background image

Accessories

6P

A1

A1E

A3

A4

Calibrate

CDT

CDP

**DS

*DT

*DW

E

EL/P

K/P

L1

L2

L3

L4

*LNP

P1

Q2

Q3

Q7

R1-1

R1-3

R15

*R15D

R16

R50

S5P

S12P

S13P

T

T3/W3

U

UMD

VI

W

YEN

MSTD

MEXE

MCON

MSEN

MSPE

MPSG

2

2

2

2

2

2

2

2

3

3

2

2

2

2

2

2

2

2

2

2

2

2

Group Packages

2

2

3

Standard Accessory included in the group package.
Optional Accessory not included but can be added to group package.
Optional Accessory. Can not be used with accessory having the same symbol.
N/A
Denotes an Accessory with 2 circuits as a standard.
Denotes an Accessory with 3 circuits as a standard.

* Delayed Transition Units Only.
** Optional for 40-400 Amp

Page 5

PB

-5066

Z

enith

ZTS

Series Accessory Group Matrix

Z

enith

ZTS

Series Accessory De

nitions

6P

Microprocessor activated test switch (Momentary)

6A

Hardwired test switch (Maintained)

6AP

Microprocessor activated test switch (Maintained)

6B

Hardwired test switch (Maintained Auto - Momentary Test) 
Key operated

6C

Hardwired test switch (Maintained Auto - Maintained Test) 
Key operated

A

1

Auxiliary Contact S.P.D.T. - Normal (Source 1) Failure

A

1E

Auxiliary Contact S.P.D.T. - Emergency (Source 2) Failure

A

3

Auxiliary Contact - closed in emergency (Source 2) Additional

 

available (10 max.) on ZTS Series and need to be specified

A

4

Auxiliary Contact - closed in normal (Source 1) Additional available

 

(10 max.) on ZTS Series and need to be specified

AB

3

Auxiliary Contact - closed in bypass emergency (Source 2) (S.P.D.T.)
(Standard up to 400A) Additional available (10 max.) on ZBTS

 

Series and need to be specified

AB

4

Auxiliary Contact - closed in bypass normal (Source 1) (S.P.D.T.)
(Standard up to 400A) Additional available (10 max.) on

 

ZBTS

 

Series

 

and need to be specified

CALIBRATE

Microprocessor activated calibration feature

CDP

Programmable exerciser daily, 7/14/28/365 days user-selectable,

 

with or without load

CDT

Exerciser no load timer

CTAP

Chicago transfer alarm panel mounted in door of enclosure.

 

Includes 3 aux. contacts and fuse.

DS

Disconnect Switch. Disconnects source voltage to transfer

 

power 

panel.

DT

 

(DELAYED

 

TRANSITION

 

ONLY)

Time Delay from Neutral Switch position to Source 1 on retransfer

 

DW

 

(DELAYED

 

TRANSITION

 

ONLY)

Time Delay from Neutral Switch position to Source 2 on retransfer

 

E

Engine Start Relay

ECM

Ethernet Communication Adapter. Requires MCM

 

(Modbus) Accessory.

 

EL

/P

Event log of last 16 events

F

Fan contact, closed when engine runs.

HT

(1)(2)

Heater and Thermostat 208/240V (1) 380/600V (2) mounted and
interwired in enclosure. (requires larger enclosure for 40-200A)

K

Frequency Meter (Analog) - Door mounted

K

/P

Frequency Indication on the controller

LNP

Center-off position LCD-Indicator

L

1

LED

light indicates Switch in Source 2 position

L

2

LED

light indicates Switch in Source 1 position

L

3

LED

light indicates Source 1 available

L

4

LED

light indicates Source 2 available

Z

enith

ZTS

Series Accessory De

nitions 

(cont.)

Содержание Zenith ZTS Series

Страница 1: ...GE Digital Energy Power Quality Zenith ZTS Series Low Voltage Automatic and Manual Transfer Switches ...

Страница 2: ...ed Transition Bypass Switches 100 4000 Amps All ZTS products meet or exceed industry requirements allowing specification and installation confidence UL 1008 listed through 480 VAC CSA C22 2 No 178 listed through 600 VAC IEC 947 6 1 listed through 480 VAC Codes and Standards NFPA 70 99 101 110 IEEE 446 241 602 NEC 517 700 701 702 NEMA ICS 10 Controls tested in accordance with IEEE 472 ANSI C37 90A EN...

Страница 3: ...ounted on a specially formed panel Logic devices including microprocessor control auxiliary time delays and special accessory equipment are assembled on the door for ease of maintenance and separation from the power section They are connected with a numbered wiring harness equipped with a disconnect plug that allows isolation of the control panel for maintenance ZTS Series Method of Operation When...

Страница 4: ...ommunications allowing connectivity with other ATS s paralleling switchgear and SCADA systems Time tested synchronous logic automatically measures phase angle and frequency allowing disturbance free transfer Unsurpassed statistical ATS System monitoring available in real time T3 W3 elevator pre signal Automatically bypassed if the selected source fails minimizing time an elevator is without power ...

Страница 5: ...es and need to be specified AB3 Auxiliary Contact closed in bypass emergency Source 2 S P D T Standard up to 400A Additional available 10 max on ZBTS Series and need to be specified AB4 Auxiliary Contact closed in bypass normal Source 1 S P D T Standard up to 400A Additional available 10 max on ZBTS Series and need to be specified CALIBRATE Microprocessor activated calibration feature CDP Programm...

Страница 6: ... 1 R1 3 Over Voltage sensing for normal Source 1 single R1 1 or three R1 3 phase R15 R15D Load Shed Should Source 2 become overloaded an external signal can be given to ATS to transfer to the Neutral or dead Normal Source 1 position R16 Phase rotation sensing of Normal Source 1 and Emergency Source 2 R50 In Phase monitor between Normal Source 1 and Emergency Source 2 to allow transfer S5P Micropro...

Страница 7: ...14 HxWxD For 260 400A the enclosure is 66 x 24 x 19 75 HxWxD For 600A the enclosure is 74 x 40 x 19 75 HxWxD For certified drawings please contact the GE factory Application Notes NOTES Line and load terminals are located in rear and arranged for bus bar connection Terminal lugs are available as an accessory Contact the GE factory for more details 1 Special terminal lugs and neutral bars are availa...

Страница 8: ...0 1 3 wire 50 5 7 480 1 2 wire 60 5 8 254 440 3 4 wire 60 6 0 575 3 3 wire 60 6 1 347 600 3 4 wire 60 6 3 575 1 2 wire 60 7 0 277 480 3 4 wire 60 7 1 277 1 2 wire 60 7 4 266 460 3 4 wire 60 7 5 460 3 3 wire 60 8 2 380 1 2 wire 50 9 0 240 416 3 4 wire 60 9 1 220 380 3 4 wire 60 9 2 220 380 3 4 wire 50 9 3 240 416 3 4 wire 50 9 7 380 3 3 wire 60 Note Operating voltage must be specified at time of or...

Отзывы: