V
03/13
OptiFlex 2 B
Product description
•
13
Guide values for OptiFlex 2 CG09 with the
OptiFlow IG06 injector
All values in these tables are guide values. Differing environmental
conditions, wear and different powder types can affect the table values.
Total air
3 Nm³/h 4 Nm³/h 5 Nm³/h
Powder output (
g/min
)
Powder output
(%)
20
85 100 120
40
150 185 210
60
210 255 280
80
270 320 350
100
300 360 395
Air flow rates
The total air consists of conveying air and supplementary air, in relation
to the selected powder quantity (in %). As a result the total air volume is
maintained constant.
OptiFlex 2 B
Range
Factory
setting
Flow rate - fluidizing air
- OptiFlex B
0-1.0 Nm³/h
0.1 Nm³/h
Electrode rinsing air flow rate
0-3.0 Nm³/h
0.1 Nm³/h
Flow rate total air (at 5.5 bar)
1.8-6.5 Nm³/h
Note:
The total air consumption for the device is determined based on the
3 configured air values.
These values apply for an internal control pressure of 5.5 bar!
Electrical data
OptiFlex 2 B
Nominal input voltage
100-240 VAC
Frequency
50 -60 Hz
Connected load (without vibrator)
140 VA
Nominal output voltage (to the gun)
eff.10 V
Nominal output current (to the gun)
max. 1.2 A
Connection and output for vibrator (on Aux
output)
110/230 VAC
max. 100 W
Connection for rinsing function (valve)
24 VDC
max. 3 W
Temperature range
0°C - +40°C
(+32°F - +104°F)
Max. surface temperature
120 °C (+248 °F)
Approvals
II 3 D IP54 120 °C
Содержание OptiFlex 2 B
Страница 12: ......
Страница 22: ...V 03 13 20 Start up OptiFlex 2 B 3 4 5 6 7 8 9 10 Note The compressed air must be free of oil and water ...
Страница 32: ...V 03 13 30 Initial start up OptiFlex 2 B 24 25 26 27 28 29 30 31 32 33 34 ...
Страница 34: ......
Страница 38: ......
Страница 45: ...V 03 13 OptiFlex 2 B Spare parts list 43 ...