
Rev. 00 08/17
54
Fault clearance
MultiStar CG10
Code
Description
Criteria
Remedy
H67
Supplementary air
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H68
Electrode rinsing air
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
Gun Controller
190
Communication error
MU
Disruption or damage to the
connection between the
additional panel print board and
Gun Controller, invalid command
parameter, command is not
supported. etc.
Contact a Gema service
center
290
Communication error
AU
194
Firmware Update
necessary MU
The Gun Controller firmware is
not up-to-date.
Update, contact Gema
service
294
Firmware Update
necessary AU
192
Gun Controller MU
does not react
No connection can be made with
the Gun Controller.
Reason: Additional device
connected, but not activated.
Contact a Gema service
center
292
Gun Controller AU
does not react
Help codes list
The last appeared eight errors are stored in a list by the software. If an
error appears, which is already in the list, he will not be listed again.
Appearance of errors
It is possible that an error is only displayed for a short time, but after the
acknowledgement it will disappear. In this case, it's recommended to
switch off the control unit and switch it on again (reset by restarting).
Содержание MultiStar CG10
Страница 6: ......
Страница 24: ...Rev 00 08 17 24 Product description MultiStar CG10 ...
Страница 50: ...Rev 00 08 17 50 Maintenance Repairs MultiStar CG10 ...
Страница 56: ...Rev 00 08 17 56 Disposal MultiStar CG10 ...
Страница 62: ......
Страница 64: ...Rev 00 ...