer

programs will not apply.

L.OtO:

 Lights output is “OtO” (automatic). The Pool Lights operates according

to scheduled timer programs.

For Auxiliary Item AUX output operating mode: - (Menu item 14)

The Pool Control Mono needs to be in ‘OFF’ mode to access settings. In OFF
mode, turn the Settings dial/button CLOCKWISE to scroll through the program
setting options until Auxiliary Mode is reached - either 

A.On / A.OFF / A.OtO

is shown on the main display. Press the dial/button to ENTER in order to
switch between the 3 modes. The display then flashes.
By turning the setting button, you can switch between the 3 modes modes.
To confirm the required mode, press the Settings dial/button again.

A.On:

 Auxiliary item output is “on mode” continuously. Previous scheduled

timer programs will not apply.

A.OFF:

 Auxiliary item output is “off mode” continuously. Previous scheduled

timer programs will not apply.

A.OtO:

 Auxiliary item output is “OtO” (automatic). The Auxiliary item operates

according to scheduled timer programs.

If you wish to use the “OtO” mode for Pump, Lights and/or AUX. You
will need to set Startup/On and Shut down/Off times for these items
individually as follows:

4

Содержание MONO

Страница 1: ...INSTALLATION INSTRUCTION MANUAL KURULUM VE KULLANIM KILAVUZU POOL CONTROL MONO POOL KONTROL MONO ...

Страница 2: ...ke sure that the device is installed and connected correctly See electric connection diagrams at the back of this booklet At installation to setup the device for the first time it is necessary to set the main clock time calibrate the pump ampere current and select the operating modes for each device to be controlled e g Continuous ON continuous OFF or Automatic timer controlled If the device is to...

Страница 3: ...oll through the program setting options until Sett is shown on the main display Press the dial button to ENTER The display then flashes to show the hours By turning the dial button the minutes hours can be changed Then the dial button must be pressed again to save the Time clock setting Turn the dial button anticlockwise to return to the Homepage 3 Pump AMP Calibration for pump protection Menu ite...

Страница 4: ... is shown on the main display Press the dial button to ENTER in order to switch between the 3 modes The display then flashes By turning the setting button you can switch between the 3 modes modes To confirm a chosen press the dial button again L On Lights output is on mode continuously Previous scheduled timer programs will not apply L OFF Lights output is off mode continuously Previous scheduled ...

Страница 5: ... be pressed again to save the Timer OFF setting LIGHTS ON Time In OFF mode turn the Settings dial button CLOCKWISE until the LED for Lights timer ON is lit green Press the dial button to ENTER The display then flashes to show the hours minutes By turning the dial button the minutes hours can be changed in 5 minute increments Then the dial button must be pressed again to save the Timer ON setting L...

Страница 6: ...230V 50 60Hz IN 220V 230V 5A 50 60Hz OUT LAMP EXTERNAL CONTROL BUTTON PUMP EXTERNAL CONTROL BUTTON Maximum 1 0 kW auxiliary products 2 2 kW pumps and 1 0 kW lights can be connected to the device Electricity connection scheme of connectors inside panel MONO Phase Electricity connection scheme of connectors inside panel THREE Phase 1 2 3 4 5 6 7 8 L N L N 12V AC 12V AC 220V AC IN 220V AC OUT 12V AC ...

Страница 7: ...taj ve ba lant lar do ru bir flekilde yap ld na emin olduktan sonra cihaza enerji verilir ve cihaz kapal konuma off al n r Cihaz n ilk kurulumunda saat ayar pompan n kalibre edilmesi ve cihaz n ç k fllar n n hangi modda olaca n n belirlenmesi gerekir Cihaz otomatik modda çal flt r lmak isteniyor ise içerisindeki zamanlay c lar n aç lma ve kapanma saatlerinin ayarlanmas gerekecektir aksi takdirde ciha...

Страница 8: ... ifade edilir Butona bas larak ayar k sm na girilir Ekranda cihaza tan mlanan saat ve dakika yan p söndü ü görünür Buton çevrilerek dakikalar de ifltirilip saat ayar yap l r arkas ndan butona tekrar bas larak ayar kaydedilir 3 Pompa Kalibrasyonu Pompan n kalibrasyonu cihaz n ilk kurulumunda veya herhangi bir nedenle pompa de ifltirildi inde bir defaya mahsus yap lmaktad r Pompan n kalibrasyonu yap l...

Страница 9: ...al flma modu menüde 14 s rada bulunan AUX Çal flma Modu Ayar Bölümünden ayarlanmaktad r Ekranda A On A OFF A OtO ifadelerinden biri bulunmaktad r Bu ifade AUX ç k fl n n çal flma modunu göstermektedir Mod de iflikli i yapmak için butona bas l r Ekrandaki ifade yan p sönmeye bafllar Ayar butonu çevrilerek modlar aras geçifl yap l r Tekrar butona basarak seçilen mod kaydedilir A On AUX ç k fl sürekli aç k k...

Страница 10: ... be pressed again to save the Timer OFF setting LIGHTS ON Time In OFF mode turn the Settings dial button CLOCKWISE until the LED for Lights timer ON is lit green Press the dial button to ENTER The display then flashes to show the hours minutes By turning the dial button the minutes hours can be changed in 5 minute increments Then the dial button must be pressed again to save the Timer ON setting L...

Страница 11: ...0V 230V 50 60Hz IN 220V 230V 5A 50 60Hz OUT LAMP EXTERNAL CONTROL BUTTON PUMP EXTERNAL CONTROL BUTTON Pompa ç k fl na en fazla 10A Lamba ç k fl na en fazla 6A AUX ç k fl na en fazla 6A ak m çekecek yükler ba lanmal d r Pano çi Klemensleri Elektrik Ba lant fiemas MONO Phase Pano çi Klemensleri Elektrik Ba lant fiemas THREE Phase 1 2 3 4 5 6 7 8 L N L N 12V AC 12V AC 220V AC IN 220V AC OUT 12V AC OUT 220...

Страница 12: ... We reserve to change all of the articles or contents of this document without prior notice Firmam z bu belgenin içeri inde haber vermeksizin de ifliklikler yapabilir ...

Отзывы: