Page 38
Société des Anciens Établissements L.GEISMAR
– Prohibited Reproduction ©
– Connect the brakes to the hydraulic system.
Specifications:
• Closed braking system
• Min. pressure: 55 bar
• Max. pressure: 100 bar
• Flow rate: 10 l/min
• DN10 hose
7 – 2
Verification procedure
– When the cylinder is depressurised, measure the distance between the outer surface of the
washer and base of the shoe. This must measure 67 mm. If not, carry out the brake adjust-
ment procedure (see 7.3).
– If once the cylinder is depressurised the brake shoe is up against the bottom of the slot, this
indicates maximum wear (see 7.4).
7 – 3
Brake adjustment
A system is provided to check whether a brake adjustment is needed. The position of the pins
(framed in red) shows how much the brakes are worn.
POSITION BEFORE WEAR
Содержание BRV
Страница 2: ......
Страница 6: ......
Страница 17: ...Page 17 Société des Anciens Établissements L GEISMAR Prohibited Reproduction 3 2 Dimensions ...
Страница 22: ......
Страница 36: ......
Страница 42: ......
Страница 44: ......
Страница 46: ......
Страница 48: ......
Страница 49: ...Section A Mechanical Components ...
Страница 51: ......
Страница 53: ......
Страница 55: ......
Страница 57: ......
Страница 59: ......
Страница 61: ......
Страница 63: ......
Страница 65: ......
Страница 67: ......
Страница 69: ......
Страница 70: ......
Страница 71: ...Section B Hydraulic Components ...
Страница 73: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......
Страница 79: ......
Страница 81: ......
Страница 83: ......
Страница 84: ......
Страница 85: ...Optional Components ...
Страница 87: ......
Страница 89: ......
Страница 91: ......
Страница 93: ......
Страница 94: ......