Electrical Connections and Commissioning
Adjusting the Position Detecting Devices
38
Operating Instructions · VARIVENT
®
Mixproof Valve M-C/2.0
Edition 2018-10-04
2.
Turn setting screw (1) of the sensor S2, until light emitting D2 at the interface top
shines yellow.
3.
Move sensor using the setting screw (1) in the direction of the upper switching edge
(4) of the switching range (3) until the diode turnes off.
Setting the
switch point
Carry out the following steps:
1.
Setting the switchpoint in downward position, 1 anti-clockwise rotation.
Light emitting diode D2 at the interface top shines yellow.
2.
Tighten the locking screw (2).
3.
Deactivate solenoid valve Y1.
Valve disk moves into the nonactuated position.
LED B yellow turnes off and LED A green switches on.
4.
If you are ready put on the hood.
Done
Содержание VARIVENT 24/7 PMO
Страница 69: ...Maintenance 69 Assembling 2 Hold carrier sleeve at Z using a hook spanner...
Страница 81: ...1 Spare parts list double seat valve M C 2 0 Fig 1 Spare parts list double seat valve M C 2 0 04 10 2018 81...
Страница 85: ...1 Spare parts list Switch bar T VIS A 15 Fig 1 Spare parts list Switch bar T VIS A 15 04 10 2018 85...
Страница 87: ...1 Spare parts list Switch bar T VIS M 15 Fig 1 Spare parts list Switch bar T VIS M 15 04 10 2018 87...
Страница 89: ...1 Dimension sheet double seat valve M C 2 0 Fig 1 Dimension sheet double seat valve M C 2 0 04 10 2018 1...