V 02/22
OptiGun GA03-E
Initial start-up
•
19
Setting the powder quantity
The powder output volume is selected in reference to the desired layer
thickness. The selection is done on the control unit. For the beginning, the
standard adjustment of 60% is recommended. The total air volume is
thereby kept constant automatically.
The powder output depends on the powder type and the adjusted
total air volume (see therefore the control unit operating manual).
much powder
little powder
To achieve maximum efficiency, we recommend avoided an over-
ly high powder volume where possible!
Setting the electrode rinsing air
1.
Select the correct electrode rinsing
≈ 0.1 Nm³/h
≈ 0.5 Nm³/h
too much electrode rinsing air
2.
Adjust the powder cloud with a test object
If flat jet nozzles are used:
3.
Unscrew the threaded sleeve approx. 45°, so that the flat jet nozzle
(or its extension) can be moved slightly
4.
Turn the flat jet nozzle to desired axis direction