
Rev. 03 05/20
OptiStar 4.0 (CG21)
Operation
41
Operation
Operation
During the initial commissioning of the device, the functional
check is to be performed without powder!
Select predefined operating mode (Preset mode)
1.
Turn on the gun control unit with the
ON
key
2.
Press the corresponding application key.
The arrow above the desired button lights up.
The pre-defined application modes have preset values for high
voltage and spray current:
Application mode
Preset kV
Preset µA
flat parts
100
100
complicated parts
100
22
overcoat
100
10
3.
The air values for total air, powder output and electrode rinsing air
can be individually defined and are saved in the programs.
Содержание GG21
Страница 6: ......
Страница 40: ...Rev 03 05 20 40 Start up OptiStar 4 0 CG21 ...
Страница 52: ...Rev 03 05 20 52 Operation OptiStar 4 0 CG21 ...
Страница 56: ...Rev 03 05 20 56 Maintenance Repairs OptiStar 4 0 CG21 ...
Страница 60: ...Rev 03 05 20 60 Fault clearance OptiStar 4 0 CG21 ...
Страница 62: ...Rev 03 05 20 62 Disposal OptiStar 4 0 CG21 ...
Страница 67: ...Rev 03 05 20 OptiStar 4 0 CG21 Spare parts list 67 Inside back plate fig 26 OptiStar CG21 ...
Страница 69: ...Rev 03 05 20 OptiStar 4 0 CG21 Spare parts list 69 Connecting material fig 27 ...
Страница 70: ......
Страница 72: ...Rev 03 05 20 72 Index OptiStar 4 0 CG21 ...
Страница 73: ......
Страница 74: ...Rev 03 ...