Rev. 03 05/20
48
Operation
OptiStar 4.0 (CG21)
Procedure
Effect
Automatic
(automatic)
– The rinsing process is started
– Injector, powder hose, gun and spray nozzle
are purged using compressed air
– The PowerClean function enables parallel
cleaning of other components, such as the
fluid intake unit, powder container, etc.
– The rinsing mode is exited if the automatic
rinsing sequence has finished.
Manual
(manual)
The operator controls the number and length of the
PowerClean impulse by pressing the gun trigger a
second time
4.
STOP =
OR
OR the cleaning mode is terminated automatically.
After completion of the PowerClean procedure, the controller switches
back to coating mode.
Manual equipment with optional PowerClean module
(system parameter P01= 1 or P01=2)
The rinsing mode can only be activated from standby mode (main menu
display, no powder conveying).
1.
OR
2.
START =