Rev. 00 08/17
MultiStar CG10
Fault clearance
53
Code
Description
Criteria
Remedy
H27
EEPROM verification
erroneous
EEPROM error
Contact a Gema service
center
CAN bus:
H40
Permanent CAN bus
error
The CAN controller changes into
BUS OFF condition.
No power supply or cable is not
connected.
Connect the cable,
otherwise contact Gema
service
H41
High error rate when
transmitting/receiving
The CAN controller changes into
ERROR_PASSIVE condition
Contact a Gema service
center
H42
Overflow on data
reception
The message to be received has
no more place in the receiver
buffer. Messages are sent faster
than they can be processed.
Contact a Gema service
center
H43
Overflow on
transmission
The message to be sent has no
more place in the transmission
buffer. Messages are produced
faster than they can be sent.
Contact a Gema service
center
H44
Master failed
Node Guarding message is
missing longer than 2 seconds.
Connection to master failed.
Check the connection to the
Master, otherwise contact
Gema service
H45
Parameter value
outside the value
range
The sent parameter value is
outside the allowed value range
Check input values
H46
Invalid Node ID set
The Node ID is not between 1
and 127
Set Node ID to 127
H47
No CAN interface
installed
CAN interface is selected in the
system parameters, but no
interface is installed
Contact a Gema service
center
H48
No ACK to "Boot Up
Message" received
No CAN node is answering to the
"Boot Up Message".
Check cabling connections
between the users,
otherwise contact Gema
service
Throttle motors:
H60
Conveying air
reference position not
found
Throttle motor or needle jammed,
limit switch defective, error in
motor throttle
Contact a Gema service
center
H61
Supplementary air
reference position not
found
Throttle motor or needle jammed,
limit switch defective, error in
motor throttle
Contact a Gema service
center
H62
Electrode rinsing air
reference position not
found
Throttle motor or needle jammed,
limit switch defective, error in
motor throttle
Contact a Gema service
center
H63
Conveying air throttle
does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H64
Supplementary air
throttle does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H65
Electrode rinsing air
throttle does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H66
Conveying air position
lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center