Maintenance
Prior to dismantling the Valve
5
4
Operating Instructions · VARIVENT
®
Mixproof Valve M-C/2.0
Edition 2018-10-04
Maintenance Intervals
To ensure the highest operational reliability of the valves, all wearing parts should be
replaced at longer intervals.
The actual maintenance intervals can only be determined by the user since they depend
on the operating conditions, for instance:
•
daily period of use,
•
switching frequency,
•
type and temperature of the product,
•
type and temperature of the cleaning solution,
•
ambient conditions.
Prior to dismantling the Valve
Requirement
Make sure that during maintenance and repair work no process is in operation in the
area concerned.
Carry out the following steps:
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean or rinse
them.
2.
Shut off the control air supply.
3.
Disconnect the power supply.
4.
For a better access take the valve, with housing and housing connections if
possible, out of the pipe section.
Done
Maintenance Intervals
Applications
Maintenance Intervals
(guideline values)
Media at temperatures of
60 °C to 130 °C
approx. every 3 months
Media at temperatures of
< 60 °C
approx. every 12 months
Содержание VARIVENT 24/7 PMO
Страница 69: ...Maintenance 69 Assembling 2 Hold carrier sleeve at Z using a hook spanner...
Страница 81: ...1 Spare parts list double seat valve M C 2 0 Fig 1 Spare parts list double seat valve M C 2 0 04 10 2018 81...
Страница 85: ...1 Spare parts list Switch bar T VIS A 15 Fig 1 Spare parts list Switch bar T VIS A 15 04 10 2018 85...
Страница 87: ...1 Spare parts list Switch bar T VIS M 15 Fig 1 Spare parts list Switch bar T VIS M 15 04 10 2018 87...
Страница 89: ...1 Dimension sheet double seat valve M C 2 0 Fig 1 Dimension sheet double seat valve M C 2 0 04 10 2018 1...