– 18 –
Control TCO
The control TCO is one shot with a trip temperature
of 280°F. If the control TCO trips, no voltage will be
supplied to the control or components. Look for
control or wire damage and replace as necessary.
To remove the control TCO:
1. Remove the inner door panel on PermaTuf tub
models or the outer door panel on stainless steel
tub models. (See
Inner Door Panel (PermaTuf Tub
Models)
or
Outer Door Panel (Stainless Steel Tub
Models).)
2. Fold back the vinyl shield that covers the control
board cover.
Caution: The vinyl shield must cover the control
board cover before installing the inner door panel.
Vinyl Shield
3. Remove the single Phillips-head screw that
holds the control TCO to the control board cover.
3. Disconnect the 2 wires from the detergent/rinse
module.
(Continued next page)
Electrical Grade
Silicone Grease
Note: When replacing the control TCO, splice a new
thermostat into the harness using connectors and
procedures approved for damp/wet conditions.
Control Board
The control board is located under the cover
beneath the inner door panel.
To remove the control board:
1. Remove the control TCO. (See
Control TCO.)
2. Detach the tape from the control board cover,
then pull the cover off the control board
housing.
Disconnect