V
03/13
26
•
Initial start-up
OptiFlex 2 B
14. Coating
15. Adjust the coating parameters as necessary
16. Activate the rinsing function periodically
Note:
It prevents the bridging phenomena that can lead to short circuiting
when handling powders such as metallic powders.
In moist or tropical environments, any moisture is driven from the
injector, powder hose and powder gun.
a)
-
The LCD segments begin to move on the CG09 display
Note:
The PowerClean function can be stopped as required using the P
key.
b)
Procedure
Effect
automatic
- The automatic rinsing process is started
- Injector, powder hose, gun and spray nozzle are purged
using compressed air
- The automated PowerClean function enables parallel
cleaning of other components, such as the fluid intake
unit, powder container, etc.
manual
- The operator controls the number and length of the
PowerClean impulse by pressing the pistol trigger a
second time
After completion of the PowerClean procedure, the controller switches
back to coating mode.
= automatically
= manually
Содержание OptiFlex 2 B
Страница 12: ......
Страница 22: ...V 03 13 20 Start up OptiFlex 2 B 3 4 5 6 7 8 9 10 Note The compressed air must be free of oil and water ...
Страница 32: ...V 03 13 30 Initial start up OptiFlex 2 B 24 25 26 27 28 29 30 31 32 33 34 ...
Страница 34: ......
Страница 38: ......
Страница 45: ...V 03 13 OptiFlex 2 B Spare parts list 43 ...