Faults
The following lists possible faults during operation and their clearance.
Fault
Cause
Corrective action
The gun does not
spray powder
although the
control unit is
switched on
Injector nozzle,
check valve unit,
powder hose or
powder gun are
clogged
Clean the
corresponding parts
and if necessary,
replace them
Gun achieving only
poor spray profile
Conveying vacuum
too low
Increase the powder
quantity and/or total
air volume on the
control unit
Cartridge worn,
clogged or not
inserted
Replace or install the
cartridge.