Rev. 00 08/17
MultiStar CG10
Start-up
33
Hardware
The MultiStar control units are connected to the central PLC control unit
via 4 pin CAN bus cables. The last bus client is fitted with a terminal plug
with terminal resistor in order to terminate the network correctly. A
maximum of up to 127 MultiStar Control units can be operated in a
network.
MultiStar no. 1
MultiStar no. 2
CAN-Bus
participant
no. 127 (max)
fig. 19: CAN bus
– connections
1
PLC control with CAN bus
2
Terminal resistor
CAN bus cable
– plug assignment
fig. 20: CAN bus cable
Pin
Signal
Color
1
GND
white
2
+24 VDC
black
3
CAN H
black
4
CAN L
black