Alarm states can be configured in probe fault
condition

Triac output

20...240Vac ±10%, 2Amax, load I

2

t = 128A

2

s

Cycle time

0...200 sec

Type of main output

relay, logic

Control outputs

on / off, pwm

Limitation Max power heat / cool

0,0...100,0 %

Linear scale ranges

-1999 to 9999 configurable decimal point position

Control actions

Pid, Autotune, on-off

pb

0,0...999,9 %

dt

0,00...99,99 min

di

0,00...99,99 min

Action

heat or cool

Softstart

0,0...500,0 min

Configurable alarms

Up to 3 alarm functions assignable to an output
and configurable as: maximum, minimum,
symmetrical, absolute/relative, LBA

Fault power setting

-100,0...100,0 %

Software turn-off function

Can be excluded

Alarm masking

exclude on power-up

Max. RTD line resistance

20

Safety

detection of short circuit or opening of probes, LBA
alarm

RTD type (scale configurable within
indicated range, with or without decimal point)

DIN 43760 (Pt100)

Cold junction error

0,1° / °C

PTC type (on request)

990

, 25°C

Thermocouples

IEC 584-1 (J, K, R, S, T, B, E, N)

Main input

TC, RTD (Pt100), PTC
60mV, Ri 

500K; 20mA, Ri = 50

; 10V Ri < 20K

For correct and safe
installation, follow the
instructions and observe
the warnings contained in
this manual.

Faceplate protection

IP65

Working / Storage temperatures

0 to 50°C / -20 to 70°C

Relative humidity

20 to 85%, non-condensing

Installation

Panel mounting

Weight

110g for the complete version

°C / °F selection

Faceplate configurable

Relay contact

NO (NC) 5A, 250V

Logic output for static relays

power supply > 18Vac/dc,
Rout = 560

(6Vmin / 20mA)

Fault settings

2-wire Transmitter Power Supply
(option)

18V ±10% 50mA
1.2V for potentiometer > 100 

(version P77)

Power supply
(not isolated from sensor input)

11...27Vdc, 18...27Vac ±10%, 50/60Hz, 4,5VA

Display

4 digit red LED’s, digit height 14mm

Keys

3 mechanical keys (Raise, Lower, F)

Accuracy

0.2% f.s. at 25°C ambient temperature

76

72

36

30

69,5

43

83

52

9,5

1 • INSTALLATION

• Dimensions and cut-out: Panel mounting

Panel mounting:

Fix the device with the bracket provided before making any electrical connections.
To mount two or more devices side by side, use the cut-out dimensions shown above.

CE MARKINGEMC (electromagnetic compatibility) conformity to EEC Directive
89/336/CEE with reference to the generic Standard EN61000-6-2 (immunity in
industrial environments) and EN50081-1 (emission in residential environments).
BT (low voltage) conformity to Directive 73/23/CEE as modified by Directive 93/68.
MAINTENANCERepairs must be done out only by trained and specialized personnel.
Cut power to the device before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene, etc.).
Use of these solvents can reduce the mechanical reliability of the device. Use a cloth
dampened in ethyl alcohol or water to clean the external plastic case.
SERVICEGEFRAN has a service department. The warranty excludes defects caused
by any use not conforming to these instructions.

2 • TECHNICAL SPECIFICATIONS

FUNCTION

CABLE

LENGTH USED

TC input probe

0,8 mm

2

compensated 5 

mt

“PT100” input probe

1 mm

2

3 mt

Power supply cable

1 mm

2

1 mt

Relay output cables

1 mm

2

3,5 mt

EMC conformity has been tested with the following connections

!

10

40T 72 PID

UNIVERSAL SINGLE DISPLAY HEAT CONTROL

SOFTWARE VERSION 1.0x 
code 81761A / edition 05 06/04

USER’S MANUAL

Содержание 40T 72 PID

Страница 1: ...pply option 18V 10 50mA 1 2V for potentiometer 100 Ω version P77 Power supply not isolated from sensor input 11 27Vdc 18 27Vac 10 50 60Hz 4 5VA Display 4 digit red LED s digit height 14mm Keys 3 mechanical keys Raise Lower F Accuracy 0 2 f s at 25 C ambient temperature 76 72 36 30 69 5 43 83 52 9 5 1 INSTALLATION Dimensions and cut out Panel mounting Panel mounting Fix the device with the bracket ...

Страница 2: ...IPTION OF FACEPLATE Function key Gives access to different configuration stages Confirms any parameter changes Standard 18 to 27 Vac 11 to 27Vdc 10 50 60 Hz 4 5 VA max not isolated from sensor input Linear Input V Outputs Pt100 PTC NTC 3 1 2 2 1 Linear Input I 4 1 2 10 8 9 7 Out1 Out2 Power supply 11 12 Outputs TC 2 1 4 2 3 1 Ri 50Ω 4 20mA Linear input with 2 wire transmitter PWR PV display Indica...

Страница 3: ...u 5 Standard Configuration Menu Enable selftuning autotuning softstart Proportional band for heating or hysteresis in regulation ON OFF Integral heating time Derived heating time Maximum limit heating power S tu Autotuning Selftuning Softstart continuous 0 NO NO NO 1 YES NO NO 2 NO YES NO 3 YES YES NO 4 NO NO YES 0 999 9 f s 0 00 99 99 min 0 00 99 99 min 0 0 100 0 0 10 0 4 0 1 0 100 0 Default Cust...

Страница 4: ...min Reset power 100 0 100 0 999 scale points Hysteresis for alarm 2 Hysteresis for alarm 1 999 scale points Hysteresis for alarm 3 Integral cooling time 0 00 99 99 min Derived cooling time 0 00 99 99 min Manual reset 999 999 scale points Maximum limit cooling power 0 0 100 0 N B the LBA alarm is excluded for ON OFF controls 13 6 PROGRAMMING and CONFIGURATION F If the Inc Dec F keys are not pressed...

Страница 5: ...YP Signal type Scale Max scale range 24 0 10V linear 1999 9999 25 2 10V linear 1999 9999 SENSOR VOLTAGE 10V or TRANSMITTER CAL 6 InP Input settings Digital filter on main input Digital filter on display of process variable acts as hysteresis Decimal point position for main input scale not available for TC RTD PTC scales Minimum limit of main input scale Maximum limit of main input scale Main input...

Страница 6: ...ycle time OUT3 relay or logic HEAT or COOL 0 200 sec Prot Pro Protection code Pro Display Change 0 SP alarms OutP SP alarms 1 SP alarms OutP SP 2 SP SP 3 SP 4 disable InP Out 8 disable CFG 16 disable SW turn on turn off To activate the turn off SW function press keys F for 5 secs in P V To return to normal functioning press key F for 5 secs 15 OUT 1 Attribution of reference signal HEAT COOL AL1 AL...

Страница 7: ...by means of the TRAFO1 transformers specified in the manual one for each device when The application is unknown Multiple devices have input signals that are not isolated from one another such as for example non isolated grounded thermocouples transducers or transmitters powered by a single supply linear inputs with voltage or current not isolated from one another It is a general rule that devices ...

Страница 8: ... remote switches contactors relays thyristor power units particularly if phase angle type motors etc in the same cabinet avoid dust humidity corrosive gases and heat sources do not close the ventilation holes working temperature must be in the range of 0 50 C If the device has faston terminals they must be protected and isolated if the device has screw terminals wires should be attached at least i...