RS-232 / TELNET / UDP COMMANDS
#set_input_name Command
The #set_input_name command provides a name to the selected input. For example,
“Input 1” could be renamed as “Computer 1”. The maximum string length for
param2
is
15 characters. Special characters and spaces are not permitted. If required, use the
underscore character (“_”) to separate characters.
Syntax:
#set_input_name param1 param2
Parameters:
param1
Input
[1
...
16]
param2
Name
Example:
#set_input_name 5 computer1
computer1 is assigned to input 5
#set_ir Command
The #set_ir set the IR channel for the matrix. The associated DIP switch settings for the IR
remote control unit are returned. See page 9 for details on setting the IR channel for the IR
remote control.
Syntax:
#set_ir param1
Parameters:
param1
Channel
[0
...
3]
Example:
#set_ir 2
RMT_IR - SW1=0,SW2=1