Pre-operation checks should be made each time you 

need to operate

The engine and muffler will be very hot after the 

engine has been run. Avoid touching the engine and 

muffler while they are still hot with any part of your 

body or clothing during inspection or repair.

FUEL

•  Fuel is highly flammable and poisonous. Check 

“SAFETY INFORMATION” (See page 2-5) carefully 

before filling. 

•  Do not overfill the fuel tank, otherwise it may 

overflow when the fuel warms up and expands. 

•  After fill the fuel, make sure the fuel tank cap is 

tightened securely. Immediately wipe off spilled 

fuel with a clean. Use only unleaded gasoline. The 

use of leaded gasoline will cause severe damage to 

the internal engine parts. 

Remove the fuel tank cap 

1. Fill to the red mark

2. Upper level when refuelling

Recommended fuel:

Unleaded gasoline (95 octan) –  

Tank capacity: 4,0 liter

TIP: Gasoline will deteriorate after time, and old 

gasoline might cause startup problems. Make sure to 

use fresh gasoline. 

ENGINE OIL

The generator has been shipped without engine oil. 

Do not start the engine until filled with the sufficient 

engine oil. Do not tilt the generator when adding 

engine. This could result in overfilling and damage to 

the engine. 

1. Place the generator on a level surface.

2. Remove the screws (2), and then remove the 

cover (3). 

3. Remove the oil filler cap (1). 

4. Fill with the specified amount of the recommended 

engine oil, and then install and tighten the oil filler 

cap.

5. Install the cover and tighten the screws.

RECOMMENDED ENGINE OIL

Engine oil

SAE 10W -30

Engine oil grade

API Service SE type, or 

higher quality.

Engine oil quantity 0,6 liter

CHECKLIST BEFORE USE

a) FUEL  (read page 27)

•  Check fuel level

•  Refill if needed

b) ENGINE OIL  (read page 27)

•  Check engine oil level

•  If level is too low, please refill with recommended 

oil until specified level

•  Check if any oil leackages

Never operate the engine in a closed area or it may 

cause unconsciousness and death within a short 

time. Operate the engine in a well ventilated area. 

Before starting the engine, do not connect any 

electric devices.

Always check the condition of the generator before 

use. The generator has been shipped without engine 

oil. Do not start the engine till fill with the sufficient 

engine oil. 

ATMOSPHERIC CONDITIONS

The generator can be used with the rated output load 

at standard atmospheric conditions.

“Standard atmospheric conditions ”; Ambient 

temperature 25°C. Barometric pressure 100kPa; 

Relative humidity 30% The output of the generator 

varies due to change temperature, altitude (lower air 

Содержание Powerman 3000i

Страница 1: ...POWERMAN 3000i ART NR 570817 MANUAL...

Страница 2: ...boken og varsel symboler p aggregatet ikke dekke alle farlige forhold Hvis vi ikke gir ekstra forsiktighetsregler for operasjonsprosedyrer metoder eller teknikker betjen generatoren p en slik m te at...

Страница 3: ...r m te Hvis generatoren skal kobles til str mnettet hjemme som en standby skal tilkoblingen utf res av en profesjonell elektriker N r lasten er koblet til generator m du sjekke n ye om elektriske kobl...

Страница 4: ...iske enheter fra aggregatet f r vedlikeholdsarbeid utf res f r du forlater enheten og etter at den er sl tt av En advarsel minner brukeren p at han skal overholde forskrifter for elektrisk sikkerhet s...

Страница 5: ...lyse r dt dersom det tilkobles og brukes utstyr som krever mer str m enn aggregatet produserer om inverter overopphetes eller om spenningen ker For hindre skade p aggregatet og tilkoblet utstyr vil b...

Страница 6: ...rever h y startstr m TANKLOKK 1 Skru av tanklokket ved dreie det mot urviserne 2 Tanklokket 2 er utrustet med vrider 1 for pne og lukke ventilasjonen av bensintanken Vrideren m settes i posisjon ON pe...

Страница 7: ...t underlag 2 Skru ut skruene 1 ta av sidepanel 2 3 Skru ut oljep fyllingslokket 3 4 Fyll motorolje i henhold til spesifikasjonene Fyll til vre gjenge i p fyllingshullet Skru deretter tilbake oljep fyl...

Страница 8: ...dtaket n r du drar i startsnoren Slipp ikke startsnoren hurtig tilbake F r den forsiktig tilbake for unng skade p startappratet 5 N r motoren har startet vri motorbryteren til posisjon ON DRIFT 4 TIPS...

Страница 9: ...manual for batteriet Automatsikringen vil l se ut ved overbelastning av DC kursen dersom batteriet trekker for mye ladestr m eller om det er foretatt en feilkopling Dersom dette oppst r vent noen min...

Страница 10: ...pling av sensitivt utstyr som PC TV lesebrett datamaskiner elektroniske m leinstrumenter eller elektroniske batteriladere s rg for holde avstand til str maggregatet for unng elektrisk forstyrrelser fr...

Страница 11: ...ller tilstand Rengj r og skift dersom n dvendig Bensinfilter Rengj r og skift dersom n dvendig Slange for veivhusventilasjon Kontroller slange for sprekkdannelser eller annen skade Skift ved behov Top...

Страница 12: ...torens oljekvalitet er en avgj rende faktor for motorens ytelse og levetid Bruk kun anbefalt motorolje 3mguWSUa 1 Plasser str maggregatet p et horisontalt niv ved kontroll av oljeniv Ved oljeskift sta...

Страница 13: ...ospotte blir ekstremt varme n r str maggregatet er i drift La aggregatet kj les ned f r vedlikehold igangsettes 1 Skru ut skruene 1 og ta av gitterlokket 2 2 L sne bolten 3 ta bort lokket 4 ytre gnist...

Страница 14: ...ing Bensin er ferskvare Gammel bensin kan for rsake startproblemer Dette forsterkes ved start om vinteren ved lav temperatur Ved lagring over tid anbefales at bensintank og forgasser t mmes for bensin...

Страница 15: ...omatsikring for DC 12V i pos OFF AV Trykk den inn til pos ON P Driftslampen for 230V gr nn slukker Stopp motoren og start p nytt TEKNISKE DATA Modell PM3000i GENERATOR Generator type Inverter Frekvens...

Страница 16: ...16 Norsk KOBLINGSSKJEMA Standardmodell 230V 50Hz...

Страница 17: ...Bruk av PM3000i som er parallellkoplet Ved benytte spesialkablene tilleggsutstyr se bilde 1 artnr 573338 kan 2 stk PM3000i parallell koples for ke avgitt effekt F lg instruksjonene for sammenkopling...

Страница 18: ...is reason warnings in this manual and caution signs on the generator may not cover all hazardous circumstances If we do not give extra cautions for operating procedures methods or techniques operate t...

Страница 19: ...Use the ground wire with enough electric flux If the generator is to be connected to a home power supply as a standby connection shall be performed by a professional electrician or by another person w...

Страница 20: ...rming maintenance works before leaving the device and after switching it off A warning reminding the user that he shall conform to regulations of electrical safety applicable to the place where the ge...

Страница 21: ...erload indicator light 1 comes on when an overload of a connected electrical device is detected the inverter control unit overheats or the AC output voltage rises Then the AC protector will trip stopp...

Страница 22: ...00r min Regard less of whether is load connected or not Tip The ESC must not be turned to OFF when using electric devices that require a large starting current such as a compressor of a submergible pu...

Страница 23: ...ld result in overfilling and damage to the engine 1 Place the generator on a level surface 2 Remove the screws 2 and then remove the cover 3 3 Remove the oil filler cap 1 4 Fill with the specified amo...

Страница 24: ...turned to the ON position 4 TIP When starting the engine with the ESC ON and there is no load on the generator In ambient temperature below 0 C the engine will run at the rated 5000r min for 5 minutes...

Страница 25: ...bances Charge the battery in the correct procedure by following instructions in the owner s manual for the battery The DC protector turns off automatically if current above the rated flows during batt...

Страница 26: ...ference from the engine Also ensure that electrical noise from the engine does not interfere with any other electrical devices located near the generator If the generator is to supply medical equipmen...

Страница 27: ...d replace if necessary Fuel filter Clean and replace if necessary Crankcase breather hose Check hose weather for cracks or damage Replace if necessary Cylinder head Decarbonizes cylinder head more fre...

Страница 28: ...sional knowledge specialized date and equipment to do so properly ENGINE OIL REPLACEMENT Avoid draining the engine oil immediately after stopping the engine The oil is hot and should be handled with c...

Страница 29: ...hile they are still hot with any part of your body or clothing during inspection or repair 1 Remove the screws 1 and then pull outward on the areas of the cover 2 shown 2 Loosen the bolt 3 and then re...

Страница 30: ...ngine depends on the amount of the fuel left in the tank Fuel is highly flammable and poisonous Check SAFETY INFORMATION Immediately wipe off spilled fuel with a clean dry soft cloth since fuel may de...

Страница 31: ...ight green go off Stop the engine and then restart PARAMETERS Model PM3000i GENERATOR Generator type Inverter Rated frequency 50 Hz Rated voltage 230V Max output power 2 5 kW Rated output power 2 3 kW...

Страница 32: ...32 English ELECTRICAL SCHEMATIC DIAGRAM 50Hz 230V Without Parallel Receptacle...

Страница 33: ...Always remove cable if only using one generator How to use PM3000i in parallel operation By using the cable kit optional see picture 1 artno 573338 you can connect 2 pcs PM3000i in parallel operation...

Страница 34: ...34...

Страница 35: ...35...

Страница 36: ...er i samsvar med f lgende direktiver og standarder Intygar att denna produkt verensst mmer med kraven i f ljande direktiv och standarder Product Inverter generator Str maggregat Elverk Model Gebe 570...

Отзывы: