![Gema OptiGun GA03-E Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/gema/optigun-ga03-e/optigun-ga03-e_operating-instructions-and-spare-parts-list_2206658023.webp)
V 02/22
OptiGun GA03-E
Initial start-up
•
21
Start-up and powder coating
WARNING
Dangerous discharges.
If not grounded parts within 5 m of the coating booth are sufficient
charged, this can cause dangerous discharges.
► All electrically conductive parts within 5 m of the coating booth
must be grounded!
1.
Check the powder fluidization
2.
The installed gun must be pointed towards a grounded work piece in
the coating booth
3.
Switch on the gun control unit
4.
Adjust the coating parameters or select one of the programs. Check
by observing the LED displays.
5.
The workpieces can be coated now
Shut-down
1.
Switch off the powder gun control unit. The adjustments for high
voltage, powder output volume and electrode rinsing air remain
stored.
2.
If working interruptions take place, such as lunch time, night time etc.
disconnect the main compressed air supply
Содержание OptiGun GA03-E
Страница 24: ......
Страница 29: ...V 02 22 OptiGun GA03 E Cleaning and maintenance 27 7 8 9 10 ...
Страница 30: ...V 02 22 28 Cleaning and maintenance OptiGun GA03 E 11 12 13 14 ...
Страница 32: ......
Страница 41: ...V 02 22 OptiGun GA03 E Spare parts list 39 Nozzle combinations Fig 13 OptiGun GA03 E Nozzle combinations ...