Warranty 

 

Dropmaster  warrants  to  the  original  purchaser  thereof  (the  “Original  Purchaser”)  that  the 
Dropmaster  and  parts  thereof  furnished  by  GECCO,  Inc.  –  (“GECCO”)  will,  when  properly 
installed,  used  operated  and  maintained  by  the  Original  Purchaser,  be  free  from  defects  in 
material  and  workmanship  for  a  period  of 

Ninety  (90)  Days 

from  the  date  of  delivery  to  the 

Original  Purchaser.    Any  Dropmaster  that  is  found  not  to  meet  these  standards  by  GECCO 
within  this  ninety-day  period  will,  at  GECCO’s  sole  option,  be  repaired  or  replaced  without 
charge.    Any  defect  or  condition  that  has  been  caused  by  misuse,  unauthorized  use  or 
modification, or abnormal conditions of operation or maintenance, will be repaired by GECCO 
or  its designee  at  GECCO’s  then  current  repair  charges.    In this  case,  upon  the  request of  the 
Original Purchaser, GECCO will submit an estimate of the repair cost to the purchaser prior to 
making  the  repairs.    Any  defective  Dropmaster  or  component  thereof  should  be  returned 
promptly to GECCO at the sole expense of the Original Purchaser.  Any loss or damage during 
shipment of a defective Dropmaster or component thereof shall be at the Original Purchaser’s 
sole risk. 
 

The  motor  and  compressor  are  warranted  One  Year  (1)  from  the  date  of  delivery  from  the 
manufacturer. 

Owner responsibility includes providing normal maintenance as required by Gecco, 
Inc. This warranty does not apply (1) if the pump(s) has been damaged due to 
improper use, neglect, accident, misuse, and exposure to extremities of dryness or 
humidity (2) if pump(s) has been serviced or modified by other than Gecco, Inc. 
authorized personnel. 
 

No other warranty expressed or implied is given. The repair or replacement of 

the pump(s) is your exclusive remedy. Any implied warranty of merchantability or 
fitness is limited to the declaration of this written warranty. In no event shall Gecco, 
Inc. be liable for consequential or incidental damages. Some states do not allow the 
exclusion or limitation of this warranty so the above exclusions or limitations may 
not apply to you. This warranty gives you specific legal rights and you may have 
other rights, which vary, from state to state. 
 

Discharge water pump has a ninety (90) day warranty.  

 

This warranty does not cover product failure resulting from: 

 

 

1. Normal wear. 
2. User abuse, including immersing non-submersible products, dents or     
damage to barrel 

 

 
 
 

-9- 

 

Содержание Dropmaster DM12

Страница 1: ...OPERATION MANUAL...

Страница 2: ...ntents I Introduction page 2 II Safety Instructions page 3 III Operations Procedures page 4 IV Water Calculations Sheet page 5 V Troubleshooting page 6 VI Maintenance page 7 VII Model Information opti...

Страница 3: ...rom Gecco Inc The Dropmaster DM12 has several safety features you should be aware of The 3 4 horsepower high torque low amp motor has manual thermal overload protection Additionally each unit is suppl...

Страница 4: ...n contact with these components 7 Do not touch moving parts while the Dropmaster is in service 8 Technician operating the Dropmaster should utilize eye and hearing protection at all times 9 Unit shoul...

Страница 5: ...will be connected to 5 Connect the suction side of the Dropmaster with suction valve closed to your choice of outlet and connect the discharge hose to a suitable drain 6 Turn unit on and open suction...

Страница 6: ...ng Dropmaster in service 1 Gallon of water 8 344 lbs Pressure Vacuum 1 psi 2 036 inches H G 5 psi 10 18 inches H G 10 psi 20 36 inches H G 15 psi 30 54 inches H G Water in Pipes By Size Pipe Size Sche...

Страница 7: ...ring and barrel lid 3 IF LOW OR NO VACUUM AT END OF SUCTION HOSE Clean out 1 wye strainer remove 3 8 plug and then remove large bushing and pull out strainer basket Check for any blockages 4 IF GUAGE...

Страница 8: ...h and clean storage tank after daily use Unit should be stored indoors in a clean dry location Check and clean strainer Remove the strainer basket and it is free of debris or sludge Replace the basket...

Страница 9: ...ter DM12 Features Deisgned and built for 24 7 operation all of the Dropmaster s components are rated for continuous duty Powered by a hp high torque low amp motor 1 3 hp discharge pump capable of pump...

Страница 10: ...ent of a defective Dropmaster or component thereof shall be at the Original Purchaser s sole risk The motor and compressor are warranted One Year 1 from the date of delivery from the manufacturer Owne...

Страница 11: ...essly authorized in writing by GECCO LIMITATION OF LIABILITY To the extent allowable under law GECCO s liability for consequential and incidental damages is expressly disclaimed GECCO s liability in a...

Страница 12: ...Maintenance Manual For Vapor Oil Pumps Model DM12 IMPORTANT READ BEFORE INSTALLATION OF THIS UNIT 11...

Страница 13: ...or low voltage service VAPOR OIL PUMPS Use a 10W 30 Oil for all Conde Vapor Oil Pumps When starting new vapor oil pumps fill oil reservoir above the fittings in which the wicks are inserted This will...

Страница 14: ...cted away from the motor Be careful to contain any mist or spray 3 Use kerosene or diesel fuel fluid for flushing process While the pump is running under vacuum simply insert the tube into the cleanin...

Страница 15: ...14...

Страница 16: ...pump The pump must be assembled in the same position This will align the rotor with the endplates and housing 4 Install the slinger over shaft green disk 5 Press bearing on the shaft using a bearing i...

Страница 17: ...16...

Отзывы: