Rev. 03 05/20
OptiStar 4.0 (CG21)
Fault clearance
59
Code
Description
Criteria
Remedy
H61
Supplementary air
reference position not
found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H62
Electrode rinsing air
reference position not
found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H63
Fluidizing air reference
position not found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H64
Conveying air throttle
does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H65
Supplementary air throttle
does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H66
Electrode rinsing air
throttle does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H67
Fluidizing air throttle does
not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H68
Conveying air position
lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H69
Supplementary air
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H70
Electrode rinsing air
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H71
Fluidizing air position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
Communication mainboard-gun:
H91
Communication error
mainboard-gun
Gun not connected
Gun, gun cable or Mainboard
defective
connect
Replace or contact Gema
Service
Help codes list
The last appeared four errors are stored in a list by the software. If an
error appears, which is already in the list, he will not be listed again.
Appearance of errors
It is possible that an error is only displayed for a short time, but after the
acknowledgement it will disappear. In this case, it's recommended to
switch off the control unit and switch it on again (reset by restarting).
Содержание GG21
Страница 6: ......
Страница 40: ...Rev 03 05 20 40 Start up OptiStar 4 0 CG21 ...
Страница 52: ...Rev 03 05 20 52 Operation OptiStar 4 0 CG21 ...
Страница 56: ...Rev 03 05 20 56 Maintenance Repairs OptiStar 4 0 CG21 ...
Страница 60: ...Rev 03 05 20 60 Fault clearance OptiStar 4 0 CG21 ...
Страница 62: ...Rev 03 05 20 62 Disposal OptiStar 4 0 CG21 ...
Страница 67: ...Rev 03 05 20 OptiStar 4 0 CG21 Spare parts list 67 Inside back plate fig 26 OptiStar CG21 ...
Страница 69: ...Rev 03 05 20 OptiStar 4 0 CG21 Spare parts list 69 Connecting material fig 27 ...
Страница 70: ......
Страница 72: ...Rev 03 05 20 72 Index OptiStar 4 0 CG21 ...
Страница 73: ......
Страница 74: ...Rev 03 ...