For additional technical assistance, call 800/TEC-TRUE (800-832-8783) or visit our website at chicagofaucets.com.
2
HyTronic
®
User Guide Installation Instructions
(continued)
Mounting of Lavatory and Gooseneck Faucet
Prerequisites
• Supply valve is installed
• Water supply lines are flushed properly
• For AC and faucets with EBPS, power outlet is installed
Important
• It is not necessary to unscrew the connection between braided hose and housing
to install the product.
• Do not remove protective covering from sensor until starting up faucet operation.
• Do not tighten locknut before step 4 is completed.
1. Mount cover plate if
required. Plumber’s putty is
recommended to seal cover
plate to the sink. Security pin
must be located on the left side.
2. Mount gasket and put faucet
into sink.
3. Mount bracket from underneath.
Place hoses through large
opening and mounting rod
through small opening. Make
sure flange sits securely against
surface.
4. Place nut onto mounting rod
and tighten with wrench.
5. If faucet was installed with cover
plate, secure with basin washer,
flat washer and locknut.
6. Install aerator and tighten with
aerator key (supplied).
7. For Gooseneck faucets, tighten
spout with wrench.
8. Connect braided hose with filter
to supply valve.
Cold water > white label
Hot water > no label
Note: For AC faucets and faucets
with EBPS, please refer to the
plugin or hardwired transformer
installation instructions.
9. Connect to power supply.
The faucet is now mounted.
Mounting of Wall Mount Faucet
Prerequisites
• Supply valve is installed
• Water supply lines are flushed properly
• For AC faucets and faucets with EBPS power outlet is installed
Important
• It is not necessary to unscrew the connection between braided hose and
housing to install the product.
• Do not remove protective covering from sensor until starting up faucet operation.
1. Mount gasket, put faucet into
opening and tighten
2. Install aerator and tighten with
aerator key (supplied)
3. For gooseneck faucets, tighten
spout with wrench
4. Connect braided hose with filter
to supply valve
Cold water > white label
Hot water > no label
For AC faucets and faucets with EBPS,
please refer to the plugin or hardwired
transformer installation instructions.
5. Connect to power supply
The Wall Mount faucet is now
mounted.