background image

5

About Your Heat Pump

 

(AZ65 only)

Heat pumps can save money by removing heat from the outside 

DLU³HYHQZKHQWKHRXWVLGHWHPSHUDWXUHLVEHORZIUHH]LQJ³DQG

releasing that heat indoors.
To get the best performance from your heat pump, don’t 

change the room thermostat very often. Raising the heat setting 

2–3 degrees will cause the Zoneline to use its electric heating 

elements in order to reach the new temperature setting quickly.

There is a 3-minute minimum compressor run time at any setting 

to prevent short cycling.
The fans start before the compressor and stop after the 

compressor cycles off.
When the outdoor temperature is lower than 25°F, heat is 

provided by the electric heater instead of by the heat pump.
The electric heating elements use much more electricity than 

heat pumps and cost more to operate.

About the controls on your Zoneline. 

Controls

Temp Control

The temp control is used to maintain the room temperature. The 

compressor will cycle on and off to keep the room at the same level  

of comfort. 
Press the + pad to raise the temperature.
Press the - pad to lower the temperature.
NOTE: The display shows the set temperature, not the room 

temperature.

Fan, Mode and Operation Control

)$1³Sets the fan operation for HIGH or LOW.

02'(³&22/³For cooling 

)$1³For fan-only operation 
+($7³For heating

2))³Turns the unit off. Power remains connected to the 

Zoneline. The Freeze/Heat Sentinel features still function if 

active.  See the Freeze/Heat Sentinel section on page 6.

NOTE: The temperature display will flash if the control panel is locked 

(see Control Lock Out section).

86(:$//7(50267$7³ This LED will light up when the unit is 

controlled by a wall thermostat.  See page 7 for details.
NOTE:  When switching between modes, it may take several minutes 

to completely change operation.

Quick Heat Recovery

Activates each time the thermostat is switched from OFF or COOL 

mode to HEAT mode. Electric heaters are energized until the 

thermostat set point is reached. On heat pump models, the heat 

pump operation will resume at the next call for heat.

Control Lock Out

The control panel can be locked out to prevent users from changing 

the operation mode of the unit.
While the unit is in the desired operating mode, press and hold the 

DISPLAY SHOW/HIDE button for 10 seconds to lock the control and 

the desired setting.  Any key press after that will result in the mode 

LED and temperature that was locked ot flash 5 times and then go 

dormat.
To unlock the control lock out feature, press the DISPLAY SHOW/HIDE 

button for 10 seconds to unlock and resume normal operation.

Содержание Zoneline AZ45

Страница 1: ...on Filter 12 Air Filters 13 Installation Instructions Preparation 14 Replacing an Existing Unit 15 Electrical Connection 16 18 Installing the Zoneline 19 20 Optional Drain Kit 21 Troubleshooting Tips...

Страница 2: ...TE We strongly recommend that any servicing be performed by a qualified individual These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards...

Страница 3: ...ar les entrepreneurs et les techniciens doivent tre approuv s en fonction du fluide frigorig ne dont le syst me de climatisation R410A du Zoneline est quip N UTILISEZ PAS d quipements certifi s relati...

Страница 4: ...r servicio llevado a cabo en este equipo lo realice un individuo calificado Los sistemas de acondicionador de aire R410A requieren que los contratistas y t cnicos utilicen herramientas equipamiento y...

Страница 5: ...and Operation Control 1 Sets the fan operation for HIGH or LOW 02 22 For cooling 1 For fan only operation 7 For heating 2 Turns the unit off Power remains connected to the Zoneline The Freeze Heat Sen...

Страница 6: ...trol in the closed position The room air will be filtered and circulated Air Direction To change the air direction remove the room front Remove the 4 louver screws that hold the louver insert in place...

Страница 7: ...onfirm the selection and exit AUX SET mode 6PDUW DQ RROLQJ HDWLQJ Press MODE until a 1 appears in the first digit of the display for Smart Fan cool mode The COOL LED light on the main control will be...

Страница 8: ...t of the display for Freeze Sentinel mode The COOL LEDlight on the main control will be on Press MODE again to change to the Heat Sentinel The HEAT LEDlight on the main control will be on Press the pa...

Страница 9: ...The second digit of the display will be between 0 and 7 depending on the limit you want to set The chart shows the limits available Press AUX SET to confirm your selection and exit AUX SET mode or pre...

Страница 10: ...stance heat To set All Electric Heat option press MODE until an 8 appears in the first digit of the display Press the or pad to set this switch to OFF or ON This is shown in the second digit of the di...

Страница 11: ...thermostat IMPORTANT The Zoneline thermostat connections provide 24 V AConly If using a digital electronic wall thermostat you must set it to the 24 V ACsetting See the Installation Instructions for...

Страница 12: ...NT This filter is not removable Trying to remove this filter will damage the unit Use a vacuum to remove debris from the filter Use a damp rag to wipe down the filter and surrounding area after vacuum...

Страница 13: ...lters Vacuum off the heavy soil Run water through the filters from the back side Dry thoroughly before replacing NOTE The air filters are interchangeable and will fit in either the right or left side...

Страница 14: ...kWLPHQW HQ DOXPLQLXP SHXYHQW SRVHU GHV SUREOqPHV SDUWLFXOLHUV FRQVXOWH XQ pOHFWULFLHQ TXDOL p Quand votre appareil est en position OFF arr t il reste de la ten sion dans les commandes lectriques D bra...

Страница 15: ...area as calculated by ASHRAE See the Architects and Engineers Data Manual for more detailed information Any vertical deflectors in the existing rear grille should be removed to decrease condenser air...

Страница 16: ...or leakage current detection device on the power cord except direct connect Be sure to select the correct cord for your installation Branch Circuit and Proper GE Power Cord Unit Amperage Rating with...

Страница 17: ...La conexi n de este producto de 265 voltios de CA a un circuito derivado DEBE realizarse mediante una conexi n directa de acuerdo a las indicaciones del NEC El c digo no permite enchufar esta unidad a...

Страница 18: ...Fan 3 80 3 11 KW Low Fan 230 208 Volt Power Supply Kits 1 Circuit Protective Device Heater Wattage 230 208 Volts RAK315D RAK320D RAK330D 15 Amp Time Delay Fuse or Breaker 20 Amp Time Delay Fuse or Bre...

Страница 19: ...the room side of the case The RAB71A B series wall cases are already insulated NOTE For installation with a subbase or duct adapter see the instructions packed with those kits 2 PREPARE THE UNIT Care...

Страница 20: ...op 1 then pushing it in at the bottom 2 NOTE There are several extra holes in the unit side flanges for installation in wall cases other than GE To avoid damaging the flange insulation the installer s...

Страница 21: ...walls we recommend the use of RAD10 Drain Kit External Drain See the Installation Instructions in the RAD10 kit Internal Drain See the Installation Instructions in the RAD10 kit Type A screw for metal...

Страница 22: ...ug interrupter device is tripped or the box near the plug If the RESET button will not stay engaged discontinue use of the Zoneline and contact a qualified service technician Zoneline does not cool In...

Страница 23: ...desired NOTE Use of this option will result in increased energy consumption The unit is not The Smart Fan Auxiliary See Smart Fan Cooling Heating on page 5 blowing out air Controls may be set to cycl...

Страница 24: ...set up to be in continuous fan the indoor fan will run regardless if the unit may be cooling or heating Other times the fan will run longer than the heating cooling cycle or kick on occasionally This...

Страница 25: ...RGL FDWLRQ After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 432 2737 Rea...

Страница 26: ...Please place in envelope and mail to Please place in envelope and mail to Veuillez mettre dans une enveloppe et envoyez 26 Product Registration...

Страница 27: ...her rights which vary from state to state or province to province To know what your legal rights are consult your local state or provincial consumer affairs office or your state s Attorney General War...

Страница 28: ...hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their...

Отзывы: