09
430
-08
.2
01
6-
Gb
5
Disassembly
3.2 Disconnecting the electrical connections and the components
X
Do not damage any cables and components.
Damaged parts must be repaired or replaced immediately.
¾
Remove the connection of the oil sump heater at the terminal box, the oil sump heater can remain in the compressor
housing.
¾
Remove the terminal box cover (4 hexagon head screws, if available).
¾
Loosen the electrical connections on the terminal board and on the motor protection device.
¾
Remove the terminal box (4 hexagon head screws M6, AF10).
¾
Remove the terminal board (8 cylinder head screws M10, AF8).
¾
Remove the electrical lines from the underside of the terminal board (6 hexagon head screws M6, AF10).
Содержание Bock HGX2 CO2 T Series
Страница 23: ...09430 08 2016 Gb 23 ...