Installation
Valve with Detachable Pipe Connection Elements
Installation
Notes on Installation
The standard installation position of the valve is upright and in no case more than 15
degrees to the vertical. However, care must be taken to ensure that the valve housing
and the pipe system can drain properly.
To prevent damage, make sure that
•
the valve is installed in the pipe system free of tension and
•
no foreign materials (e.g. tools, bolts, lubricants) are left in the system.
Valve with Detachable Pipe Connection Elements
This section describes the procedure to fit the valve.
CAUTION
Liquids in pipes
Danger of injury due to liquid spraying out
Therefore, before releasing any pipe connections or clamp joints: drain the pipe and,
if necessary, clean or rinse it.
Separate the pipe section in which the valve is to be fitted from the rest of the piping
system to prevent product entering again.
Carry out the following steps:
Fit valves with detachable pipe connection elements – using suitable connection
fittings – directly into the pipe system.
Done