23
English
PRE-OPERATION
Pre-operation checks should be made each time you
need to operate
The engine and muffler will be very hot after the
engine has been run. Avoid touching the engine and
muffler while they are still hot with any part of your
body or clothing during inspection or repair.
FUEL
• Fuel is highly flammable and poisonous. Check
“SAFETY INFORMATION” (See page 2-5) carefully
before filling.
• Do not overfill the fuel tank, otherwise it may
overflow when the fuel warms up and expands.
• After fill the fuel, make sure the fuel tank cap is
tightened securely. Immediately wipe off spilled
fuel with a clean. Use only unleaded gasoline. The
use of leaded gasoline will cause severe damage to
the internal engine parts.
Remove the fuel tank cap
1. Fill to the red mark
2. Upper level when refuelling
Recommended fuel:
Unleaded gasoline (95 octan) –
Tank capacity: 4,0 liter
TIP: Gasoline will deteriorate after time, and old
gasoline might cause startup problems. Make sure to
use fresh gasoline.
ENGINE OIL
The generator has been shipped without engine oil.
Do not start the engine until filled with the sufficient
engine oil. Do not tilt the generator when adding
engine. This could result in overfilling and damage to
the engine.
1. Place the generator on a level surface.
2. Remove the screws (2), and then remove the
cover (3).
3. Remove the oil filler cap (1).
4. Fill with the specified amount of the recommended
engine oil, and then install and tighten the oil filler
cap.
5. Install the cover and tighten the screws.
RECOMMENDED ENGINE OIL
Engine oil
SAE 10W -30
Engine oil grade
API Service SE type, or
higher quality.
Engine oil quantity 0,6 liter
CHECKLIST BEFORE USE
a) FUEL (read page 27)
• Check fuel level
• Refill if needed
b) ENGINE OIL (read page 27)
• Check engine oil level
• If level is too low, please refill with recommended
oil until specified level
• Check if any oil leackages
Never operate the engine in a closed area or it may
cause unconsciousness and death within a short
time. Operate the engine in a well ventilated area.
Before starting the engine, do not connect any
electric devices.
Always check the condition of the generator before
use. The generator has been shipped without engine
oil. Do not start the engine till fill with the sufficient
engine oil.
ATMOSPHERIC CONDITIONS
The generator can be used with the rated output load
at standard atmospheric conditions.
“Standard atmospheric conditions ”; Ambient
temperature 25°C. Barometric pressure 100kPa;
Relative humidity 30% The output of the generator
varies due to change temperature, altitude (lower air
Содержание Powerman 3000i
Страница 1: ...POWERMAN 3000i ART NR 570817 MANUAL...
Страница 16: ...16 Norsk KOBLINGSSKJEMA Standardmodell 230V 50Hz...
Страница 32: ...32 English ELECTRICAL SCHEMATIC DIAGRAM 50Hz 230V Without Parallel Receptacle...
Страница 34: ...34...
Страница 35: ...35...